4WREE10V25-2X/G24K31/F1V 4WREE10W50-2X/G24K31/F1V 4WREE10E75-2X/G24K31/A1V Hydraulic valve German Rexroth proportional directional solenoid valve
Price:
2
MOQ:
1
Delivery Time:
2 weeks
Brand:
Rexroth
Product Description
Rexroth Proportional Directional Solenoid Valve
Product Models
4WREE10V25-2X/G24K31/F1V
4WREE10W50-2X/G24K31/F1V
4WREE10E75-2X/G24K31/A1V
4WREE10W50-2X/G24K31/F1V
4WREE10E75-2X/G24K31/A1V
Product Specifications
| Attribute | Value |
|---|---|
| Processing & Customization | Yes |
| Type | Proportional valve |
| Material | Cast steel |
| Brand | REXROTH |
| Scope of Application | Hydraulic system |
| Product Alias | Proportional directional valve |
| Applicable Medium | Oil products |
| Applicable Temperature | Normal temperature (℃) |
| Nominal Pressure | Normal pressure (MPa) |
| Nominal Diameter | 6-way diameter (mm) |
| Installation type | Threaded installation |
| Operating Temperature | Room temperature |
| Type (channel location) | Straight through type |
Product Image
Compatible Models
4WRZ10E1-85-7X/6EG24N9EK4/D3M
4WRZ10E1-85-7X/6EG24N9EK4/M
4WRZ10E1-85-7X/6EG24N9K4/D3M
4WRZ10E1-85-7X/6EG24N9K4/M
4WRZ10E1-50-7X/6EG24N9TK4/D3M
4WRZ10E1-85-7X/6EG24N9TK4/D3M
4WRZ10E3-85-7X/6EG24N9TK4/M
4WRZ10E1-50-7X/6EG24N9EK4/M
4WRZ10E85-7X/6EG24N9ETK4/D3M
4WRZ10E1-50-7X/6EG24N9ETK4/D3M
4WRZ10E1-50-7X/6EG24N9ETK4/M
4WREE10WA75-2X/G24K31/F1V
4WREE10WA50-2X/G24K31/F1V
4WREE10WA25-2X/G24K31/F1V
4WREE10EA75-2X/G24K31/F1V
4WREE10EA25-2X/G24K31/F1V
4WREE10W1-75-2X/G24K31/F1V
4WRZ10E50-7X/6EG24N9TK4/D3M
4WRZ10E85-7X/6EG24N9K4/D3M
4WRZ10E85-7X/6EG24N9EK4/M
4WRZ10E85-7X/6EG24N9EK4/D3M
4WRZ10E85-7X/6EG24N9TK4/M
4WRZ10E1-25-7X/6EG24N9EK4/M
4WRZ10E85-7X/6EG24N9TK4/D3M
4WRZ10E1-25-7X/6EG24N9K4/D3M
4WRZ10E1-25-7X/6EG24N9EK4/D3M
4WRZ10E1-50-7X/6EG24N9K4/D3M
4WRZ10E85-7X/6EG24N9K4/M
4WRZ10E85-7X/6EG24N9ETK4/M
4WRZ10E1-50-7X/6EG24N9K4/M
4WRZ10E1-50-7X/6EG24N9EK4/D3M
4WREE10W1-25-2X/G24K31/F1V
4WREE10W1-50-2X/G24K31/F1V
4WREE10EA50-2X/G24K31/F1V
4WRZ10E50-7X/6EG24N9TK4/M
4WRZ10E1-25-7X/6EG24N9K4/M
4WRZ10E1-50-7X/6EG24N9TK4/M
4WREE10W75-2X/G24K31/F1V
4WREE10V50-2X/G24K31/F1V
4WREE10W1-75-2X/G24K31/A1V
4WREE10W1-25-2X/G24K31/A1V
4WREE10W75-2X/G24K31/A1V
4WREE10W50-2X/G24K31/A1V
4WREE10W25-2X/G24K31/A1V
4WREE10V75-2X/G24K31/A1V
4WREE10V50-2X/G24K31/A1V
4WREE10E1-25-2X/G24K31/A1V
4WREE10E1-50-2X/G24K31/A1V
4WREE10EA75-2X/G24K31/A1V
4WREE10WA50-2X/G24K31/A1V
4WREE10E50-2X/G24K31/F1V
4WREE10V75-2X/G24K31/F1V
4WREE10WA75-2X/G24K31/A1V
4WREE10W25-2X/G24K31/F1V
4WREE10V25-2X/G24K31/A1V
4WREE10EA50-2X/G24K31/A1V
4WREE10E25-2X/G24K31/F1V
4WREE10E75-2X/G24K31/F1V
4WREE10E1-25-2X/G24K31/F1V
4WREE10E1-50-2X/G24K31/F1V
4WREE10E1-75-2X/G24K31/F1V
4WREE10V25-2X/G24K31/F1V
4WREE10W50-2X/G24K31/F1V
4WREE10E75-2X/G24K31/A1V
4WREE10E1-75-2X/G24K31/A1V
4WREE10WA25-2X/G24K31/A1V
4WREE10EA25-2X/G24K31/A1V
4WRZ10E1-85-7X/6EG24N9EK4/M
4WRZ10E1-85-7X/6EG24N9K4/D3M
4WRZ10E1-85-7X/6EG24N9K4/M
4WRZ10E1-50-7X/6EG24N9TK4/D3M
4WRZ10E1-85-7X/6EG24N9TK4/D3M
4WRZ10E3-85-7X/6EG24N9TK4/M
4WRZ10E1-50-7X/6EG24N9EK4/M
4WRZ10E85-7X/6EG24N9ETK4/D3M
4WRZ10E1-50-7X/6EG24N9ETK4/D3M
4WRZ10E1-50-7X/6EG24N9ETK4/M
4WREE10WA75-2X/G24K31/F1V
4WREE10WA50-2X/G24K31/F1V
4WREE10WA25-2X/G24K31/F1V
4WREE10EA75-2X/G24K31/F1V
4WREE10EA25-2X/G24K31/F1V
4WREE10W1-75-2X/G24K31/F1V
4WRZ10E50-7X/6EG24N9TK4/D3M
4WRZ10E85-7X/6EG24N9K4/D3M
4WRZ10E85-7X/6EG24N9EK4/M
4WRZ10E85-7X/6EG24N9EK4/D3M
4WRZ10E85-7X/6EG24N9TK4/M
4WRZ10E1-25-7X/6EG24N9EK4/M
4WRZ10E85-7X/6EG24N9TK4/D3M
4WRZ10E1-25-7X/6EG24N9K4/D3M
4WRZ10E1-25-7X/6EG24N9EK4/D3M
4WRZ10E1-50-7X/6EG24N9K4/D3M
4WRZ10E85-7X/6EG24N9K4/M
4WRZ10E85-7X/6EG24N9ETK4/M
4WRZ10E1-50-7X/6EG24N9K4/M
4WRZ10E1-50-7X/6EG24N9EK4/D3M
4WREE10W1-25-2X/G24K31/F1V
4WREE10W1-50-2X/G24K31/F1V
4WREE10EA50-2X/G24K31/F1V
4WRZ10E50-7X/6EG24N9TK4/M
4WRZ10E1-25-7X/6EG24N9K4/M
4WRZ10E1-50-7X/6EG24N9TK4/M
4WREE10W75-2X/G24K31/F1V
4WREE10V50-2X/G24K31/F1V
4WREE10W1-75-2X/G24K31/A1V
4WREE10W1-25-2X/G24K31/A1V
4WREE10W75-2X/G24K31/A1V
4WREE10W50-2X/G24K31/A1V
4WREE10W25-2X/G24K31/A1V
4WREE10V75-2X/G24K31/A1V
4WREE10V50-2X/G24K31/A1V
4WREE10E1-25-2X/G24K31/A1V
4WREE10E1-50-2X/G24K31/A1V
4WREE10EA75-2X/G24K31/A1V
4WREE10WA50-2X/G24K31/A1V
4WREE10E50-2X/G24K31/F1V
4WREE10V75-2X/G24K31/F1V
4WREE10WA75-2X/G24K31/A1V
4WREE10W25-2X/G24K31/F1V
4WREE10V25-2X/G24K31/A1V
4WREE10EA50-2X/G24K31/A1V
4WREE10E25-2X/G24K31/F1V
4WREE10E75-2X/G24K31/F1V
4WREE10E1-25-2X/G24K31/F1V
4WREE10E1-50-2X/G24K31/F1V
4WREE10E1-75-2X/G24K31/F1V
4WREE10V25-2X/G24K31/F1V
4WREE10W50-2X/G24K31/F1V
4WREE10E75-2X/G24K31/A1V
4WREE10E1-75-2X/G24K31/A1V
4WREE10WA25-2X/G24K31/A1V
4WREE10EA25-2X/G24K31/A1V
Frequently Asked Questions
Q: Can the 4WRZ10 be mounted in a manifold?
A: Yes, it is compatible with manifold mounting (ISO 4401 manifolds) for space-saving and centralized hydraulic system designs.
Q: How to prevent leakage at the hydraulic connections?
A: Use O-rings or flat gaskets (compatible with hydraulic fluid) and ensure proper port cleaning before assembly; avoid over-tightening bolts.
Q: What is the correct way to connect the drain port (if applicable)?
A: The drain port (marked "R" or "L") should be connected to the tank with minimal backpressure (< 3 bar) to ensure proper solenoid cooling and seal lubrication.
Q: Does the 4WRZ10 require a bypass valve for startup?
A: A bypass valve is not mandatory but recommended to flush the system before commissioning, removing contaminants that may damage the valve.
Q: How to verify the electrical wiring of the 4WRZ10?
A: Check for correct polarity (solenoid +/-, feedback signals), continuity, and insulation resistance (> 1 MΩ) using a multimeter; refer to the wiring diagram in the manual.