4WREE6E08-2X/G24K31/F1V 4WREE6V32-2X/G24K31/F1V 4WREE6W16-2X/G24K31/F1V German made Rexroth hydraulic proportional hydraulic directional solenoid valve
Price:
2
MOQ:
1
Delivery Time:
2 weeks
Brand:
Rexroth
Product Description
Rexroth Proportional Hydraulic Directional Solenoid Valve
Product Models
4WREE6E08-2X/G24K31/F1V
4WREE6V32-2X/G24K31/F1V
4WREE6W16-2X/G24K31/F1V
Product Specifications
| Attribute | Value |
|---|---|
| Processing & Customization | Yes |
| Type | Proportional valve |
| Material | Cast steel |
| Brand | REXROTH |
| Scope of Application | Hydraulic system |
| Applicable Medium | Oil products |
| Applicable Temperature | Normal temperature (℃) |
| Nominal Pressure | Normal pressure (MPa) |
| Nominal Diameter | 6-way diameter (mm) |
| Installation type | Threaded installation |
| Operating Temperature | Room temperature |
| Type (channel location) | Straight through type |
Compatible Models
4WREE6V16-2X/G24K31/F1V
4WREE6WA32-2X/G24K31/F1V
4WREE6W32-2X/G24K31/F1V
4WREE6W1-32-2X/G24K31/F1V
4WREE6E08-2X/G24K31/F1V
4WREE6V32-2X/G24K31/F1V
4WREE6W16-2X/G24K31/F1V
4WREE6EA08-2X/G24K31/F1V
4WREE6EA32-2X/G24K31/F1V
4WREE6WA08-2X/G24K31/F1V
4WREE6WA16-2X/G24K31/F1V
4WREE10E25-2X/G24K31/A1V
4WREE6W08-2X/G24K31/F1V
4WREE6W1-08-2X/G24K31/F1V
4WREE6W1-16-2X/G24K31/F1V
4WREE6V08-2X/G24K31/F1V
Frequently Asked Questions
Q: What should be done if the valve is noisy during operation?
A: Check for cavitation (low inlet pressure), loose mounting, air in the system, or worn internal components; address the root cause (e.g., increase inlet pressure, bleed air).
Q: How to prevent contamination of the 4WRZ10?
A: Use high-quality hydraulic fluid, install proper filters (10 μm), regularly replace filters, and keep the system clean during maintenance.
Q: Can worn spools be repaired, or must they be replaced?
A: Minor wear can be polished (if within tolerance), but significant wear (e.g., scoring, excessive clearance) requires spool replacement with genuine Rexroth parts.
Q: Why does the valve drift from its set position?
A: Drift may result from unstable input signals, temperature changes, worn springs, or a faulty position feedback system; calibrate the valve and check the controller.
Q: How to check for internal leakage in the 4WRZ10?
A: Measure the flow rate from the T port when the valve is in neutral position; excessive flow (beyond Rexroth's specifications) indicates internal leakage.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location
Nan'an, Fujian Province, China
Contact Person
liyun