Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
                                                                                                           
Verified Supplier
Years
Since
Menu

PV7-1X/63-94RE07MC0-08-P80Q114 PV7-1X/40-45RE37MC5-16WH PV7-1X/10-14RE01KN0-16 PV7 series pilot vane pump imported from Germany by Rexroth in stock

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 2 weeks
Brand: Rexroth
Product Description
PV7 Series Pilot Vane Pump

PV7-1X/63-94RE07MC0-08-P80Q114, PV7-1X/40-45RE37MC5-16WH, PV7-1X/10-14RE01KN0-16

PV7 series pilot vane pump imported from Germany by Rexroth in stock

Technical Specifications
Parameter/Property Category Direct-Acting (PV7-A) Series Pilot-Operated (PV7-C/D/N/W) Series Unit Remarks
Model Range PV7-1X/06-10RA01MA0-10, PV7-2X/20-25RA01MA0-10 PV7-1X/14-20RE01MC0-16, PV7-1X/100-118RE07KD0-16 #VALUE! 1X/2X=component series; 06/14/20=frame size
Displacement per Revolution 10-25 14-150 cm³/rev Displacement varies by specific model suffix
Max. Continuous Working Pressure 100 160 bar PV7-A: ≤100 bar; PV7-C/D/N/W: ≤160 bar
Max. Peak Pressure 120 200 bar Short-term (≤5s) overload only
Speed Range 600-2800 600-3600 rpm Higher speed for smaller displacement models
Max. Flow Rate (at 1800 rpm) 36 270 l/min Calculated at rated displacement
Volumetric Efficiency (Rated Condition) ≥90% ≥92% % At 160 bar, 1800 rpm, ISO VG 46 oil
Total Efficiency (Nominal Operation) ≥80% ≥82% % Includes mechanical & volumetric efficiency
Suction Pressure Range 1 -0.8 to +1 bar Absolute pressure: 0.2-1.1 bar
Fluid Compatibility Mineral oil (HLP), synthetic oil (HETG/HEES) Mineral oil (HLP), synthetic oil (HETG/HEES) - Use FKM seals for synthetic fluids
Fluid Viscosity Range 10-1000 (operation); 2-1500 (start-up) 10-1000 (operation); 2-1500 (start-up) mm²/s Optimal: 16-160 mm²/s
Fluid Temperature Range -20 to +80 -20 to +80 °C Storage: -40 to +90 °C
PV7 Series Pilot Vane Pump technical diagram and components
Available Models
  • PV7-1X/63-71RE07MC6-16
  • PV7-1X/16-20RE01KD0-16
  • PV7-1X/10-14RE01MW0-16
  • PV7-1X/63-71RE07MC0-16-C3.1
  • PV7-1X/16-30RE01MW0-08WH
  • PV7-1X/100-150RE07MC0-08-A446
  • PV7-1X/25-30RE01MC5-16WG
  • PV7-1X/10-20RE01MC0-10-A497
  • PV7-1X/100-150RE07KC0-08
  • PV7-1X/100-150RE07MD5-08
  • PV7-1X/25-45RE01MC0-08-P25Q50
  • PV7-1X/40-71RE37MC5-08
  • PV7-1X/10-14RE01KD0-16
  • PV7-1X/16-20RE01MC0-16-P120
  • PV7-1X/100-150RE07MW0-08WH
  • PV7-1X/16-20RE01MC5-16WG
  • PV7-1X/10-20RE01MW0-10WH
  • PV7-1X/63-94RE07KD0-08
  • PV7-1X/63-71RE07MW0-16WH
  • PV7-1X/63-71RE07MC7-16WH
  • PV7-1X/40-45RE37MC0-16
  • PV7-1X/63-94RE07MC0-08-P80Q114
  • PV7-1X/40-45RE37MC5-16WH
  • PV7-1X/10-14RE01KN0-16
  • PV7-1X/25-30RE01MC5-16WH
  • PV7-1X/63-71RE07KC0-16
  • PV7-1X/10-20RE01MC3-10
  • PV7-1X/16-20RE01MN0-16
  • PV7-1X/25-45RE01MW0-08WH
  • PV7-1X/63-71RE07MN0-16
  • PV7-1X/63-71RE07KD0-16
  • PV7-1X/16-20RE01MC8-16
  • PV7-1X/40-71RE37MW0-08WH
  • PV7-1X/40-45RE37MD0-16-P50Q36
  • PV7-1X/40-45RE37MC7-16WG
  • PV7-1X/100-118RE07MN5-16
  • PV7-1X/25-45RE01MC7-08WG
  • PV7-1X/63-71RE07MC7-16
  • PV7-1X/100-150RE07MC3-08
  • PV7-1X/40-45RE37KC0-16
  • PV7-1X/63-94RE07MC5-08
  • PV7-1X/16-20RE01MC0-16-P60Q26
  • PV7-1X/16-20RE01MC5-16
  • PV7-1X/40-71RE37MC5-08WG
  • PV7-1X/25-45RE01MC7-08
  • PV7-1X/25-30RE01MW5-16WH
  • PV7-1X/10-20RE01MD0-10
  • PV7-1X/63-71RE07MD0-16-Q90
  • PV7-1X/16-30RE01MC3-08
  • PV7-1X/100-150RE07MC7-08
  • PV7-1X/100-118RE07MN0-16
  • PV7-1X/10-20RE01MC5-10
  • PV7-1X/25-30RE01MC5-16WH-A234
  • PV7-1X/100-150RE07MC5-08WH
  • PV7-1X/25-30RE01MW0-16WH
  • PV7-1X/10-20RE01MC7-10WH
  • PV7-1X/25-45RE01MC5-08
  • PV7-1X/40-45RE37MC8-16
  • PV7-1X/16-20RE01MW0-16WH
  • PV7-1X/16-20RE01MC3-16-P50Q25
  • PV7-1X/100-118RE07KC0-16
  • PV7-1X/40-71RE37MC5-08WH
  • PV7-1X/100-118RE07MC6-16
  • PV7-1X/40-71RE37MC3-08
  • PV7-1X/40-71RE37MC7-08WH
  • PV7-1X/10-14RE01MW0-16WH
  • PV7-1X/10-20RE01MC3-10-A497
  • PV7-1X/16-20RE01MC3-16
  • PV7-1X/16-20RE01MC5-16WH
  • PV7-1X/63-71RE07MC3-06-A460
  • PV7-1X/16-30RE01MC5-08WH
  • PV7-1X/10-14RE01MC0-16-P100
  • PV7-1X/63-94RE07MC5-08WH
  • PV7-1X/10-14RE01MC3-16
  • PV7-1X/40-45RE37MD0-16
  • PV7-1X/100-118RE07MC7-16WH
  • PV7-1X/25-45RE01MC5-08WH
  • PV7-1X/16-20RE01MC0-16
  • PV7-1X/63-71RE07MC5-16WG
  • PV7-1X/63-71RE07KC3-16
  • PV7-1X/10-20RE01MC5-10WH
  • PV7-1X/16-20RE01MC7-16
  • PV7-1X/10-14RE01MC7-16
  • PV7-1X/63-94RE07MC0-08
  • PV7-1X/16-20RE01MC0-16-P100Q29
  • PV7-1X/25-30RE01MC0-16-P100Q36
  • PV7-1X/40-45RE37MW5-16WH
  • PV7-1X/10-14RE01MC0-16-P45
  • PV7-1X/25-45RE01MN0-08
  • PV7-1X/25-30RE01MC0-16
  • PV7-1X/63-94RE07MC0-08-P75
  • PV7-1X/63-71RE07MW5-16WH
  • PV7-1X/25-30RE01MC5-16
  • PV7-1X/40-71RE37MD0-08
  • PV7-1X/100-150RE07MD0-08
  • PV7-1X/10-20RE01MC7-10
  • PV7-1X/10-14RE01MD3-16
  • PV7-1X/100-118RE07MW0-16WH
  • PV7-1X/100-118RE07KD0-16
  • PV7-1X/10-14RE01MC5-16
  • PV7-1X/63-94RE07MN0-08
  • PV7-1X/10-14RE01KC0-16
  • PV7-1X/40-45RE37MC3-16
  • PV7-1X/40-45RE37MC7-16
  • PV7-1X/16-20RE01MC0-16-C3.1
  • PV7-1X/40-45RE37MC0-16-A446
  • PV7-1X/100-118RE07MW0-16WG
  • PV7-1X/100-150RE07MC0-08
  • PV7-1X/63-94RE07MC5-08WG
  • PV7-1X/16-20RE01KC0-16
  • PV7-1X/40-55RE37MC0-08-A449
  • PV7-1X/63-94RE07MD0-08
  • PV7-1X/16-20RE01MD0-16-Q25
  • PV7-1X/40-45RE37MD0-16-P50Q39
  • PV7-1X/63-71RE07MD0-16-Q65
  • PV7-1X/16-30RE01MC0-08
  • PV7-1X/40-45RE37MW0-16
  • PV7-1X/40-71RE37MC0-08
  • PV7-1X/100-118RE07MW6-16WH
  • PV7-1X/16-30RE01MC5-08WG
  • PV7-1X/10-20RE01MC0-10
  • PV7-1X/63-71RE07MW0-16
  • PV7-1X/63-94RE07KC0-08
  • PV7-1X/40-45RE37MC7-16WH
  • PV7-1X/10-14RE01MC0-16-P60Q15
  • PV7-1X/63-71RE07KW0-16WG
  • PV7-1X/100-118RE07KC5-16
  • PV7-1X/25-30RE01MC7-16
  • PV7-1X/63-71RE07MC5-16
  • PV7-1X/25-30RE01KD0-16
  • PV7-1X/10-14RE01MC5-16WH
Frequently Asked Questions
Q: What is the optimal value range for the Dynamic Flow Compensation Gain Coefficient?
A: Set it between 0.5-2.0; higher values improve response speed for rapid load change scenarios.
Q: How do I calibrate the Nominal Flow Calibration Correction Offset?
A: Calibrate it using a precision flow meter under the pump's rated pressure conditions, adjusting the offset to match measured flow.
Q: What impact does the Flow Stabilization Response Time Constant have?
A: A longer time constant reduces flow fluctuations, making it suitable for unstable load operation environments.
Q: Why is the Minimum Flow Dry-Run Protection Threshold a mandatory setting?
A: It prevents the pump from operating at flow rates too low to maintain adequate lubrication, avoiding dry-run damage.
Q: What is the maximum allowable Flow Step Adjustment Resolution per step?
A: The resolution should not exceed 0.2 L/min per step to ensure gradual, stable flow adjustments.
Operation Protection

Comprehensive protection systems ensure reliable operation and extended service life under demanding industrial conditions.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location Nan'an, Fujian Province, China
Contact Person liyun

Request A Quote

Please check your email address.
Your message must be at least 20 characters.