R900928873 DRE6-1X/21OMG24K4M German Rexroth proportional pressure reducing valve
|
Parameter |
Specification |
|---|---|
|
Order Number |
R900928873 |
|
Model |
DRE6-1X/210MG24K4M |
|
Type |
Pilot-operated proportional pressure reducing valve (3-way spool type) |
|
Function |
Reduce inlet pressure (P) to a controlled secondary pressure (A) |
|
Nominal Size |
NG6 (CETOP 3, Size 6) |
|
Max. Operating Pressure |
Port P (Inlet): 315 bar |
|
Adjustable Pressure Range |
0 – 210 bar (electrically proportional) |
|
Max. Flow Capacity |
30 L/min |
|
Valve Design |
Pilot-operated spool valve, requires external amplifier |
|
Supply Voltage |
24V DC (G24) |
|
Control Signal |
Requires external amplifier (e.g., VT-5000) for 0–10 V or 4–20 mA input |
|
Electrical Connector |
3-pin (2+PE) device connector (K4) per EN 175301-803 |
|
Mounting Interface |
ISO 4401-03-02-0-05 (NG6 subplate) |
|
Seal Material |
NBR (M) |
|
Suitable Media |
Mineral oils (HL, HLP), HVLP, HFC, HLPD, HVLPD |
|
Media Temperature |
-20°C to +80°C |
|
Viscosity Range |
15 – 380 mm²/s (recommended 30–46 mm²/s) |
|
Ambient Temperature |
-20°C to +70°C |
|
Cleanliness Requirement |
ISO 4406 20/18/15 or better |
|
Control Performance |
Hysteresis ≤ ±2.5 %, Linearity ±3.5 %, Repeat accuracy < ±2 % |
|
Weight |
Approx. 1.76 kg |
| R900967050 ZDRE6VP1-1X/100MG24K4M |
| R900958957 ZDRE6VP1-1X/100MG24K4V |
| R901252622 ZDRE6VP1-1X/100MG24N9K4M |
| R901252623 ZDRE6VP1-1X/100MG24N9K4V |
| R900915958 ZDRE6VP1-1X/100MG24NK4M |
| R900933523 ZDRE6VP1-1X/100MG24NK4V |
| R900536114 ZDRE6VP1-1X/100MG24NZ4M |
| R900537078 ZDRE6VP1-1X/100MG24Z4M |
| R900914590 ZDRE6VP1-1X/100MG24Z4V |
| R900966203 ZDRE6VP1-1X/210MG24K4M |
| R900719800 ZDRE6VP1-1X/210MG24K4V |
| R901252624 ZDRE6VP1-1X/210MG24N9K4M |
| R901252625 ZDRE6VP1-1X/210MG24N9K4V |
| R900915959 ZDRE6VP1-1X/210MG24NK4M |
| R900915960 ZDRE6VP1-1X/210MG24NK4V |
| R900536527 ZDRE6VP1-1X/210MG24NZ4M |
| R900551016 ZDRE6VP1-1X/210MG24NZ4V |
| R900569277 ZDRE6VP1-1X/210MG24Z4M |
| R900902595 ZDRE6VP1-1X/210MG24Z4V |
| R901442570 ZDRE6VP1-1X/315MG24N9K4M |
| R900617992 ZDRE6VP1-1X/50MG24K4M |
| R901106374 ZDRE6VP1-1X/50MG24K4V |
| R901252626 ZDRE6VP1-1X/50MG24N9K4M |
| R901252627 ZDRE6VP1-1X/50MG24N9K4V |
| R900915961 ZDRE6VP1-1X/50MG24NK4M |
| R900946738 ZDRE6VP1-1X/50MG24NK4V |
| R900550552 ZDRE6VP1-1X/50MG24NZ4M |
| R900901823 ZDRE6VP1-1X/50MG24Z4M |
| R900930942 ZDRE6VP2-1X/100MG24K4M |
| R900950897 ZDRE6VP2-1X/100MG24K4V |
| R901252628 ZDRE6VP2-1X/100MG24N9K4M |
| R901252629 ZDRE6VP2-1X/100MG24N9K4V |
| R900574926 ZDRE6VP2-1X/100MG24NK4M |
FAQ:
-
High Reduced Pressure Rating (210 bar)
The "210" denotes the maximum electrically adjustable reduced pressure at port A. The inlet at port P can be up to 315 bar, but the valve will regulate port A to a maximum of 210 bar. This is the high-pressure variant of the DRE6 series (compared to the 100 bar and 50 bar versions).
-
Requires External Amplifier
Unlike the DREE series with integrated electronics (OBE), the DRE6 series requires an external proportional amplifier (e.g., Rexroth VT-5000 series). The valve's coil is driven by the amplifier, which accepts the command signal (0–10 V or 4–20 mA). The "M" in the code indicates a standard proportional solenoid coil.
-
3-Way Function (P, A, T)
This valve has three working ports: P (inlet), A (reduced pressure outlet), and T (tank). It continuously compares the A-port pressure with the electrical setpoint. If A-port pressure is too high, it opens a path to T to bleed off excess pressure and maintain the set value.
-
Pilot-Operated Design
This is a pilot-operated valve, not a direct-operated poppet. It uses a small pilot flow (approx. 0.65 L/min) for control, which allows for higher main flow capacity (30 L/min) and faster response compared to direct-operated valves.
-
Critical Installation Notes
-
External Amplifier Needed: You must use an external amplifier card to drive the valve. The K4 connector on the valve only carries coil power from the amplifier.
-
Tank Line Backpressure: Port T must be connected directly to tank with minimal backpressure. High backpressure at T will be added to the A-port pressure, causing inaccurate regulation.
-
Pilot Flow: Ensure your system can supply the small pilot flow required for the valve's internal operation.
-