R900955784 3DREPE6C-2X/25EG24N9K31/A1M German Rexroth hydraulic proportional valve
|
Parameter |
Value / Description |
|---|---|
|
Order Code |
R900955784 |
|
Model |
3DREPE6C-2X/25EG24N9K31/A1M |
|
Type |
Direct-acting proportional pressure reducing valve (3-way) |
|
Size |
NG6 (CETOP 3) |
|
Max. Operating Pressure |
100 bar (P, A, B) |
|
Max. Flow Rate |
15 L/min |
|
Adjustable Pressure Range |
0 – 25 bar (proportional to signal) |
|
Mounting |
Subplate (ISO 4401-03-02-0-05) |
|
Control Type |
Proportional solenoid with integrated electronics (OBE) |
|
Supply Voltage |
24 V DC |
|
Command Signal |
±10 V (A1) |
|
Electrical Connector |
7-pin (6+PE) per EN 175201-804 (K31) |
|
Manual Override |
Yes, concealed (N9) |
|
Seals |
NBR (M) |
|
Weight |
Approx. 2.2 kg |
| R900547100 3DREP6C-1X/25A24N9K4M |
| R900498677 3DREP6A-1X/25A24NJM |
| R900498673 3DREP6C-1X/25A24NJM |
| R900498672 3DREP6C-1X/25A24JM |
| R900494189 3DREP6C-1X/45A24K4M |
| R900494175 3DREP6A-1X/25A24NK4M |
| R900576424 3DREP6C-1X/25A24N2JK10M |
| R900955887 3DREP6C-2X/25EG24N9K4/M |
| R900955862 3DREPE6B-2X/25EG24N9K31/A1M |
| R901015676 3DREPE6C-2X/16EG24N9K31/A1M |
| R901060430 3DREPE6B-2X/16EG24K31/A1M |
| R900956182 3DREPE6B-2X/25EG24K31/A1M |
| R901051881 3DREPE6A-2X/45EG24N9K31/A1M |
| R900978110 3DREPE6A-2X/45EG24N9K31/F1M |
| R901015676 3DREPE6C-2X/16EG24N9K31/A1M |
| R900954428 3DREPE6C-2X/45EG24K31/A1M |
| R900970698 3DREPE6C-2X/45EG24N9K31/F1V |
| R961000391 DICHTUNGSSATZ3DREP6.-2X/V |
| R961000390 DICHTUNGSSATZ3DREP6.-2X/M |
| R961000388 DICHTUNGSSATZ3DREP6.-1X/V |
| R961000330 DICHTUNGSSATZ3DREP6.-1X/M |
| R901094369 3DREPE6C-2X/45EG24K31/A1V |
| R901089114 3DREP6B-2X/16EG24N9K4/M |
| R901087988 3DREP6A-2X/16EG24N9K4/M-596 |
| R901077122 3DREP6B-2X/45EG24NJK31/M |
| R901015676 3DREPE6C-2X/16EG24N9K31/A1M |
| R901076954 3DREPE6B-2X/25EG24N9K31/F1M |
| R901060431 3DREPE6B-2X/45EG24K31/A1M |
| R901052777 3DREP6A-2X/45EG24XEJ/V |
| R901051881 3DREPE6A-2X/45EG24N9K31/A1M |
| R901033013 3DREPE6A-2X/25EG24N9K31/F1M |
| R901025350 3DREP6C-2X/25EG24XEJ/V |
| R901025332 3DREP6A-2X/25EG24XEJ/V |
| R901025268 3DREP6C-2X/45EG24XEJ/V |
| R900955887 3DREP6C-2X/25EG24N9K4/M |
| R900967550 3DREP6A-1X/25A24NK4M-596 |
| R900967209 3DREP6A-2X/16EG24N9K4/V |
| R900964865 3DREP6B-2X/25EG24K4/M |
| R900962045 3DREP6A-2X/45EG24N9K4/M |
| R900961820 3DREP6C-2X/25EG24NJK31/V |
| R900960161 3DREP6B-1X/45A24N9K4M |
| R900959741 3DREP6C-1X/45A24N9K4M |
| R900956100 3DREP6C-2X/16EG24N9K4/M |
| R900955887 3DREP6C-2X/25EG24N9K4/M |
| R900955887 3DREP6C-21=25EG24N9K4/M |
| R900955803 3DREP6A-2X/25EG24N9K4/M |
| R900955796 3DREP6C-2X/45EG24N9K4/M |
FAQ: Rexroth 3DREPE6C-2X/25EG24N9K31/A1M
What is this valve?
It is a direct-acting, 3-way proportional pressure reducing valve with integrated electronics (OBE). It converts an electrical input signal into a precisely controlled, reduced hydraulic pressure.
What are its key features?
-
Integrated Electronics (OBE): The amplifier is built into the solenoid, eliminating the need for an external amplifier card.
-
3-Way Function: Can reduce pressure (P→A/B) or relieve pressure (A/B→T) depending on the solenoid actuation.
-
Manual Override: Includes a concealed manual override (N9) for testing or emergency operation.
-
Compact Size: NG6 size ideal for low to medium flow pilot circuits.
How does it work?
The electrical command signal (±10V) controls the solenoid force, which sets the reduced outlet pressure proportionally. When de-energized, the valve center position connects the outlet ports (A, B) to the tank (T) for safe pressure release.
Where is it typically used?
Commonly used in low-pressure pilot circuits, clamping applications, and secondary circuit pressure regulation where precise, variable control and compact design are required.
How do I wire it?
-
Power & Signal: Supply 24V DC and the ±10V command signal directly to the 7-pin connector on the valve (no external amplifier needed).
-
Drain: Ensure the tank port (T) is connected directly to the reservoir with minimal backpressure.
What if the pressure is unstable or incorrect?
-
Verify the ±10V command signal is stable and within range.
-
Check for contamination, as the small orifices in direct-acting valves are highly sensitive to dirt.
-
Ensure the inlet pressure is stable and significantly higher than the desired reduced pressure.
-
Confirm the tank line (T) is not blocked and has low backpressure.
Get in Touch