Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
                                                                                                           
Verified Supplier
Years
Since
Menu

PV7-1X/25-30RE01MW5-16WH PV7-1X/10-20RE01MD0-10 PV7-1X/63-71RE07MD0-16-Q90 PV7 blade oil pump, German Rexroth original hydraulic pump, imported in stock

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 2 weeks
Brand: Rexroth
Product Description
PV7 Vane Oil Pump - German Rexroth Original Hydraulic Pump
Product Models
PV7-1X/25-30RE01MW5-16WH
PV7-1X/10-20RE01MD0-10
PV7-1X/63-71RE07MD0-16-Q90
And additional compatible models available
Technical Specifications
Parameter Specification
Model Series PV7-1X/25-30RE01MW5-16WH, PV7-1X/10-20RE01MD0-10, PV7-1X/63-71RE07MD0-16-Q90 (typical models)
Displacement per Revolution 10-25 cm³/rev (varies by specific model)
Maximum Operating Pressure 210 bar (continuous), 250 bar (peak)
Maximum Speed 1800-3600 rpm (depends on displacement and fluid viscosity)
Minimum Speed 600 rpm (ensures stable operation)
Fluid Medium Mineral oil-based hydraulic fluid (ISO VG 32/46/68 recommended)
Fluid Temperature Range -20 °C to +80 °C (operation); -40 °C to +90 °C (storage)
Viscosity Range 10-1000 mm²/s (operation); 2-1500 mm²/s (start-up)
Rexroth PV7 vane oil pump technical diagram and components
Compatible Model Variants
PV7-2X/20-20RA01MA0-10-P85, PV7-1X/06-10RA01MA0-10-P50, PV7-2X/20-25RA01MA0-05-P32, PV7-1X/06-14RA01MA0-07-P50, PV7-2X/20-25RA01MA0-05-P50, PV7-1X/06-14RA01MA0-07-P65, PV7-1X/06-14RA01MA0-07-P70, PV7-2X/20-20RA01MA0-10-P65, PV7-2X/20-20RA01MA0-05-P25, PV7-2X/20-20RA01MA0-05-P50, PV7-1X/06-14RA01MA0-10-A473, PV7-1X/06-10RA01MA0-10-P100, PV7-1X/06-14RA01MA0-10-A492, PV7-2X/20-20RA01MA0-10-C3.1, PV7-2X/20-20RA01MA0-05-A480, PV7-2X/20-20RA01MA0-10-A480, PV7-1X/06-10RA01MA0-10-C3.1, PV7-2X/20-20RA01MA0-10-P100, PV7-2X/20-25RA01MA0-05-P24Q30, PV7-1X/06-10RA01MA0-05-P35Q11, PV7-2X/20-25RA01MA0-05-P30Q25, PV7-1X/06-10RA01MA0-05-P40Q11, PV7-2X/20-25RA01MA0-05-P30Q36, PV7-1X/06-10RA01MA0-05-P50Q15, PV7-2X/20-25RA01MA0-05-P45Q35, PV7-1X/06-10RA01MA0-10-P55Q12, PV7-2X/20-25RA01MA0-05-P45Q36, PV7-1X/06-10RA01MA0-10-P65Q12, PV7-2X/20-25RA01MA0-10-P63Q35, PV7-1X/06-10RA01MA0-10-P70Q12, PV7-1X/06-10RA01MA0-05-P15Q08, PV7-1X/06-14RA01MA0-07-P70Q18, PV7-1X/06-10RA01MA0-05-P25Q09, PV7-1X/06-14RA01MA0-04-P30Q19, PV7-1X/06-10RA01MA0-05-P25Q11, PV7-1X/06-10RA01MA0-10-P100Q10, PV7-1X/06-10RA01MA0-05-P35Q09, PV7-1X/63-71RE07MC3-16, PV7-1X/100-118RE07MD3-16, PV7-1X/63-71RE07MW0-16WG, PV7-1X/10-20RE01MD5-10, PV7-1X/25-30RE01MW0-16WG, PV7-1X/40-45RE37MW5-16WG, PV7-1X/100-118RE07MC5-16WG, PV7-1X/63-94RE07MC7-08WG, PV7-1X/40-45RE37MW6-16WH, PV7-1X/100-118RE07MD6-16, PV7-1X/40-45RE37MC5-16WG, PV7-1X/100-118RE07MC0-16, PV7-1X/63-71RE07MD0-16, PV7-1X/40-45RE37MC0-16-P90, PV7-1X/25-30RE01MC0-16-P100Q38, PV7-1X/100-150RE07MC0-08-A464, PV7-1X/100-118RE07MD0-16, PV7-1X/10-14RE01MN0-16, PV7-1X/40-45RE37MC5-16, PV7-1X/100-118RE07MC5-16, PV7-1X/25-30RE01KC3-16, PV7-1X/10-20RE01MC5-10WG, PV7-1X/25-30RE01MW0-16, PV7-1X/16-20RE01MD3-16, PV7-1X/16-20RE01MC0-16-P110, PV7-1X/40-45RE37KD0-16-C3.1, PV7-1X/63-71RE07MC5-16WH, PV7-1X/16-30RE01KC0-08, PV7-1X/10-14RE01MD5-16, PV7-1X/63-71RE07MC6-16, PV7-1X/16-20RE01KD0-16, PV7-1X/10-14RE01MW0-16, PV7-1X/63-71RE07MC0-16-C3.1, PV7-1X/16-30RE01MW0-08WH, PV7-1X/100-150RE07MC0-08-A446, PV7-1X/25-30RE01MC5-16WG, PV7-1X/10-20RE01MC0-10-A497, PV7-1X/100-150RE07KC0-08, PV7-1X/100-150RE07MD5-08, PV7-1X/25-45RE01MC0-08-P25Q50, PV7-1X/40-71RE37MC5-08, PV7-1X/10-14RE01KD0-16, PV7-1X/16-20RE01MC0-16-P120, PV7-1X/100-150RE07MW0-08WH, PV7-1X/16-20RE01MC5-16WG, PV7-1X/10-20RE01MW0-10WH, PV7-1X/63-94RE07KD0-08, PV7-1X/63-71RE07MW0-16WH, PV7-1X/63-71RE07MC7-16WH, PV7-1X/40-45RE37MC0-16, PV7-1X/63-94RE07MC0-08-P80Q114, PV7-1X/40-45RE37MC5-16WH, PV7-1X/10-14RE01KN0-16, PV7-1X/25-30RE01MC5-16WH, PV7-1X/63-71RE07KC0-16
Technical Configuration FAQ
Q: How do I calibrate the Pressure Feedback Signal Linearization Gain?
A: Set it to 0.1-5 bar/mA to match the output signal range of your pressure sensor for accurate feedback.
Q: What is the purpose of the Flow Feedback Signal Zero Offset Correction?
A: It compensates for sensor drift, ensuring the flow feedback signal reads zero when there is no fluid flow.
Q: What is the recommended Temperature Feedback Sampling Frequency?
A: Set it to 1-10 Hz; higher frequencies are ideal for monitoring rapid temperature changes.
Q: How do I adjust the Displacement Feedback Sensor Calibration Value?
A: Adjust it to ≤±2% of the nominal displacement to calibrate the displacement sensor for accurate feedback.
Q: How does the Efficiency Feedback Signal Smoothing Time Constant work?
A: A longer time constant (10-1000 ms) reduces noise in efficiency feedback data for more stable readings.
Maintenance Management
Comprehensive maintenance protocols and service intervals available upon request.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location Nan'an, Fujian Province, China
Contact Person liyun

Request A Quote

Please check your email address.
Your message must be at least 20 characters.