R900912860 DBW20B2-5X/200-6EG24N9K4 Rexroth electromagnetic overflow valve made in Germany
Price:
Negotiable
MOQ:
1
Delivery Time:
2 weeks
Brand:
Rexroth
Product Description
R900912860 DBW20B2-5X/200-6EG24N9K4 Rexroth Electromagnetic Overflow Valve
Pilot-operated pressure relief valve with integrated solenoid unloading, manufactured in Germany.
| Parameter | Value |
|---|---|
| Part Number | R900912860 |
| Model | DBW 20 - B2 - 5X / 200 - 6EG24N9K4 |
| Valve Type | Pilot-operated pressure relief valve with integrated solenoid unloading (DBW series) |
| Nominal Size (NG) | 20 – subplate mounting per ISO 6264 / NG20 |
| Function | Pressure limiting at set value + solenoid-actuated system unloading (energize → P→T open, system near 0 bar) |
| Adjustment Type | B2 = Rotary hand knob with protective cap (hand-adjustable, no tool; B-version has different pilot damping orifice vs A-version) |
| Component Series | 5X (series 50-59, dimensionally interchangeable) |
| Max. Adjustable Relief Pressure | 200 bar (adjustment range typically 4-200 bar) |
| Max. Operating Pressure (P-port) | 350 bar |
| Max. Flow Rate (Qmax) | approx. 500 L/min (Size 20 DB/DBW series) |
| Pilot Oil | Internal pilot supply, internal pilot drain (standard DBW) |
| Solenoid Type | Wet-pin DC solenoid |
| Solenoid Voltage | 24 V DC (G24) |
| Electrical Connection | Plug-in socket per EN 175301-803 Form A (K4 = mating plug sold separately) |
| Manual Override | N9 = concealed push-button manual override on coil |
| Seal Material | NBR (standard, for mineral oil HL/HLP, HFC) |
| Hydraulic Fluid | Mineral oil HL, HLP per DIN 51524; HFC (water-glycol); HLPD, HVLP, HVLPD |
| Fluid Temperature Range | -30 °C to +80 °C (NBR seals) |
| Viscosity Range | 10-800 mm²/s |
| Weight (approx.) | 7.98 kg |
| Body Material | Cast iron / steel, zinc-plated |
Related Products
Frequently Asked Questions
Q1: What is the difference between A-version and B-version (DBW20A2 vs DBW20B2)?
Both are pilot-operated relief valves with solenoid unload and identical pressure/flow/solenoid specs. The B-version has a different pilot damping orifice which changes dynamic response (pressure overshoot, settling time). A-version is the general-purpose default; B-version is selected when system-specific stability tuning is needed. Externally both A2 and B2 have the same rotary hand knob adjustment.
Q2: Is this direct-acting or pilot-operated?
It is a pilot-operated (two-stage) relief valve with solenoid unloading. A pilot stage controls the main spool for stable high-flow relief; the integrated solenoid can command the valve to dump system pressure to tank.
Q3: How do I adjust the relief pressure?
With system depressurized, lift/remove the protective cap and turn the rotary knob clockwise to increase, counterclockwise to decrease. Factory preset is typically near minimum of the spring range. Replace the cap after setting and verify with a pressure gauge. The solenoid does NOT alter the set pressure.
Q4: What is the solenoid logic?
Standard: Solenoid DE-energized = relief active at set pressure. Solenoid ENERGIZED = system unloaded (P connected to T, near tank pressure). Confirm this matches your control logic before wiring.
Q5: Which subplate and electrical connector are needed?
- Subplate: standard NG20 (ISO 6264) with P and T ports (G 3/4" BSP or M27×2 on subplate), four M12 bolts @ ~70-80 N*m
- Electrical: EN 175301-803 Form A (DIN 43650-A) 3-pin + PE connector, 24 V DC. If the plug has LED indication, observe (+) / (-) polarity markings
Q6: Common faults & causes?
- Solenoid clicks but system does NOT unload: pilot orifice clogged, main spool stuck, no coil current (check ~18-28 Ω), manual override jammed
- Pressure won't reach set value / creeps early: wrong spring (not /200), pilot damping hole blocked, contaminated pilot seat, excessive T-backpressure (internal pilot drain)
- Coil overheats / burnt smell: overvoltage (>10% above 24V), wrong voltage coil fitted – replace only with correct G24 wet-pin coil
- Chatter / unstable: air in system, high T-backpressure, worn pilot seat – bleed air first
Q7: Does T-port backpressure affect set pressure?
Yes – this model has internal pilot drain. Backpressure at T adds 1:1 to the relief setpoint. If your tank line has >5 bar sustained backpressure, consider the DBW…Y version (external pilot drain to separate tank line).
Q8: Fluid & seal compatibility?
NBR seals = mineral oil (HL/HLP) & HFC (water-glycol). For HEES/HETG biodegradable oils or HFD phosphate ester → specify FKM (Viton) seal variant. Maintain oil cleanliness per ISO 4406 code 18/16/13 or better.
Need the Rexroth DB/DBW series datasheet (RE 25802) or NG20 subplate machining dimensions? Just let me know.