R901304402 DBE6-2X/315YG24K4/M Proportional overflow valve from Rexroth Germany
|
Parameter |
Specification |
|---|---|
|
Order Number |
R901304402 |
|
Model |
DBE6-2X/315YG24K4/M |
|
Type |
Pilot-operated proportional pressure relief valve (main stage + pilot poppet) |
|
Function |
2-port, normally closed (P → T pressure limiting) |
|
Nominal Size |
NG6 (CETOP 3, Size 6) |
|
Max. Operating Pressure |
Port P: 350 bar |
|
Adjustable Pressure Range |
0 – 315 bar (electrically proportional) |
|
Rated Flow |
30 L/min (maximum controlled flow) |
|
Valve Design |
Pilot-operated (internal pilot oil), without integrated electronics (OBE) |
|
Supply Voltage |
24V DC (G24) |
|
Control Signal |
External amplifier required (e.g., VT-5000 series, input ±10 V or 0–20 mA) |
|
Solenoid Current |
Approx. 1.76 A (standard coil, not low-power) |
|
Electrical Connector |
3-pole plug socket (K4) per EN 175301-803 (2 poles + PE) |
|
Mounting Interface |
ISO 4401-03-02-0-05 (NG6 subplate) |
|
Seal Material |
NBR (Nitrile) (M) |
|
Suitable Media |
Mineral oils (HL, HLP), HFD fluids |
|
Media Temperature |
-20°C to +80°C |
|
Viscosity Range |
15 – 380 mm²/s (recommended 20–100 mm²/s) |
|
Ambient Temperature |
-20°C to +70°C |
|
Cleanliness Requirement |
ISO 4406 20/18/15 or better |
|
Control Performance |
Hysteresis < 3 %, Repeat accuracy < ±2 % |
|
Weight |
Approx. 2.0 – 2.5 kg |
| DBETBEX-1X/180G24k31F1M |
| DBETBEX-1X/315G24k31F1M |
| DBEP6A06-1X/45AG24K4M |
| DBEP6B06-1X/45AG24K4M |
| DBEP6C06-1X/45AG24K4M |
| DBEBE6X-1X/180G24K31F1M |
| DBEBE6X-1X/80G24K31A1M |
| DBEBE6X-1X/180G24K31A1M |
| DBEBE6X-1X/315G24K31A1M |
| DBETR-1X/30G24K4M |
| DBETR-1X/80G24K4M |
| DBETR-1X/180G24K4M |
| DBETR-1X/230G24K4M |
| DBETR-1X/315G24K4M |
| DBETR-1X/350G24K4M |
| DBET-52/50G24K4M |
| DBETE-52/100G24K31F1M |
| DBETE-52/350G24K31F1M |
| DBETE-52/350G24K31A1V |
| DBETE-52/350G24K31A1M |
| DBETE-52/315G24K31F1V |
| DBETE-52/315G24K31F1M |
| DBETE-52/315G24K31A1V |
| DBETE-52/315G24K31A1M |
| DBETE-52/200G24K31F1V |
| DBETE-52/200G24K31F1M |
| DBETE-52/200G24K31A1V |
| DBETE-52/200G24K31A1M |
| DBETE-52/100G24K31F1V |
| DBETE-52/100G24K31A1V |
| DBET-52/50G24K4V |
| DBETE-52/100G24K31A1M |
| DBETE-52/50G24K31F1V |
| DBETE-52/50G24K31F1M |
| DBETE-52/50G24K31A1V |
| DBETE-52/50G24K31A1M |
| DBET-52/350G24K4V |
| DBET-52/350G24K4M |
| DBET-52/315G24K4V |
| DBET-52/315G24K4M |
| DBET-52/200G24K4V |
| DBET-52/200G24K4M |
| DBET-52/100G24K4V |
| DBET-52/100G24K4M |
| DBETE-52/350G24K31F1V |
| DBETE-5X/50G24K31A1M |
| DBETE-5X/100G24K31A1V |
| DBETE-5X/350G24K31F1M |
| DBETE-5X/350G24K31A1V |
| DBETE-5X/350G24K31A1M |
FAQ:
-
Pilot-Operated Design (DBE6 vs. DBET)
This valve uses a two-stage design: a small direct-operated pilot stage controls a larger main spool stage. This allows it to handle high flows (30 L/min) with low hysteresis, making it suitable for main system relief applications. This is a key difference from the DBET series, which are only for pilot flow or very small circuits.
-
External Pilot Drain (Y)
The "Y" in the model code indicates external pilot drain. Port Y (pilot control oil drain) must be connected directly to tank with minimal backpressure. High backpressure at port Y will directly reduce the effective cracking pressure (P_effective = P_set - P_Y). This is critical for accurate pressure control.
-
Pressure Rating (315 bar)
The "315" denotes the maximum electrically adjustable pressure rating of 315 bar. The valve's mechanical pressure limit is higher (350 bar), providing a safety margin. The working pressure at port P must not exceed 350 bar.
-
External Electronics Required (/K4)
The suffix /K4 indicates a 3-pole plug socket for connection to an external control amplifier (e.g., Rexroth VT-5000 series). The valve itself has no on-board electronics (OBE), so you must provide an external amplifier that delivers the controlled current (up to ~1.76 A) to the solenoid.
-
Critical Installation Notes
-
External Amplifier: Mandatory. The valve cannot function without an external amplifier to drive the solenoid.
-
Subplate Mounting: Requires an NG6 subplate (ISO 4401-03-02-0-05). The valve itself has no integrated ports.
-
Return Line Pressure: Port T and Port Y must be kept at low pressure (ideally tank pressure). High backpressure will reduce the effective setting pressure.
-
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.