R901278310 DREE20-6X/315YMG24K31A1M German made Rexroth proportional relief valve
|
Parameter |
Specification |
|---|---|
|
Order Number |
R901278310 |
|
Model |
DREE20-6X/315YMG24K31A1M |
|
Type |
Pilot-operated proportional pressure reducing valve (2-way, B→A) |
|
Function |
Reduces inlet pressure (B) to controlled secondary pressure (A); excess flow internally drained |
|
Nominal Size |
NG20 (CETOP 7, Size 20) |
|
Max. Operating Pressure |
Port A & B: 315 bar |
|
Adjustable Pressure Range |
~2 – 315 bar (Electrically proportional, 0–10V) |
|
Max. Flow Capacity |
300 L/min |
|
Pilot Flow Consumption |
Approx. 0.8 – 1.2 L/min (Internal pilot supply) |
|
Valve Design |
Pilot-operated spool valve, with integrated electronics (OBE) |
|
Supply Voltage |
24V DC (G24) |
|
Control Signal |
0 – +10 V (A1) |
|
Electrical Connector |
6-pin + PE (K31) per DIN EN 175201-804 |
|
Special Features |
Integrated electronics (OBE), Mechanical max. pressure limiter (M), External pilot drain (Y), No check valve (M) |
|
Mounting Interface |
ISO 5781-AG-10-2-A (NG20 subplate) |
|
Seal Material |
NBR (M) |
|
Suitable Media |
Mineral oils (HL, HLP), HLP-D, HVLP, HFC fluids |
|
Media Temperature |
-20°C to +80°C |
|
Viscosity Range |
15 – 380 mm²/s (recommended 30–46 mm²/s) |
|
Ambient Temperature |
-20°C to +50°C (electronics) |
|
Cleanliness Requirement |
ISO 4406 20/18/15 or better |
|
Control Performance |
Hysteresis ≤ ±3.5 %, Repeat accuracy < ±2 % |
|
Weight |
Approx. 6.1 – 6.2 kg |
| R901336443 ZDREE6VP3-1X/50MG24K24A1M |
| R901332583 ZDREE6VP3-1X/50MG24K24F1M |
| R901346257 ZDREE6VP3-1X/50MG24K24F1V |
| R901333120 ZDREE6VP4-1X/100MG24K24A1M |
| R901342612 ZDREE6VP4-1X/100MG24K24F1M |
| R901419420 ZDREE6VP4-1X/100MG24K24F1V |
| R901344934 ZDREE6VP4-1X/210MG24K24A1M |
| R901434069 ZDREE6VP4-1X/210MG24K24F1M |
| R901343769 ZDREE6VP4-1X/210MG24K24F1V |
| R901358800 ZDREE6VP4-1X/210MG24N9K24A1M |
| R901366630 ZDREE6VP4-1X/210MG24N9K24F1M |
| R901374071 ZDREE6VP4-1X/210MG24N9K24F1V |
| R901404475 ZDREE6VP4-1X/315MG24K24F1M |
| R901437499 ZDREE6VP4-1X/315MG24N9K24F1M |
| R901410698 ZDREE6VP4-1X/50MG24K24A1M |
| 力士乐REXROTH先导式比例减压阀ZDRE 10, ZDREE 10 |
| R901219741 ZDRE10VP2-2X/100LMG24K4M |
| R901241817 ZDRE10VP2-2X/100LMG24K4V |
| R901215393 ZDRE10VP2-2X/100XLMG24K4M |
| R901241816 ZDRE10VP2-2X/100XLMG24K4V |
| R901283725 ZDRE10VP2-2X/100XYMG24K4M |
| R901308768 ZDRE10VP2-2X/100XYMG24K4V |
| R901160006 ZDRE10VP2-2X/100YMG24K4M |
| R901273232 ZDRE10VP2-2X/200LMG24K4M |
| R901227551 ZDRE10VP2-2X/200XLMG24K4M |
| R901220758 ZDRE10VP2-2X/200XLMG24K4V |
| R901247462 ZDRE10VP2-2X/200XYMG24K4M |
| R901160004 ZDRE10VP2-2X/200YMG24K4M |
| R901262400 ZDRE10VP2-2X/200YMG24K4V |
| R901254861 ZDRE10VP2-2X/315LMG24K4M |
| R901251520 ZDRE10VP2-2X/315XLMG24K4M |
| R901213578 ZDRE10VP2-2X/315XLMG24K4V |
| R901324287 ZDRE10VP2-2X/315XYMG24K4M |
| R901160008 ZDRE10VP2-2X/315YMG24K4M |
| R901426460 ZDRE10VP2-2X/315YMG24K4V |
| R901251082 ZDRE10VP2-2X/50XLMG24K4M |
| R901337570 ZDRE10VP2-2X/50XLMG24K4V |
| R901291142 ZDRE10VP2-2X/50XYMG24K4M |
| R901160011 ZDRE10VP2-2X/50YMG24K4M |
| R901236347 ZDRE10VP2-2X=315XLMG24K4M |
| 0811402165 ZDRE10VP2X-1X/180LG24-25Z4M-8 |
| 0811402164 ZDRE10VP2X-1X/180LG24-25Z4M-9 |
| 0811402173 ZDRE10VP2X-1X/250YMG24-8Z4M-6 |
| R901328060 ZDREE10VP2-2X/100LMG24K31F1M |
| R901336017 ZDREE10VP2-2X/100LMG24K31F1V |
| R901198304 ZDREE10VP2-2X/100XLMG24K31A1M |
| R901213581 ZDREE10VP2-2X/100XLMG24K31A1V |
| R901219275 ZDREE10VP2-2X/100XLMG24K31F1M |
| R901314479 ZDREE10VP2-2X/100XLMG24K31F1V |
| R901277502 ZDREE10VP2-2X/100XYMG24K31A1M |
| R901196776 ZDREE10VP2-2X/100YMG24K31A1M |
| R901315639 ZDREE10VP2-2X/100YMG24K31A1V |
| R901274751 ZDREE10VP2-2X/100YMG24K31F1M |
| R901316208 ZDREE10VP2-2X/100YMG24K31F1V |
FAQ:
-
Integrated Electronics (OBE)
The "E" in DREE confirms On-Board Electronics (OBE). This means the valve contains its own amplifier. You supply 24V DC power and a 0–10 V command signal directly to the valve's K31 connector. This simplifies wiring and eliminates the need for an external VT-VSPA amplifier.
-
Mechanical Maximum Pressure Limiter (M)
The "M" immediately after DREE20 indicates the valve includes a mechanical safety relief valve as a maximum pressure limiter. This is a safety feature that hydraulically limits the maximum pressure at port A to approximately 350 bar, protecting the system in case of an electrical control fault.
-
High Pressure & Flow Rating (315 bar / 300 L/min)
The "315" denotes the maximum electrically adjustable reduced pressure at port A. This is the highest pressure variant in the DREE20 series, capable of handling flows up to 300 L/min, making it suitable for high-power industrial systems.
-
External Pilot Drain (Y) & No Check Valve
-
"Y": The pilot control oil must be drained externally via port Y. This port must be connected directly to the tank with minimal backpressure. High backpressure at Y will cause inaccurate pressure regulation.
-
"M" at the end: The suffix "M" indicates no check valve is included between ports A and B. This means flow from port A back to port B is blocked by the spool design. If your application requires free reverse flow (A→B), you would need a variant without the final "M" code.
-
-
Critical Installation Notes
-
Port Y Drain: Must be piped separately to tank with a line diameter ≥ 5 mm and length < 2.5 m to avoid backpressure issues.
-
Zero Signal Pressure: With a 0 V command signal, the valve maintains a minimum pressure of approximately 2 bar at port A.
-
Subplate: Requires an NG20 subplate according to ISO 5781-AG-10-2-A (e.g., Rexroth RE 45102 series).
-
Correction: Your description mentioned "proportional relief valve", but this model is specifically a proportional pressure reducing valve. It controls the downstream (A-port) pressure, not the system relief pressure.
Get in Touch