R900907684 DBW20B2-5X/315-6EG24N9K4 Electromagnetic overflow valve manufactured by Rexroth in Germany
Price:
Negotiable
MOQ:
1
Delivery Time:
2 weeks
Brand:
Rexroth
Product Description
R900907684 DBW20B2-5X/315-6EG24N9K4 Electromagnetic Overflow Valve
Manufactured by Rexroth in Germany - Pilot-operated pressure relief valve with integrated solenoid unloading
| Parameter | Value |
|---|---|
| Part Number | R900907684 |
| Model | DBW 20 - B2 - 5X / 315 - 6EG24N9K4 |
| Valve Type | Pilot-operated pressure relief valve with integrated solenoid unloading (DBW series) |
| Nominal Size (NG) | 20 - subplate mounting per ISO 6264 / NG20 |
| Function | Pressure limiting at set value + solenoid-actuated system unloading (energize → P→T open, system near 0 bar) |
| Adjustment Type | B2 = Rotary hand knob with protective cap (hand-adjustable, no tool; B-version has different pilot damping orifice vs A-version) |
| Component Series | 5X (series 50-59, dimensionally interchangeable) |
| Max. Adjustable Relief Pressure | 315 bar (adjustment range typically 4-315 bar) |
| Max. Operating Pressure (P-port) | 350 bar |
| Max. Flow Rate (Qmax) | approx. 500 L/min (Size 20 DB/DBW series) |
| Pilot Oil | Internal pilot supply, internal pilot drain (standard DBW) |
| Solenoid Type | Wet-pin DC solenoid |
| Solenoid Voltage | 24 V DC (G24) |
| Electrical Connection | Plug-in socket per EN 175301-803 Form A (K4 = mating plug sold separately) |
| Manual Override | N9 = concealed push-button manual override on coil |
| Seal Material | NBR (standard, for mineral oil HL/HLP, HFC) |
| Hydraulic Fluid | Mineral oil HL, HLP per DIN 51524; HFC (water-glycol); HLPD, HVLP, HVLPD |
| Fluid Temperature Range | -30 °C to +80 °C (NBR seals) |
| Viscosity Range | 10-800 mm²/s |
| Weight (approx.) | 8.0 kg |
| Body Material | Cast iron / steel, zinc-plated |
Related Part Numbers
R901368371 4WREE6W1-32-2X/G24K31/A1M
R900913359 4WREE6W1-32-2X/G24K31/A1V
R901362947 4WREE6W1-32-2X/G24K31/A1V-660
R901354752 4WREE6W1-32-2X/G24K31/F1M
R900933476 4WREE6W1-32-2X/G24K31/F1V
R900925657 4WREE6W16-2X/G24K31/A1V
R901048039 4WREE6W16-2X/G24K31/A1V=LB
R901362073 4WREE6W16-2X/G24K31/F1M
R900950416 4WREE6W16-2X/G24K31/F1V
R900929205 4WREE6W2-32-2X/G24K31/A1V
R900911004 4WREE6W32-2X/G24K31/A1V
R978902911 4WREE6W32-2X/G24K31/A1VSO43A-1539
R900969483 4WREE6W32-2X/G24K31/A1V=DE
R900938299 4WREE6W32-2X/G24K31/A1V=LB
R901438225 4WREE6W32-2X/G24K31/A1V=PL
R901354753 4WREE6W32-2X/G24K31/F1M
R900246793 4WREE6W32-2X/G24K31/F1V
R901355277 4WREE6W32-2X=G24K31/A1V
R900761481 4WREE6W9-16-2X/G24K31/A1V
R900783449 4WREE6W9-32-2X/G24K31/A1V
R901185980 4WREE6WA04-2X/G24K31/F1V
R900973482 4WREE6WA08-2X/G24K31/A1V
R901180378 4WREE6WA08-2X/G24K31/F1V
R900974247 4WREE6WA16-2X/G24K31/A1V
R900617766 4WREE6WA16-2X/G24K31/F1V
R900926997 4WREE6WA32-2X/G24K31/A1V
R900964934 4WREE6WA32-2X/G24K31/F1V
R900780141 4WREE6WB32-2X/G24K31/A1V
R978907329 4WREE10E50-2X/G24K31/A1VSO43A-1595
R978900573 4WREE10V75-2X/G24K31/A1VSO43A-1505
R987373453 4WREE10V75-2X/G24K31/A1V-S047-906
R978902912 4WREE10W75-2X/G24K31/A1VSO43A-1547
R978919605 4WREE10W75-2X/G24K31/A1VSO43A-1733
R978014651 4WREE6V08-2X/G24K31/F1VSO43A-1485
R978008628 4WREE6V08-2X/G24K31/F1VSO43A-1639
R978915950 4WREE6V16-2X/G24K31/A1VSO43A-1639
R978917001 4WREE6V16-2X/G24K31/F1VSO43A-1639
R978899985 4WREE6V32-2X/G24K31/A1VSO43A-1485
R978912989 4WREE6V32-2X/G24K31/F1VSO43A-1639
R901395707 4WREEM10E1-25-2X/G24K34/B6V
R900787894 4WREEM10E1-50-2X/G24K34/B6V
R901090746 4WREEM10E1-75-2X/G24K34/B6V
R901246417 4WREEM10E1-75-2X=G24K34/B6V
R900727833 4WREEM10E25-2X/G24K34/B6V
R900246856 4WREEM10E50-2X/G24K34/B6V
R900246617 4WREEM10E75-2X/G24K34/B6V
R901084068 4WREEM10R3-75-2X/G24K34/B6V
R901030889 4WREEM10W1-50-2X/G24K34/B6V
R901083029 4WREEM10W1-75-2X/G24K34/B6V
R901199059 4WREEM10W25-2X/G24K34/B6V
Frequently Asked Questions
Q1: What is the difference between A-version and B-version (DBW20A2 vs DBW20B2)?
Both are pilot-operated relief valves with solenoid unload and identical pressure/flow/solenoid specs. The B-version has a different pilot damping orifice which changes dynamic response (pressure overshoot, settling time). A-version is the general-purpose default; B-version is selected when system-specific stability tuning is needed. Externally both A2 and B2 have the same rotary hand knob adjustment.
Q2: Is this direct-acting or pilot-operated?
It is a pilot-operated (two-stage) relief valve with solenoid unloading. A pilot stage controls the main spool for stable high-flow relief; the integrated solenoid can command the valve to dump system pressure to tank.
Q3: How do I adjust the relief pressure?
With system depressurized, lift/remove the protective cap and turn the rotary knob clockwise to increase, counterclockwise to decrease. Factory preset is typically near minimum of the spring range. Replace the cap after setting and verify with a pressure gauge. The solenoid does NOT alter the set pressure.
Q4: What is the solenoid logic?
Standard: Solenoid DE-energized = relief active at set pressure. Solenoid ENERGIZED = system unloaded (P connected to T, near tank pressure). Confirm this matches your control logic before wiring.
Q5: Which subplate and electrical connector are needed?
• Subplate: standard NG20 (ISO 6264) with P and T ports (G 3/4" BSP or M27×2 on subplate), four M12 bolts @ ~70-80 N*m.
• Electrical: EN 175301-803 Form A (DIN 43650-A) 3-pin + PE connector, 24 V DC. If the plug has LED indication, observe (+) / (-) polarity markings.
• Electrical: EN 175301-803 Form A (DIN 43650-A) 3-pin + PE connector, 24 V DC. If the plug has LED indication, observe (+) / (-) polarity markings.
Q6: Common faults & causes?
• Solenoid clicks but system does NOT unload: pilot orifice clogged, main spool stuck, no coil current (check ~18-28 Ω), manual override jammed.
• Pressure won't reach set value / creeps early: wrong spring (not /315), pilot damping hole blocked, contaminated pilot seat, excessive T-backpressure (internal pilot drain).
• Coil overheats / burnt smell: overvoltage (>10% above 24V), wrong voltage coil fitted -- replace only with correct G24 wet-pin coil.
• Chatter / unstable: air in system, high T-backpressure, worn pilot seat -- bleed air first.
• Pressure won't reach set value / creeps early: wrong spring (not /315), pilot damping hole blocked, contaminated pilot seat, excessive T-backpressure (internal pilot drain).
• Coil overheats / burnt smell: overvoltage (>10% above 24V), wrong voltage coil fitted -- replace only with correct G24 wet-pin coil.
• Chatter / unstable: air in system, high T-backpressure, worn pilot seat -- bleed air first.
Q7: Does T-port backpressure affect set pressure?
Yes -- this model has internal pilot drain. Backpressure at T adds 1:1 to the relief setpoint. If your tank line has >5 bar sustained backpressure, consider the DBW…Y version (external pilot drain to separate tank line).
Q8: Fluid & seal compatibility?
NBR seals = mineral oil (HL/HLP) & HFC (water-glycol). For HEES/HETG biodegradable oils or HFD phosphate ester → specify FKM (Viton) seal variant. Maintain oil cleanliness per ISO 4406 code 18/16/13 or better.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location
Nan'an, Fujian Province, China
Contact Person
liyun