4WREE10EA50-2X/G24K31/A1V 4WREE10E25-2X/G24K31/F1V 4WREE10E75-2X/G24K31/F1V German made Rexroth hydraulic directional proportional solenoid valve
4WREE10EA50-2X/G24K31/A1V
4WREE10E25-2X/G24K31/F1V
4WREE10E75-2X/G24K31/F1V
| Attribute | Value |
|---|---|
| Processing & Customization | Yes |
| Type | Proportional valve |
| Material | Cast steel |
| Brand | REXROTH |
| Scope of Application | Hydraulic system |
| Product Alias | Proportional directional valve |
| Applicable Medium | Oil products |
| Applicable Temperature | Normal temperature (℃) |
| Nominal Pressure | Normal pressure (MPa) |
| Nominal Diameter | 6-way diameter (mm) |
| Installation type | Threaded installation |
| Operating Temperature | Room temperature |
| Type (channel location) | Straight through type |
4WRZ10W9-85-7X/6EG24N9K4/D3M
4WRZ10EA25-7X/6EG24N9K4/M
4WRZ10W9-85-7X/6EG24N9EK4/M
... [additional models truncated for brevity]
A: The spool returns to its neutral position via internal springs, ensuring safe system shutdown or holding position (depending on the neutral configuration).
A: Yes, it works with Rexroth's VT series amplifiers (e.g., VT-VSPA1-1-1X) or third-party amplifiers supporting 4-20 mA/0-10 V signals.
A: Use the amplifier's dead band adjustment feature or the valve's built-in trimmer (if available) to minimize dead band for smoother control.
A: Yes, when paired with a load-sensitive pump, it optimizes energy efficiency by matching flow to the load demand.
A: Perform routine inspection every 6 months or 2000 operating hours; full maintenance (disassembly, cleaning) is recommended every 2-3 years or as per system conditions.