R902520809 AA10VS071DRS/32R-VPB22U00E-S2183 German Rexroth piston pump
|
Parameter |
Specification |
|---|---|
|
Order Number |
R902520809 |
|
Model |
AA10VSO71DRS/32R-VPB22U00E-S2183 |
|
Type |
Variable displacement axial piston pump (swashplate design, open circuit) |
|
Nominal Displacement |
71 cm³/rev |
|
Control Type |
DRS (Pressure & Flow Control / Load Sensing) |
|
Pressure Rating |
280 bar (Continuous) |
|
Speed Range |
1000 – 1800 rpm (Recommended) |
|
Rotation Direction |
Right-hand (R) (viewed from shaft end) |
|
Shaft Type |
Splined shaft (SAE J744) |
|
Port Connection |
VPB22U (SAE flange with metric threads, with through-drive) |
|
Mounting Flange |
ISO 3019-2 (Series 32) |
|
Seal Material |
NBR (Standard for mineral oil) |
|
Suitable Media |
Mineral oils (HL, HLP), HLP-D, HVLP, HFC fluids |
|
Media Temperature |
-20°C to +80°C (Start-up viscosity < 1000 mm²/s) |
|
Recommended Viscosity |
16 – 68 mm²/s (ISO VG 32–68) |
|
Cleanliness Requirement |
ISO 4406 20/18/15 or better |
|
Weight |
Approx. 47 – 52 kg |
| R910908268 A A10VSO 45 DFR /31R-PPA12K25 |
| R902432094 A A10VSO 45 DFR /31R-PPA12KB2 |
| R910939183 A A10VSO 45 DFR /31R-PPA12N00 |
| R910920174 A A10VSO 45 DFR /31R-VPA12N00 |
| R902480875 A A10VSO 45 DFR /31R-VSA12KB4 |
| R910988591 A A10VSO 45 DFR1/31L-PPA12N00 -SO 32 |
| R910908416 A A10VSO 45 DFR1/31R-PPA12K01 |
| R910927068 A A10VSO 45 DFR1/31R-PPA12K02 |
| R910997719 A A10VSO 45 DFR1/31R-PPA12K04 |
| R910937937 A A10VSO 45 DFR1/31R-PPA12K51 |
| R910974772 A A10VSO 45 DFR1/31R-PPA12KB3 |
| R910970379 A A10VSO 45 DFR1/31R-PPA12KB4 |
| R910908725 A A10VSO 45 DFR1/31R-PPA12N00 |
| R910978723 A A10VSO 45 DFR1/31R-PSA12N00 |
| R910949909 A A10VSO 45 DFR1/31R-VPA12K02 |
| R910965714 A A10VSO 45 DG /31R-VPA12N00 |
| R910942498 A A10VSO 45 DR /31L-VPA12N00 |
| R910908273 A A10VSO 45 DR /31R-PPA12K01 |
| R910969378 A A10VSO 45 DR /31R-PSA12N00 |
| R910916629 A A10VSO 45 DR /31R-VPA12N00 |
| R910940863 A A10VSO 45 DRG /31R-PPA12N00 |
| R902456127 A A10VSO 45 DRG /31R-VPA12K68 |
| R910948800 A A10VSO 71 DFLR/31R-PPA12K00 -SO290 |
| R910947239 A A10VSO 71 DFLR/31R-PPA12K01 |
| R910944067 A A10VSO 71 DFLR/31R-PPA12N00 |
| R910946787 A A10VSO 71 DFR /31L-PPA12N00 |
| R910960472 A A10VSO 71 DFR /31R-PPA12K01 |
| R910963914 A A10VSO 71 DFR /31R-PPA12K02 |
| R902416246 A A10VSO 71 DFR /31R-PPA12K07 |
| R902428830 A A10VSO 71 DFR /31R-PPA12K52 |
| R910942635 A A10VSO 71 DFR /31R-PPA12N00 |
| R902439238 A A10VSO 71 DFR /31R-PSA12K07 -S1627 |
| R910960746 A A10VSO 71 DFR1/31L-PPA12N00 |
| R910947985 A A10VSO 71 DFR1/31R-PPA12K01 |
| R910947872 A A10VSO 71 DFR1/31R-PPA12K02 |
| R910966909 A A10VSO 71 DFR1/31R-PPA12K04 |
| R910963378 A A10VSO 71 DFR1/31R-PPA12K07 |
| R910991723 A A10VSO 71 DFR1/31R-PPA12KB3 |
| R910978724 A A10VSO 71 DFR1/31R-PPA12KB4 |
| R910968700 A A10VSO 71 DFR1/31R-PPA12KB5 |
| R910944440 A A10VSO 71 DFR1/31R-PPA12N00 |
| R910947992 A A10VSO 71 DFR1/31R-PPA12N00 -SO 20 |
| R910968701 A A10VSO 71 DFR1/31R-PSA12N00 |
| R910986932 A A10VSO 71 DFR1/31R-VPA12K01 |
| R910992519 A A10VSO 71 DFR1/31R-VPA12N00 |
| R902473183 A A10VSO 71 DFR1/31R-VPA42K27 |
| R902488176 A A10VSO 71 DFR1/31R-VPA42KB5 -SO 52 |
| R902501568 A A10VSO 71 DFR1/31R-VSA12N00 |
| R910960333 A A10VSO 71 DR /31L-VPA12N00 |
| R910998793 A A10VSO 71 DR /31R-PPA12N00 -SO108 |
| R910947219 A A10VSO 71 DR /31R-VPA12N00 |
| R902473969 A A10VSO 71 DR /31R-VPA42KB5 |
| R902482660 A A10VSO 71 DR /31R-VPA42N00 |
| R910947898 A A10VSO 71 DRG /31R-PPA12N00 |
| R910992951 A A10VSO 71 DRG /31R-PSA12N00 |
| R902411494 A A10VSO 71 DRG /31R-VPA12K02 |
| R910947258 A A10VSO 71 DRG /31R-VPA12N00 |
| R902452789 A A10VSO 71 DRS /32R-VPB22U99 |
| R902486410 A A10VSO 71 DRS /32R-VRB32U01 -SO 52 |
| R902486409 A A10VSO 71 DRS /32R-VRB32U68 -SO 52 |
| R910961157 A A10VSO 71 FHD /31R-PPA12N00 |
| R902460926 A A10VSO100 DFLR/31R-VPA12N00 |
| R910907813 A A10VSO100 DFR /31L-PPA12N00 |
| R910917313 A A10VSO100 DFR /31R-PPA12K01 |
| R910998331 A A10VSO100 DFR /31R-PPA12K07 |
| R910942637 A A10VSO100 DFR /31R-PPA12K27 |
| R902417327 A A10VSO100 DFR /31R-PPA12KB4 |
| R902416469 A A10VSO100 DFR /31R-PPA12KB5 |
| R910939643 A A10VSO100 DFR /31R-PPA12N00 |
| R910991002 A A10VSO100 DFR /31R-PSA12N00 |
| R910920969 A A10VSO100 DFR /31R-VPA12N00 |
| R910986270 A A10VSO100 DFR1/31L-PPA12KB4 -SO 32 |
| R910911394 A A10VSO100 DFR1/31R-PPA12K01 |
| R910927083 A A10VSO100 DFR1/31R-PPA12K02 |
| R910983124 A A10VSO100 DFR1/31R-PPA12KB3 |
| R910984741 A A10VSO100 DFR1/31R-PPA12KB4 |
| R910985609 A A10VSO100 DFR1/31R-PPA12KB5 |
| R902403231 A A10VSO100 DFR1/31R-PPA12KB6 |
| R910922744 A A10VSO100 DFR1/31R-PPA12N00 |
| R902418759 A A10VSO100 DFR1/31R-PSA12KB4 |
| R910971805 A A10VSO100 DFR1/31R-PSA12KB6 |
| R910949826 A A10VSO100 DFR1/31R-PSA12N00 |
| R910922681 A A10VSO100 DR /31L-VPA12N00 |
| R910968839 A A10VSO100 DR /31R-PPA12K04 |
| R910916809 A A10VSO100 DR /31R-VPA12N00 |
| R910943447 A A10VSO100 DRG /31R-PPA12N00 |
| R902420121 A A10VSO100 DRG /31R-VPA12K25 |
| R910930899 A A10VSO100 DRG /31R-VPA12N00 |
| R902448357 A A10VSO100 DRG /32R-VPB12N00 |
| R902454561 A A10VSO100 DRS/32R-VPB22U99 |
FAQ:
1. What is DRS control, and how does it work?
DRS is a combined pressure-flow control with load sensing (LS).
-
Pressure Control: Limits system pressure to a set maximum (like a DR control).
-
Flow Control (LS): The pump automatically adjusts its swashplate angle to deliver only the flow required by the actuators, maintaining a constant pressure differential (Δp) across the control orifice. This results in significant energy savings compared to constant flow pumps.
2. Can I mount an additional pump on the back?
Yes. The code VPB22U indicates this pump has a through-drive shaft (through-drive). You can mount a second pump (e.g., a gear pump for pilot flow or a second circuit) directly onto the back flange of this unit.
3. What are the critical installation precautions?
-
Case Drain (L port): Must be connected separately to tank with minimal backpressure (max 2–3 bar). Do not tee it into the main return line. This is critical for flushing heat and preventing seal/bearing failure.
-
Suction Conditions: Ensure inlet pressure at port S is ≥ -0.8 bar (absolute) to avoid cavitation. Use short, large-diameter suction lines.
-
Rotation: Confirm motor rotation matches the pump's "R" (clockwise) designation. Running backwards can destroy the pump.
4. Why is my pump noisy or overheating?
-
Noise: Usually caused by cavitation. Check suction filter, inlet line for leaks, or oil viscosity being too high at startup.
-
Overheating: Often due to excessive case pressure (blocked or undersized case drain line) or operating for long periods at high pressure with small displacement (high power loss).
5. How do I adjust the pressure setting?
The DRS control has a pressure limiter screw (usually under a cap on the control housing). Always adjust under controlled conditions with a pressure gauge:
-
Loosen the locknut.
-
Turn the screw clockwise to increase pressure, counterclockwise to decrease.
-
Tighten the locknut and re-check the setting.
6. Is an external relief valve still needed?
Yes. While the DRS control limits pressure, it is not a safety valve. You must install a separate system relief valve (e.g., a DB/DBW type) in the main line as a safety backup against control failure.
7. What is the difference between DR and DRS?
-
DR: Only pressure control (constant pressure variable pump).
-
DRS: Pressure control + Load Sensing. DRS adds the ability to match flow to demand, which is more energy-efficient for systems with varying flow requirements.
Disclaimer: For precise installation and commissioning, always refer to the official Rexroth technical data sheet RE 25700 for A10VSO Series 32 pumps.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.