R900731881 4WRKE25W8-350L-3X/6EG24ETK31/A1D3M German Rexroth proportional electromagnetic directional control valve

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 2 weeks
Brand: Rexroth
Product Description

Parameter

Specification

Order Number

R900731881

Model

4WRKE25W8-350L-3X/6EG24ETK31/A1D3M

Type

Pilot-operated, 2-stage proportional directional valve

Function

4/3-way (3 positions, 4 ports), spring-centered

Spool Type

W8 (Overlap spool, with electrical position feedback)

Nominal Size

NG25​ (CETOP 8)

Max. Operating Pressure

P, A, B: 350 bar

Rated Flow

350 L/min​ (at Δp = 10 bar per control land)

Max. Flow

Approx. 870 L/min

Electronics

Integrated On-Board Electronics (OBE)

Supply Voltage

24V DC​ (18...35 VDC)

Control Signal

±10 V DC​ (Analog voltage input, /A1​ suffix)

Feedback

Electrical spool position feedback (LVDT, /ET)

Pilot Oil Supply

External (X)

Pilot Oil Return

External (Y)

Manual Override

No

Pressure Reducing Valve

Yes (D3, ZDR 6 DP0-4X/40YM)

Seal Material

NBR (M)

Electrical Connector

7-pin plug (DIN EN 175201-804, K31)

Mounting Interface

ISO 4401-08-07-0-94 (CETOP 8 subplate)

Suitable Media

Mineral oils (HL, HLP), HETG, HEES, HEPG, HFDU, HFDR

Media Temperature

-20°C to +80°C​ (optimal 40–50°C)

Viscosity Range

20 to 380 mm²/s

Weight

Approx. 17.9 kg

4WRZE25E1-325-72/6EG24N9EK31/A1V
4WRZE25E1-325-72/6EG24N9EK31/F1D3M
4WRZE25E1-325-72/6EG24N9ETK31/A1D3M
4WRZE25E1-325-72/6EG24N9ETK31/A1M
4WRZE25E1-325-72/6EG24N9K31/A1D3M
4WRZE25E1-325-72/6EG24N9K31/F1V
4WRZE25E220-72/6EG24ETK31/A1D3M
4WRZE25E220-72/6EG24K31/A1M
4WRZE25E220-72/6EG24N9EK31/A1D3V
4WRZE25E220-72/6EG24N9EK31/A1M
4WRZE25E220-72/6EG24N9ETK31/F1D3M
4WRZE25E220-72/6EG24N9K31/A1D3M
4WRZE25E325-72/6EG24ETK31/A1D3M
4WRZE25E325-72/6EG24K31/A1D3M
4WRZE25E325-72/6EG24N9EK31/A1D3V
4WRZE25E325-72/6EG24N9ETK31/A1D3V
4WRZE25E325-72/6EG24N9ETK31/A1V
4WRZE25E325-72/6EG24N9K31/A1D3V
4WRZE25E3-325-72/6EG24EK31/A1D3M
4WRZE25EA325-72/6EG24ETK31/A1M
4WRZE25EB220-72/6EG24K31/A1M
4WRZE25W6-220-72/6EG24EK31/A1D3M
4WRZE25W6-220-72/6EG24EK31/F1D3M
4WRZE25W6-220-72/6EG24ETK31/A1D3M
4WRZE25W6-220-72/6EG24K31/A1D3M
4WRZE25W6-220-72/6EG24K31/F1D3M
4WRZE25W6-220-72/6EG24K31/F1V
4WRZE25W6-220-72/6EG24N9EK31/A1D3M
4WRZE25W6-220-72/6EG24N9EK31/A1D3V
4WRZE25W6-220-72/6EG24N9EK31/A1M
4WRZE25W6-220-72/6EG24N9EK31/F1D3M
4WRZE25W6-220-72/6EG24N9ETK31/A1D3M
4WRZE25W6-220-72/6EG24N9ETK31/F1D3M
4WRZE25W6-220-72/6EG24N9K31/A1M
4WRZE25W6-220-72/6EG24N9K31/F1D3M
4WRZE25W6-220-72/6EG24N9K31/F1D3V
4WRZE25W6-220-72/6EG24N9K31/F1V
4WRZE25W6-325-72/6EG24EK31/F1D3M
4WRZE25W6-325-72/6EG24ETK31/A1D3M
4WRZE25W6-325-72/6EG24ETK31/F1D3V
4WRZE25W6-325-72/6EG24ETK31/F1M
4WRZE25W6-325-72/6EG24K31/A1D3M
4WRZE25W6-325-72/6EG24K31/A1M
4WRZE25W6-325-72/6EG24K31/F1D3M
4WRZE25W6-325-72/6EG24N9EK31/A1D3M
4WRZE25W6-325-72/6EG24N9EK31/A1M
4WRZE25W6-325-72/6EG24N9EK31/A1V
4WRZE25W6-325-72/6EG24N9EK31/F1D3M
4WRZE25W6-325-72/6EG24N9EK31/F1M
4WRZE25W6-325-72/6EG24N9ETK31/A1D3M
4WRZE25W6-325-72/6EG24N9ETK31/A1M
4WRZE25W6-325-72/6EG24N9ETK31/F1D3M
4WRZE25W6-325-72/6EG24N9K31/A1M
4WRZE25W6-325-72/6EG24N9K31/A1V
4WRZE25W6-325-72/6EG24N9K31/F1D3M
4WRZE25W6-325-72/6EG24N9K31/F1D3V
4WRZE25W6-325-72/6EG24N9K31/F1M
4WRZE25W6-325-72/6EG24N9K31/F1V
4WRZE25W6-325-72/6EG24N9TK31/A1D3M
4WRZE25W6-325-72/6EG24N9TK31/F1D3V
4WRZE25W8-220-72/6EG24EK31/A1D3M
4WRZE25W8-220-72/6EG24EK31/F1D3M
4WRZE25W8-220-72/6EG24ETK31/A1D3M

FAQ:

  1. Spool Type (W8)

    The W8 spool​ is an overlap spool​ (positive overlap). This design minimizes internal leakage when the valve is in the center position but requires a higher deadband control signal to initiate movement. It is suitable for applications where holding position and minimal leakage are critical.

  2. Control Signal (/A1)

    The /A1​ suffix (±10 V voltage input) is ideal for high-precision control systems​ (e.g., servo controllers, motion controllers) where fine resolution and fast signal response are required.

  3. Pilot Oil Configuration (/6EG24ETK31)

    This valve uses external pilot oil supply (X port) and external pilot oil return (Y port). You must provide clean, filtered pilot oil to the X port (typically 25–315 bar) and ensure the Y port drains directly to the tank with minimal backpressure (max 10 bar).

  4. Integrated Pressure Reducing Valve (/D3)

    The /D3​ option includes an integrated ZDR 6​ pressure reducing valve. It ensures the pilot stage receives a stable, reduced pressure (typically around 40 bar), protecting the sensitive pilot valve from high and fluctuating main system pressures.

  5. Critical Installation Notes

    • Drain Line:​ The external pilot drain (Y port) must be connected directly to the tank with a dedicated line. Backpressure on Y must be < 10 bar.

    • Cleanliness:​ Maintain high oil cleanliness (recommended NAS 1638 Class 8 or ISO 4406 20/18/15 for the main stage).

    • Pilot Supply:​ Provide clean, regulated pilot pressure to the X port.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location Nan'an, Fujian Province, China
Contact Person liyun

Request A Quote

Please check your email address.
Your message must be at least 20 characters.