Model Series PV7-1X/10-14RE01MC0-16, PV7-1X/16-20RE01MC0-16, PV7-2X/20-25RE01MC0-16 (typical models)
Displacement per Revolution 10–25 cm³/rev (varies by specific model)
Maximum Operating Pressure 210 bar (continuous), 250 bar (peak)
Maximum Speed 1800–3600 rpm (depends on displacement and fluid viscosity)
Minimum Speed 600 rpm (ensures stable operation)
Fluid Medium Mineral oil-based hydraulic fluid (ISO VG 32/46/68 recommended)
Fluid Temperature Range -20 °C to +80 °C (operation); -40 °C to +90 °C (storage)
Viscosity Range 10–1000 mm²/s (operation); 2–1500 mm²/s (start-up)
Volumetric Efficiency ≥90% (at rated pressure and speed)
Total Efficiency ≥80% (at rated working condition)
Noise Level ≤65 dB(A) (at 1 m distance under rated operation)
Suction Pressure -0.8 bar to +1 bar (absolute pressure: 0.2–1.1 bar)
Mounting Type Flange mounting (ISO 3019-2 standard), foot mounting (optional)
Shaft Connection Splined shaft (ISO 4162 standard) or keyed shaft (customizable)
Seal Type Viton® or NBR shaft seals (resistant to high temperature and oil)
Inlet/Outlet Port BSPP, BSPT or SAE thread (port size matches displacement)
Weight 8–15 kg (varies by model and configuration)

PV7-1X/40-45RE37MC0-16-P90
PV7-1X/25-30RE01MC0-16-P100Q38
PV7-1X/100-150RE07MC0-08-A464
PV7-1X/100-118RE07MD0-16
PV7-1X/10-14RE01MN0-16
PV7-1X/40-45RE37MC5-16
PV7-1X/100-118RE07MC5-16
PV7-1X/25-30RE01KC3-16
PV7-1X/10-20RE01MC5-10WG
PV7-1X/25-30RE01MW0-16
PV7-1X/16-20RE01MD3-16
PV7-1X/16-20RE01MC0-16-P110
PV7-1X/40-45RE37KD0-16-C3.1
PV7-1X/63-71RE07MC5-16WH
PV7-1X/16-30RE01KC0-08
PV7-1X/10-14RE01MD5-16
PV7-1X/63-71RE07MC6-16
PV7-1X/16-20RE01KD0-16
PV7-1X/10-14RE01MW0-16
PV7-1X/63-71RE07MC0-16-C3.1
PV7-1X/16-30RE01MW0-08WH
PV7-1X/100-150RE07MC0-08-A446
PV7-1X/25-30RE01MC5-16WG
PV7-1X/10-20RE01MC0-10-A497
PV7-1X/100-150RE07KC0-08
PV7-1X/100-150RE07MD5-08
PV7-1X/25-45RE01MC0-08-P25Q50
PV7-1X/40-71RE37MC5-08
PV7-1X/10-14RE01KD0-16
PV7-1X/16-20RE01MC0-16-P120
PV7-1X/100-150RE07MW0-08WH
PV7-1X/16-20RE01MC5-16WG
PV7-1X/10-20RE01MW0-10WH
PV7-1X/63-94RE07KD0-08
PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH
PV7-1X/40-45RE37MC0-16
PV7-1X/63-94RE07MC0-08-P80Q114
PV7-1X/40-45RE37MC5-16WH
PV7-1X/10-14RE01KN0-16
PV7-1X/25-30RE01MC5-16WH
PV7-1X/63-71RE07KC0-16
PV7-1X/10-20RE01MC3-10
PV7-1X/16-20RE01MN0-16
PV7-1X/25-45RE01MW0-08WH
PV7-1X/63-71RE07MN0-16
PV7-1X/63-71RE07KD0-16
PV7-1X/16-20RE01MC8-16
PV7-1X/40-71RE37MW0-08WH
PV7-1X/40-45RE37MD0-16-P50Q36
PV7-1X/40-45RE37MC7-16WG
PV7-1X/100-118RE07MN5-16
PV7-1X/25-45RE01MC7-08WG
PV7-1X/63-71RE07MC7-16
PV7-1X/100-150RE07MC3-08
PV7-1X/40-45RE37KC0-16
PV7-1X/63-94RE07MC5-08
PV7-1X/16-20RE01MC0-16-P60Q26
PV7-1X/16-20RE01MC5-16
PV7-1X/40-71RE37MC5-08WG
PV7-1X/25-45RE01MC7-08
PV7-1X/25-30RE01MW5-16WH
PV7-1X/10-20RE01MD0-10
PV7-1X/63-71RE07MD0-16-Q90
PV7-1X/16-30RE01MC3-08
PV7-1X/100-150RE07MC7-08
PV7-1X/100-118RE07MN0-16
PV7-1X/10-20RE01MC5-10
PV7-1X/25-30RE01MC5-16WH-A234
PV7-1X/100-150RE07MC5-08WH
PV7-1X/25-30RE01MW0-16WH
PV7-1X/10-20RE01MC7-10WH
PV7-1X/25-45RE01MC5-08
PV7-1X/40-45RE37MC8-16
PV7-1X/16-20RE01MW0-16WH
PV7-1X/16-20RE01MC3-16-P50Q25
PV7-1X/100-118RE07KC0-16
PV7-1X/40-71RE37MC5-08WH
PV7-1X/100-118RE07MC6-16
PV7-1X/40-71RE37MC3-08
PV7-1X/40-71RE37MC7-08WH
PV7-1X/10-14RE01MW0-16WH
PV7-1X/10-20RE01MC3-10-A497
PV7-1X/16-20RE01MC3-16
PV7-1X/16-20RE01MC5-16WH
PV7-1X/63-71RE07MC3-06-A460
PV7-1X/16-30RE01MC5-08WH
PV7-1X/10-14RE01MC0-16-P100
PV7-1X/63-94RE07MC5-08WH
PV7-1X/10-14RE01MC3-16
PV7-1X/40-45RE37MD0-16
PV7-1X/100-118RE07MC7-16WH
PV7-1X/25-45RE01MC5-08WH
PV7-1X/16-20RE01MC0-16
PV7-1X/63-71RE07MC5-16WG
PV7-1X/63-71RE07KC3-16
PV7-1X/10-20RE01MC5-10WH
PV7-1X/16-20RE01MC7-16
PV7-1X/10-14RE01MC7-16
PV7-1X/63-94RE07MC0-08
PV7-1X/16-20RE01MC0-16-P100Q29
PV7-1X/25-30RE01MC0-16-P100Q36
PV7-1X/40-45RE37MW5-16WH
PV7-1X/10-14RE01MC0-16-P45
PV7-1X/25-45RE01MN0-08
PV7-1X/25-30RE01MC0-16
PV7-1X/63-94RE07MC0-08-P75
PV7-1X/63-71RE07MW5-16WH
PV7-1X/25-30RE01MC5-16
PV7-1X/40-71RE37MD0-08
PV7-1X/100-150RE07MD0-08
PV7-1X/10-20RE01MC7-10
PV7-1X/10-14RE01MD3-16
PV7-1X/100-118RE07MW0-16WH
PV7-1X/100-118RE07KD0-16
PV7-1X/10-14RE01MC5-16
PV7-1X/63-94RE07MN0-08
PV7-1X/10-14RE01KC0-16
PV7-1X/40-45RE37MC3-16
PV7-1X/40-45RE37MC7-16
PV7-1X/16-20RE01MC0-16-C3.1
PV7-1X/40-45RE37MC0-16-A446
PV7-1X/100-118RE07MW0-16WG
PV7-1X/100-150RE07MC0-08
PV7-1X/63-94RE07MC5-08WG
PV7-1X/16-20RE01KC0-16
PV7-1X/40-55RE37MC0-08-A449
PV7-1X/63-94RE07MD0-08
PV7-1X/16-20RE01MD0-16-Q25
PV7-1X/40-45RE37MD0-16-P50Q39
PV7-1X/63-71RE07MD0-16-Q65
PV7-1X/16-30RE01MC0-08
PV7-1X/40-45RE37MW0-16
PV7-1X/40-71RE37MC0-08
PV7-1X/100-118RE07MW6-16WH
PV7-1X/16-30RE01MC5-08WG
PV7-1X/10-20RE01MC0-10
PV7-1X/63-71RE07MW0-16
PV7-1X/63-94RE07KC0-08
PV7-1X/40-45RE37MC7-16WH
PV7-1X/10-14RE01MC0-16-P60Q15
PV7-1X/63-71RE07KW0-16WG
PV7-1X/100-118RE07KC5-16
PV7-1X/25-30RE01MC7-16
PV7-1X/63-71RE07MC5-16
PV7-1X/25-30RE01KD0-16
PV7-1X/10-14RE01MC5-16WH
PV7-1X/10-20RE01MC0-10-P45
PV7-1X/16-20RE01MW0-16
PV7-1X/16-30RE01MD0-08
PV7-1X/25-45RE01MD0-08

FAQ:

1. Q: What types of hydraulic oil are compatible with PV7 series pumps?
A: It is compatible with mineral-based hydraulic oils, synthetic hydraulic oils, and biodegradable hydraulic oils that meet the requirements of ISO 6743-4 (category HM, HV, HG). The recommended viscosity range is 10–40 mm²/s at operating temperature.

2. Q: How to select the appropriate displacement model of PV7 series pumps?
A: Select according to the system’s required flow rate and working pressure. The displacement range of PV7 series is 4–180 cm³/rev; calculate the flow rate via the formula: Flow (L/min) = Displacement (cm³/rev) × Speed (rpm) ÷ 1000, and match it with the system’s actual flow demand.

3. Q: Can the PV7 series pumps be operated in both clockwise and counterclockwise directions?
A: Most standard PV7 models are designed for fixed rotational direction, but customized models with reversible rotation are available upon request; confirm the rotation direction requirements with the supplier before purchase.

4. Q: What is the recommended oil temperature range for PV7 series pumps during operation?
A: The optimal operating oil temperature is 40–60 °C; the allowable short-term maximum temperature should not exceed 80 °C, and the minimum temperature should not be lower than 10 °C to avoid viscosity abnormalities affecting performance.

5. Q: What causes abnormal noise during the operation of PV7 series pumps?
A: Common causes include insufficient oil suction (such as clogged suction filters, too-small suction pipe diameters), air mixed in the hydraulic oil, excessive oil viscosity, worn pump internal components, or loose mounting bolts.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location Nan'an, Fujian Province, China
Contact Person liyun

Request A Quote

Please check your email address.
Your message must be at least 20 characters.