R900956101 3DREP6C-2X=25EG24N9K4/M=00 German Rexroth proportional pressure reducing valve
|
Parameter |
Value / Description |
|---|---|
|
Order Code |
R900956101 |
|
Model |
3DREP6C-2X/25EG24N9K4/M=00 |
|
Type |
Direct-acting proportional pressure reducing valve (3-way) |
|
Size |
NG6 |
|
Max. Operating Pressure |
100 bar (P, A, B) |
|
Max. Flow Rate |
15 L/min |
|
Adjustable Pressure Range |
0 – 25 bar (proportional to signal) |
|
Mounting |
Subplate (ISO 4401) |
|
Control Type |
Proportional solenoid with external electronics |
|
Supply Voltage |
24 V DC |
|
Command Signal |
±9 V or ±10 V (external amplifier required) |
|
Electrical Connector |
3-pole (2 + PE) |
|
Seals |
NBR (standard for mineral oil) |
|
Weight |
Approx. 2.0 kg |
| R900931050 3DREPE6B-2X/25EG24N9K31/A1V |
| R900925484 3DREPE6C-2X/25EG24N9K31/A1V |
| R900929865 3DREPE6B-2X/45EG24N9K31/A1V=LB |
| R900954428 3DREPE6C-2X/45EG24K31/A1M |
| R900954428 3DREPE6C-2X/45EG24K31/A1M |
| R900970698 3DREPE6C-2X/45EG24N9K31/F1V |
| R900954422 3DREPE6A-2X/16EG24K31/A1M |
| R900954423 3DREPE6A-2X/25EG24K31/A1M |
| R900975912 3DREPE6A-2X/25EG24N9K31/F1V |
| R900700593 3DREPE6C-2X/16EG24N9K31/A1V |
| R900955887 3DREP6C-21=25EG24N9K4/M |
| R900955803 3DREP6A-2X/25EG24N9K4/M |
| R900955796 3DREP6C-2X/45EG24N9K4/M |
| R900954422 3DREPE6A-2X/16EG24K31/A1M |
| R900954423 3DREPE6A-2X/25EG24K31/A1M |
| R900954424 3DREPE6A-2X/45EG24K31/A1M |
| R900954425 3DREPE6C-2X/16EG24K31/A1M |
| R900956101 3DREP6C-20=25EG24N9K4/M=00 |
| R900958788 3DREPE6C-20=25EG24N9K31/A1M=00 |
| R901010402 3DREPE6A-20=25EG24N9K31/A1M=00 |
| R900958848 3DREPE6C-2X/25EG24N9K31/F1M |
| R900926984 3DREPE6C-2X/25EG24N9K31/F1V |
| R900954424 3DREPE6A-2X/45EG24K31/A1M |
| R901051881 3DREPE6A-2X/45EG24N9K31/A1M |
| R900978110 3DREPE6A-2X/45EG24N9K31/F1M |
| R901060430 3DREPE6B-2X/16EG24K31/A1M |
| R900956182 3DREPE6B-2X/25EG24K31/A1M |
| R900955862 3DREPE6B-2X/25EG24N9K31/A1M |
| R900931050 3DREPE6B-2X/25EG24N9K31/A1V |
| R900925013 3DREPE6B-2X/45EG24N9K31/A1V |
| R900929865 3DREPE6B-2X/45EG24N9K31/A1V=LB |
| R900573750 3DREP6C-1X/25A24N9K4V |
| R900551330 3DREP6C-1X/25A24NK4V |
| R900498485 3DREP6C-1X/25A12NK4M |
| R900494199 3DREP6A-1X/45A24NK4M |
| R900494195 3DREP6B-1X/45A24NK4M |
| R900494193 3DREP6B-1X/45A24K4M |
| R900494191 3DREP6C-1X/45A24NK4M |
| R900494190 3DREP6C-1X/45A24NK4V |
| R900494171 3DREP6B-1X/25A24NK4M |
| R900494167 3DREP6C-1X/25A24NK4M |
| R900494165 3DREP6C-1X/25A24K4M |
| R900494163 3DREP6A-1X/16A24NK4M |
| R900494155 3DREP6C-1X/16A24NK4M |
| R900494153 3DREP6C-1X/16A24K4M |
| R900484840 3DREP6C-1X/16A24NJM |
| R900451448 3DREP6A-1X/45A24N9K4M |
| R900956101 3DREP6C-20=25EG24N9K4/M=00 |
| R900954474 3DREP6A-2X/16EG24K4/M |
| R900954417 3DREP6A-2X/25EG24K4/M |
| R900954418 3DREP6A-2X/45EG24K4/M |
| R900954419 3DREP6C-2X/16EG24K4/M |
| R900954420 3DREP6C-2X/25EG24K4/M |
| R900954421 3DREP6C-2X/45EG24K4/M |
| R900550096 3DREP6C-1X/16A24N9K4M |
| R900547100 3DREP6C-1X/25A24N9K4M |
| R900498677 3DREP6A-1X/25A24NJM |
| R900498673 3DREP6C-1X/25A24NJM |
| R900498672 3DREP6C-1X/25A24JM |
| R900494189 3DREP6C-1X/45A24K4M |
| R900494175 3DREP6A-1X/25A24NK4M |
| R900576424 3DREP6C-1X/25A24N2JK10M |
FAQ: Rexroth 3DREP6C-2X/25EG24N9K4
What is this valve?
It is a direct-acting, 3-way proportional pressure reducing valve. It reduces a higher inlet pressure to a precisely controlled lower outlet pressure that is proportional to the electrical input signal.
What are its key features?
-
Direct-Acting Design: Provides fast response for low-pressure regulation (up to 25 bar).
-
3-Way Function: Can reduce pressure (P→A) or relieve pressure (A→T) depending on the signal polarity.
-
External Electronics: Requires an external amplifier card (e.g., VT-VSPA1) for operation.
How does it work?
The electrical signal (e.g., ±10V) controls the solenoid force. This force balances against the outlet pressure, setting it proportionally. A positive signal typically sets pressure from P to A, while a negative signal can relieve pressure from A to T.
Where is it typically used?
Commonly used in low-pressure pilot circuits, clamping applications, and secondary circuit pressure regulation where precise, variable control is needed.
How do I wire it?
-
Power: 24V DC to the external amplifier.
-
Signal: Connect the ±10V command signal to the amplifier inputs.
-
Valve: Connect the valve coil to the amplifier output (3-pole connector).
What if the pressure is unstable?
-
Ensure the external amplifier is correctly configured and powered.
-
Check for contamination, as small orifices are sensitive to dirt.
-
Verify that the inlet pressure is stable and significantly higher than the desired reduced pressure.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.