Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
                                                                                                           
Verified Supplier
Years
Since
Menu

German made Rexroth proportional relief valve DBETX-1X/50G24-8NZ4M DBETX-1X/80G24-8NZ4M DBETX-1X/315G24-8NZ4M

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 2 weeks
Brand: Rexroth
Product Description
Rexroth Proportional Relief Valve

German made Rexroth proportional relief valve models DBETX-1X/50G24-8NZ4M, DBETX-1X/80G24-8NZ4M, and DBETX-1X/315G24-8NZ4M.

Model Comparison
Parameter DBETX-1X/50G24-8NZ4M DBETX-1X/80G24-8NZ4M DBETX-1X/315G24-8NZ4M
Maximum Working Pressure (P Port) 315 bar 315 bar 315 bar
Maximum Working Pressure (T Port) 50 bar 80 bar 315 bar
Pressure Setting Range 0-50 bar 0-80 bar 0-315 bar
Nominal Flow Rate (Qn) 1.0 L/min 1.0 L/min 1.0 L/min
Power Supply 24 V DC (±10%) 24 V DC (±10%) 24 V DC (±10%)
Solenoid Configuration 8NZ4M 8NZ4M 8NZ4M
Maximum Solenoid Current 0.8 A 0.8 A 0.8 A
Power Consumption 8 W max 8 W max 8 W max
Control Signal 0-10 V DC or 4-20 mA 0-10 V DC or 4-20 mA 0-10 V DC or 4-20 mA
Response Time (0-100%) <50 ms <50 ms <50 ms
Pressure Regulation Accuracy ±1% of full scale ±1% of full scale ±1% of full scale
Hysteresis <0.5% <0.5% <0.5%
Repeatability <0.3% <0.3% <0.3%
Rexroth proportional relief valve technical diagram
Related Part Numbers
  • 0811402036 DBETX-1X/50G24-8NZ4M
  • 0811402018 DBETX-1X/80G24-8NZ4M
  • 0811402017 DBETX-1X/180G24-8NZ4M
  • 0811402019 DBETX-1X/250G24-8NZ4M
  • 0811402016 DBETX-1X/315G24-8NZ4M
  • 0811402034 DBETX-1X/50G24-25NZ4M
  • 0811402030 DBETX-1X/80G24-25NZ4M
  • 0811402031 DBETX-1X/180G24-25NZ4M
  • 0811402035 DBETX-1X/250G24-25NZ4M
  • 0811402032 DBETX-1X/315G24-25NZ4M
  • 0811402013 DBETBX-1X/28G24-37Z4M
  • 0811402007 DBETBX-1X/80G24-37Z4M2
  • 0811402003 DBETBX-1X/180G24-37Z4M
  • 0811402001 DBETBX-1X/250G24-37Z4M2
  • 0811402004 DBETBX-1X/315G24-37Z4M
Additional Model Variants
  • DBETX-1X/50G24-8NZ4M
  • DBETX-1X/80G24-8NZ4M
  • DBETX-1X/315G24-8NZ4M
  • DBETX-1X/180G24-8NZ4M
  • DBETX-1X/250G24-8NZ4M
  • DBETX-1X/80G24-25NZ4M
  • DBETX-1X/50G24-25NZ4M
  • DBETX-1X/180G24-25NZ4M
  • DBETX-1X/315G24-25NZ4M
  • DBETX-1X/250G24-25NZ4M
  • DBET-61/50YG24K4M
  • DBET-61/50YG24K4V
  • DBET-61/100YG24K4M
  • DBET-61/100YG24K4V
  • DBET-61/200YG24K4M
  • DBET-61/200YG24K4V
  • DBET-61/315YG24K4M
  • DBET-61/315YG24K4V
  • DBET-61/350YG24K4M
  • DBET-61/350YG24K4V
  • DBETE-6X/420YG24K31A1V
  • DBETE-6X/50G24K31A1V
  • DBETE-6X/50G24K31F1V
  • DBETE-6X/50YG24K31A1V
  • DBETBX-1X/80G24-37Z4M2
  • DBETBX-1X/250G24-37Z4M2
  • DBETBEX-1X/80G24k31A1M
  • DBETBEX-1X/180G24k31A1M
  • DBETBEX-1X/250G24k31A1M
  • DBETBEX-1X/315G24k31A1M
  • DBETBEX-1X/80G24k31F1M
  • DBETBEX-1X/180G24k31F1M
  • DBETBEX-1X/315G24k31F1M
  • DBEP6A06-1X/45AG24K4M
  • DBEP6B06-1X/45AG24K4M
  • DBEP6C06-1X/45AG24K4M
  • DBEBE6X-1X/180G24K31F1M
  • DBEBE6X-1X/80G24K31A1M
  • DBEBE6X-1X/180G24K31A1M
  • DBEBE6X-1X/315G24K31A1M
  • DBETR-1X/30G24K4M
  • DBETR-1X/80G24K4M
  • DBETR-1X/180G24K4M
  • DBETR-1X/230G24K4M
  • DBETR-1X/315G24K4M
  • DBETR-1X/350G24K4M
  • DBET-52/50G24K4M
  • DBETE-52/100G24K31F1M
  • DBETE-52/350G24K31F1M
  • DBETE-52/350G24K31A1V
  • DBETE-52/350G24K31A1M
  • DBETE-52/315G24K31F1V
Frequently Asked Questions
What is the main difference between the 50G24, 80G24, and 315G24 models?

The primary difference is the pressure setting range. The DBETX-1X/50G24-8NZ4M offers 0-50 bar, the /80G24-8NZ4M provides 0-80 bar, and the /315G24-8NZ4M covers 0-315 bar. All three models share identical mechanical dimensions, electrical interfaces (8NZ4M solenoid), and mounting configurations, but are calibrated for different pressure ranges to suit various system requirements. The choice depends on your maximum operating pressure needs.

What does the 8NZ4M solenoid configuration mean, and how does it differ from other configurations?

The 8NZ4M configuration indicates a standard current solenoid with 0.8A maximum current. This differs from higher-current configurations like 25NZ4M (2.5A) or 37Z4M (3.7A) in several ways: lower power consumption (8W vs 40W), slower response time (<50 ms vs <30 ms), and reduced electromagnetic force. The 8NZ4M is more cost-effective but may not be suitable for applications requiring rapid dynamic response or handling high-viscosity fluids.

Do these models include position feedback like the DBETBX series?

No, the DBETX-1X series with 8NZ4M configuration does not include integrated position feedback. These are open-loop control valves that rely on the external amplifier to drive the solenoid without spool position monitoring. If you require closed-loop control, position feedback, or diagnostic capabilities, you would need to consider the DBETBX series or other models with position sensor options.

Can I use the 315G24 model with 8NZ4M solenoid for high-pressure applications?

Yes, but with important considerations. While the valve is rated for 315 bar pressure, the 8NZ4M solenoid has lower electromagnetic force compared to higher-current options. This means response times may be slower, and performance in high-viscosity fluids or demanding dynamic applications could be affected. For critical high-pressure applications, it's recommended to evaluate whether the 8NZ4M configuration meets your dynamic performance requirements or if a higher-current solenoid would be more appropriate.

What type of external amplifier is required for these valves?

These valves require a proportional amplifier that can provide 24V DC power supply and process the control signal (0-10V or 4-20mA). The amplifier must be compatible with the 8NZ4M solenoid configuration, meaning it should be capable of delivering up to 0.8A current. Ensure the amplifier's current output capability matches the solenoid requirements. The amplifier should also provide appropriate signal conditioning and protection features.

Are these valves suitable for water-glycol or other non-mineral oil fluids?

The standard models come with NBR seals, which are primarily compatible with mineral oils (HL, HLP). For water-glycol, HFC fluids, or other non-mineral oil fluids, special seal materials (such as FKM or EPDM) may be required. Before using with alternative fluids, consult the manufacturer's fluid compatibility guide or contact technical support to confirm seal material suitability. Using incompatible fluids may cause seal degradation and premature failure.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location Nan'an, Fujian Province, China
Contact Person liyun

Request A Quote

Please check your email address.
Your message must be at least 20 characters.