PV7-1X/63-94RE07MC0-08-P80Q114 PV7-1X/40-45RE37MC5-16WH PV7-1X/10-14RE01KN0-16 PV7 series pilot vane pump imported from Germany by Rexroth in stock
Price:
Negotiable
MOQ:
1
Delivery Time:
2 weeks
Brand:
Rexroth
Product Description
PV7 Series Pilot Vane Pump
PV7-1X/63-94RE07MC0-08-P80Q114, PV7-1X/40-45RE37MC5-16WH, PV7-1X/10-14RE01KN0-16
PV7 series pilot vane pump imported from Germany by Rexroth in stock
Technical Specifications
| Parameter/Property Category | Direct-Acting (PV7-A) Series | Pilot-Operated (PV7-C/D/N/W) Series | Unit | Remarks |
|---|---|---|---|---|
| Model Range | PV7-1X/06-10RA01MA0-10, PV7-2X/20-25RA01MA0-10 | PV7-1X/14-20RE01MC0-16, PV7-1X/100-118RE07KD0-16 | #VALUE! | 1X/2X=component series; 06/14/20=frame size |
| Displacement per Revolution | 10-25 | 14-150 | cm³/rev | Displacement varies by specific model suffix |
| Max. Continuous Working Pressure | 100 | 160 | bar | PV7-A: ≤100 bar; PV7-C/D/N/W: ≤160 bar |
| Max. Peak Pressure | 120 | 200 | bar | Short-term (≤5s) overload only |
| Speed Range | 600-2800 | 600-3600 | rpm | Higher speed for smaller displacement models |
| Max. Flow Rate (at 1800 rpm) | 36 | 270 | l/min | Calculated at rated displacement |
| Volumetric Efficiency (Rated Condition) | ≥90% | ≥92% | % | At 160 bar, 1800 rpm, ISO VG 46 oil |
| Total Efficiency (Nominal Operation) | ≥80% | ≥82% | % | Includes mechanical & volumetric efficiency |
| Suction Pressure Range | 1 | -0.8 to +1 | bar | Absolute pressure: 0.2-1.1 bar |
| Fluid Compatibility | Mineral oil (HLP), synthetic oil (HETG/HEES) | Mineral oil (HLP), synthetic oil (HETG/HEES) | - | Use FKM seals for synthetic fluids |
| Fluid Viscosity Range | 10-1000 (operation); 2-1500 (start-up) | 10-1000 (operation); 2-1500 (start-up) | mm²/s | Optimal: 16-160 mm²/s |
| Fluid Temperature Range | -20 to +80 | -20 to +80 | °C | Storage: -40 to +90 °C |
Available Models
- PV7-1X/63-71RE07MC6-16
- PV7-1X/16-20RE01KD0-16
- PV7-1X/10-14RE01MW0-16
- PV7-1X/63-71RE07MC0-16-C3.1
- PV7-1X/16-30RE01MW0-08WH
- PV7-1X/100-150RE07MC0-08-A446
- PV7-1X/25-30RE01MC5-16WG
- PV7-1X/10-20RE01MC0-10-A497
- PV7-1X/100-150RE07KC0-08
- PV7-1X/100-150RE07MD5-08
- PV7-1X/25-45RE01MC0-08-P25Q50
- PV7-1X/40-71RE37MC5-08
- PV7-1X/10-14RE01KD0-16
- PV7-1X/16-20RE01MC0-16-P120
- PV7-1X/100-150RE07MW0-08WH
- PV7-1X/16-20RE01MC5-16WG
- PV7-1X/10-20RE01MW0-10WH
- PV7-1X/63-94RE07KD0-08
- PV7-1X/63-71RE07MW0-16WH
- PV7-1X/63-71RE07MC7-16WH
- PV7-1X/40-45RE37MC0-16
- PV7-1X/63-94RE07MC0-08-P80Q114
- PV7-1X/40-45RE37MC5-16WH
- PV7-1X/10-14RE01KN0-16
- PV7-1X/25-30RE01MC5-16WH
- PV7-1X/63-71RE07KC0-16
- PV7-1X/10-20RE01MC3-10
- PV7-1X/16-20RE01MN0-16
- PV7-1X/25-45RE01MW0-08WH
- PV7-1X/63-71RE07MN0-16
- PV7-1X/63-71RE07KD0-16
- PV7-1X/16-20RE01MC8-16
- PV7-1X/40-71RE37MW0-08WH
- PV7-1X/40-45RE37MD0-16-P50Q36
- PV7-1X/40-45RE37MC7-16WG
- PV7-1X/100-118RE07MN5-16
- PV7-1X/25-45RE01MC7-08WG
- PV7-1X/63-71RE07MC7-16
- PV7-1X/100-150RE07MC3-08
- PV7-1X/40-45RE37KC0-16
- PV7-1X/63-94RE07MC5-08
- PV7-1X/16-20RE01MC0-16-P60Q26
- PV7-1X/16-20RE01MC5-16
- PV7-1X/40-71RE37MC5-08WG
- PV7-1X/25-45RE01MC7-08
- PV7-1X/25-30RE01MW5-16WH
- PV7-1X/10-20RE01MD0-10
- PV7-1X/63-71RE07MD0-16-Q90
- PV7-1X/16-30RE01MC3-08
- PV7-1X/100-150RE07MC7-08
- PV7-1X/100-118RE07MN0-16
- PV7-1X/10-20RE01MC5-10
- PV7-1X/25-30RE01MC5-16WH-A234
- PV7-1X/100-150RE07MC5-08WH
- PV7-1X/25-30RE01MW0-16WH
- PV7-1X/10-20RE01MC7-10WH
- PV7-1X/25-45RE01MC5-08
- PV7-1X/40-45RE37MC8-16
- PV7-1X/16-20RE01MW0-16WH
- PV7-1X/16-20RE01MC3-16-P50Q25
- PV7-1X/100-118RE07KC0-16
- PV7-1X/40-71RE37MC5-08WH
- PV7-1X/100-118RE07MC6-16
- PV7-1X/40-71RE37MC3-08
- PV7-1X/40-71RE37MC7-08WH
- PV7-1X/10-14RE01MW0-16WH
- PV7-1X/10-20RE01MC3-10-A497
- PV7-1X/16-20RE01MC3-16
- PV7-1X/16-20RE01MC5-16WH
- PV7-1X/63-71RE07MC3-06-A460
- PV7-1X/16-30RE01MC5-08WH
- PV7-1X/10-14RE01MC0-16-P100
- PV7-1X/63-94RE07MC5-08WH
- PV7-1X/10-14RE01MC3-16
- PV7-1X/40-45RE37MD0-16
- PV7-1X/100-118RE07MC7-16WH
- PV7-1X/25-45RE01MC5-08WH
- PV7-1X/16-20RE01MC0-16
- PV7-1X/63-71RE07MC5-16WG
- PV7-1X/63-71RE07KC3-16
- PV7-1X/10-20RE01MC5-10WH
- PV7-1X/16-20RE01MC7-16
- PV7-1X/10-14RE01MC7-16
- PV7-1X/63-94RE07MC0-08
- PV7-1X/16-20RE01MC0-16-P100Q29
- PV7-1X/25-30RE01MC0-16-P100Q36
- PV7-1X/40-45RE37MW5-16WH
- PV7-1X/10-14RE01MC0-16-P45
- PV7-1X/25-45RE01MN0-08
- PV7-1X/25-30RE01MC0-16
- PV7-1X/63-94RE07MC0-08-P75
- PV7-1X/63-71RE07MW5-16WH
- PV7-1X/25-30RE01MC5-16
- PV7-1X/40-71RE37MD0-08
- PV7-1X/100-150RE07MD0-08
- PV7-1X/10-20RE01MC7-10
- PV7-1X/10-14RE01MD3-16
- PV7-1X/100-118RE07MW0-16WH
- PV7-1X/100-118RE07KD0-16
- PV7-1X/10-14RE01MC5-16
- PV7-1X/63-94RE07MN0-08
- PV7-1X/10-14RE01KC0-16
- PV7-1X/40-45RE37MC3-16
- PV7-1X/40-45RE37MC7-16
- PV7-1X/16-20RE01MC0-16-C3.1
- PV7-1X/40-45RE37MC0-16-A446
- PV7-1X/100-118RE07MW0-16WG
- PV7-1X/100-150RE07MC0-08
- PV7-1X/63-94RE07MC5-08WG
- PV7-1X/16-20RE01KC0-16
- PV7-1X/40-55RE37MC0-08-A449
- PV7-1X/63-94RE07MD0-08
- PV7-1X/16-20RE01MD0-16-Q25
- PV7-1X/40-45RE37MD0-16-P50Q39
- PV7-1X/63-71RE07MD0-16-Q65
- PV7-1X/16-30RE01MC0-08
- PV7-1X/40-45RE37MW0-16
- PV7-1X/40-71RE37MC0-08
- PV7-1X/100-118RE07MW6-16WH
- PV7-1X/16-30RE01MC5-08WG
- PV7-1X/10-20RE01MC0-10
- PV7-1X/63-71RE07MW0-16
- PV7-1X/63-94RE07KC0-08
- PV7-1X/40-45RE37MC7-16WH
- PV7-1X/10-14RE01MC0-16-P60Q15
- PV7-1X/63-71RE07KW0-16WG
- PV7-1X/100-118RE07KC5-16
- PV7-1X/25-30RE01MC7-16
- PV7-1X/63-71RE07MC5-16
- PV7-1X/25-30RE01KD0-16
- PV7-1X/10-14RE01MC5-16WH
Frequently Asked Questions
Q: What is the optimal value range for the Dynamic Flow Compensation Gain Coefficient?
A: Set it between 0.5-2.0; higher values improve response speed for rapid load change scenarios.
Q: How do I calibrate the Nominal Flow Calibration Correction Offset?
A: Calibrate it using a precision flow meter under the pump's rated pressure conditions, adjusting the offset to match measured flow.
Q: What impact does the Flow Stabilization Response Time Constant have?
A: A longer time constant reduces flow fluctuations, making it suitable for unstable load operation environments.
Q: Why is the Minimum Flow Dry-Run Protection Threshold a mandatory setting?
A: It prevents the pump from operating at flow rates too low to maintain adequate lubrication, avoiding dry-run damage.
Q: What is the maximum allowable Flow Step Adjustment Resolution per step?
A: The resolution should not exceed 0.2 L/min per step to ensure gradual, stable flow adjustments.
Operation Protection
Comprehensive protection systems ensure reliable operation and extended service life under demanding industrial conditions.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location
Nan'an, Fujian Province, China
Contact Person
liyun