Rexroth 4WE10E5X/HG24N9K4/M Directional Valve - Parameter Table
|
Parameter |
Value / Description |
|---|---|
|
Valve Type |
Solenoid-operated directional control valve |
|
Model |
4WE 10 E5X/HG24N9K4/M |
|
Design |
Wet-pin solenoid; Subplate mounting |
|
Connection Size (P/A/B/T) |
G 1/4" |
|
Nominal Size |
10 mm |
|
Maximum Operating Pressure |
315 bar |
|
Maximum Flow Rate |
60 l/min |
|
Number of Positions/Ways |
4-way, 3-position |
|
Spool Type (E5X) |
Pressure port P to tank T, work ports A & B connected to pressure P in center position ("Open P to A&B center" or "Regenerative center") |
|
Control Method |
Single solenoid, with spring return to center |
|
Solenoid Specification (HG24N9K4) |
24V DC; with manual override; plug connector (DIN 43650 Form A) |
|
Operating Voltage |
24V DC |
|
Power Consumption |
Typically ~22W (Confirm with official datasheet) |
|
Protection Class (Coil) |
IP65 standard |
|
Duty Cycle |
100% |
|
Mounting |
According to ISO 4401-05 (CETOP 5) |
|
Weight (approx.) |
~3.0 kg (with coil) |
|
Housing Material |
Aluminum alloy |
|
Sealing Material |
Nitrile rubber (NBR) standard; FKM optional |
|
Fluid Temperature Range |
-20 °C to +80 °C (with NBR seals) |
|
Recommended Viscosity Range |
10 to 400 mm²/s |
|
Fluid Compatibility |
Mineral oils (HL, HLP per ISO 6743-4) |
|
Filtration Requirement |
Cleanliness class 20/18/15 per ISO 4406 (recommended) |
| R901344560 4WE10D5X/EG220N9K4/V |
| R901424561 4WE10D5X/EG220N9K4/VSO924 |
| R901372424 4WE10D5X/EG24K4/B10M |
| R901429729 4WE10D5X/EG24K4/B20M |
| R901321288 4WE10D5X/EG24K4/M |
| R901347407 4WE10D5X/EG24K4/V |
| R901376294 4WE10D5X/EG24N5K4/M |
| R901376297 4WE10D5X/EG24N6DK6L/M |
| R901385372 4WE10D5X/EG24N6K4/M |
| R901376291 4WE10D5X/EG24N8DK6L/M |
| R901455531 4WE10D5X/EG24N8DL/M |
| R901349805 4WE10D5X/EG24N8K4/M |
| R901384705 4WE10D5X/EG24N8K4K/T12M |
| R901430319 4WE10D5X/EG24N9DK25L/M |
| R901362273 4WE10D5X/EG24N9DK6L/M |
| R901388694 4WE10D5X/EG24N9DK6L/V |
| R901340195 4WE10D5X/EG24N9DL/M |
| R901393179 4WE10D5X/EG24N9DL/M=CSA |
| R901361250 4WE10D5X/EG24N9K4/B08M |
| R901368964 4WE10D5X/EG24N9K4/B10M |
| R901340453 4WE10D5X/EG24N9K4/B12M |
| R901333452 4WE10D5X/EG24N9K4/B12MH |
| R901351945 4WE10D5X/EG24N9K4/B12V |
| R901350503 4WE10D5X/EG24N9K4/B20M |
| R901350031 4WE10D5X/EG24N9K4/B30M |
| R901278760 4WE10D5X/EG24N9K4/M |
| R901388847 4WE10D5X/EG24N9K4/M=AN |
| R901410302 4WE10D5X/EG24N9K4/M=CSA |
| R901317861 4WE10D5X/EG24N9K4/M=TE |
| R901321520 4WE10D5X/EG24N9K4/MH |
| R901349661 4WE10D5X/EG24N9K4/T06M |
| R901278783 4WE10D5X/EG24N9K4/V |
| R901316038 4WE10D5X/EG24N9K4/V=KM |
| R901371306 4WE10D5X/EG24N9K4/X40M |
| R901339384 4WE10D5X/EG24N9K4K/M |
| R901349576 4WE10D5X/EG24N9K72L/M |
| R901350504 4WE10D5X/EG24N9K72L/M=AN |
| R901353846 4WE10D5X/EG26N9C4Z/M |
| R901423918 4WE10D5X/EG26N9K4K/M |
| R901403956 4WE10D5X/EG48N9K4/M |
| R901393598 4WE10D5X/EG96N9DL/B04M |
| R901347114 4WE10D5X/EG96N9K4/B10M |
| R901402680 4WE10D5X/EG96N9K4/B12M |
| R901347132 4WE10D5X/EG96N9K4/B20M |
Rexroth 4WE10E5X/HG24N9K4/M Directional Valve - FAQ
Q1: What is the unique feature of the "E5X" spool?
A: The "E5X" spool has a unique center position function. In the neutral (spring-centered) state, it connects the pressure port (P) to both work ports (A & B) and also to the tank port (T). This creates a specific pressure condition on both sides of an actuator.
Q2: What is this center position used for?
A: This "open center to A, B, and T" configuration is less common. It is typically used in specialized applications, such as holding a double-acting cylinder under equal pressure from both sides in the neutral position, or in certain closed-center circuits that require a specific pre-charge or unloading path. It is not a standard float or closed-center function.
Q3: How is the valve operated?
A: It is controlled by a single 24V DC solenoid ("HG24N9K4" coil). Energizing the solenoid shifts the spool to one working position. De-energizing it allows internal springs to return the spool to the unique center position described above. A manual override is provided.
Q4: What are the pressure and flow ratings?
A: Maximum operating pressure: 315 bar. Maximum recommended flow rate: 60 liters per minute.
Q5: What are the electrical details?
A: The solenoid operates on 24V DC, with a protection class of IP65. Please refer to the official data sheet for exact power and current specifications.
Q6: How is the valve installed?
A: It mounts on a standard ISO 4401-05 (CETOP 5) subplate. The hydraulic ports are G 1/4". Electrical connection is via a standard plug connector.
Q7: What are the fluid requirements?
A: Use standard mineral-based hydraulic oils (HL, HLP). High fluid cleanliness (ISO 4406 20/18/15 recommended) with proper filtration is essential.
Q8: Where can I find the complete technical information?
A: For the complete datasheet, performance curves, and the exact hydraulic symbol for this specific spool type, please consult the official technical documentation for order code R901390857.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.