Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
                                                                                                           
Verified Supplier
Years
Since
Menu

R900423213 ZDR6DA2-4X/210YM Direct acting pressure reducing valve, German original Rexroth

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 2 weeks
Brand: Rexroth
Product Description
R900423213 ZDR6DA2-4X/210YM Direct Acting Pressure Reducing Valve

German original Rexroth direct-acting, 3-way pressure reducing valve designed for sandwich mounting. Reduces and maintains pressure in secondary circuits to a set value while dumping excess flow via external drain.

Technical Specifications
Part Number R900423213
Model ZDR 6 - DA2 - 4X / 210YM
Valve Type Direct-acting, 3-way pressure reducing valve (sandwich/stackable)
Nominal Size (NG) 6 - sandwich mounting per ISO 5781 / NG6 (DIN 24340 Form E)
Function Reduces & maintains pressure in secondary circuit to set value; 3-way action (excess dumps via external drain)
Adjustment Type DA2 = Rotary hand knob with protective cap (hand-adjustable, no tool)
Component Series 4X (series 40-49, dimensionally interchangeable)
Max. Adjustable Reduced Pressure 210 bar (adj. range typically 4-210 bar)
Max. Operating Pressure (Primary P-port) 315 bar
Max. Operating Pressure (Secondary port) 315 bar
Max. Flow Rate (Qmax) approx. 60 L/min (Size 6 ZDR)
Pilot Oil Drain Y = External pilot drain (separate Y-port to tank)
Seal Material M = FKM (Viton) - specified by "M" in ordering code
Hydraulic Fluid Mineral oil HL, HLP; HEES, HETG (bio-oils - FKM recommended); HFC (short-term OK, NBR preferred for prolonged HFC)
Fluid Temperature Range -20 °C to +90 °C (FKM seals)
Viscosity Range 10-800 mm²/s
Weight (approx.) 1.7 kg
Body Material Steel / cast iron, zinc-plated
Rexroth ZDR6DA2-4X/210YM Pressure Reducing Valve
Related Part Numbers
R901382353 4WRPEH6CB40L-3X/M/24A1
R901382354 4WRPEH6CB40L-3X/M/24F1
R901382356 4WRPEH6C4B02L-3X/M/24A1
R901382357 4WRPEH6C3B25P-3X/M/24A1
R901382358 4WRPEH6C3B40P-3X/M/24A1
R901382359 4WRPEH6C4B15P-3X/M/24A1
R901382361 4WRPEH6C4B25P-3X/M/24A1
R901382363 4WRPEH6C4B40P-3X/M/24A1
R901382364 4WRPEH6C5B40P-3X/M/24A1
R901382365 4WRPEH6CB04L-3X/M/24A1
R901382367 4WRPEH6C3B02L-3X/M/24A1
R901382368 4WRPEH6C5B40L-3X/M/24A1
R901382369 4WRPEH6C5B40L-3X/M/24F1
R901382370 4WRPEH6C5B24L-3X/M/24A1
R901382371 4WRPEH6CB12L-3X/M/24F1
R901382372 4WRPEH6CB24L-3X/M/24F1
R901382374 4WRPEH6CB04L-3X/M/24F1
R901382375 4WRPEH6CB40P-3X/M/24F1
R901382376 4WRPEH6CB02L-3X/M/24F1
R901382487 4WRPEH6C1B40L-3X/M/24F1
R901382488 4WRPEH6C3B04L-3X/V/24A1
R901382489 4WRPEH6C6B02L-3X/M/24A1
R901382490 4WRPEH6CB25P-3X/M/24A1
R901382491 4WRPEH6C1B24L-3X/M/24F1
R901382492 4WRPEH6CB04P-3X/M/24A1
R901382493 4WRPEH6C4B40L-3X/V/24A1
R901382495 4WRPEH6C1B40P-3X/M/24A1
R901382496 4WRPEH6C3B04P-3X/V/24A1
R901382502 4WRPEH6C3B04P-3X/M/24F1
R901382503 4WRPEH6C3B12L-3X/V/24A1
R901382504 4WRPEH6C3B08L-3X/V/24F1
R901382505 4WRPEH6CB04L-3X/V/24F1
R901382509 4WRPEH6C4B40L-3X/V/24F1
R901382510 4WRPEH6C5B24L-3X/M/24F1
R901382511 4WRPEH6C3B15P-3X/M/24F1
R901382512 4WRPEH6C4B40P-3X/M/24F1
R901382513 4WRPEH6C3B12L-3X/V/24F1
R901382514 4WRPEH6C3B04L-3X/V/24F1
R901382515 4WRPEH6C5B04L-3X/M/24F1
R901382516 4WRPEH6C3B40L-3X/V/24F1
R901382517 4WRPEH6C5B12L-3X/M/24F1
R901382519 4WRPEH6C5B12L-3X/M/24A1
R901382520 4WRPEH6CB02L-3X/M/24A1
R901382521 4WRPEH6C4B15P-3X/M/24F1
R901382522 4WRPEH6C3B15P-3X/V/24A1
R901382523 4WRPEH6C4B24L-3X/V/24F1
R901382524 4WRPEH6C5B04L-3X/M/24A1
R901382525 4WRPEH6C4B02L-3X/V/24F1
R901382526 4WRPEH6CB24L-3X/V/24F1
R901382527 4WRPEH6C1B24L-3X/M/24A1
R901382528 4WRPEH6C4B04L-3X/V/24F1
R901382530 4WRPEH6CB15P-3X/M/24A1
R901382532 4WRPEH6C4B25P-3X/M/24F1
R901382533 4WRPEH6C4B04P-3X/M/24A1
R901382534 4WRPEH6C5B40L-3X/V/24F1
R901382535 4WRPEH6C3B25P-3X/M/24F1
R901382537 4WRPEH6C3B04P-3X/V/24F1
R901382538 4WRPEH6C1B12L-3X/M/24A1
R901382539 4WRPEH6C3B40P-3X/M/24F1
R901382630 4WRPEH6CB40P-3X/M/24A1
Frequently Asked Questions
Is ZDR a relief valve / overflow valve?

No. A relief valve (DB/DBD) limits upstream/system pressure; a pressure reducing valve (ZDR) maintains a lower, constant pressure in a downstream (secondary) circuit. If inlet (primary) pressure drops below the set reduced pressure, the ZDR opens fully and passes flow unregulated.

What does "DA2 /210YM" mean?
  • DA2 = NG6 sandwich, rotary hand knob with protective cap (hand-adjustable)
  • /210 = spring stage, max. adjustable reduced pressure = 210 bar (medium stage; others: /75, /150, /315)
  • Y = external pilot drain - pilot oil returns via separate Y-port to tank, not via sandwich T-channel
  • M = FKM (Viton) seal material
How do I adjust the reduced pressure?

With the secondary circuit under flow, lift/remove the cap and turn the rotary knob clockwise to increase, counterclockwise to decrease. Verify with a pressure gauge at the secondary port - the knob has no calibrated scale. Factory preset is typically near minimum; fine-tune under operating flow if possible.

How is the valve mounted?

As a sandwich (stackable) valve between a directional control valve and the NG6 subplate. Uses NG6 DIN 24340 Form E / ISO 5781 bolt pattern. Sandwich port IDs: P = primary (high pressure from pump side), A (or B) = reduced secondary pressure to actuator, T = tank return, Y = external pilot drain to tank (must be plumbed).

Why specify the "Y" (external drain) version?

If the T-line in the valve stack has >2-3 bar backpressure, an internally drained ZDR's set reduced pressure will increase by the amount of T-backpressure. The Y-version drains the pilot independently to tank, keeping the set reduced pressure stable. Always use Y-version if T-backpressure is present or uncertain.

What is the "M" seal version for?

M = FKM (Viton) seals - for:

  • Higher fluid temperature (up to ~90 °C)
  • Biodegradable oils (HEES, HETG - NBR not recommended)
  • Some HFC applications (short-term; NBR preferred for prolonged HFC exposure)

Not for phosphate ester (HFD) unless specially confirmed - standard NBR applies.

Common faults & causes?
  • Reduced pressure too high / cannot lower: wrong spring stage, pilot orifice clogged, Y-drain line blocked (Y-version!), inlet pressure insufficient
  • Reduced pressure drifts / unstable: contaminated pilot seat, damaged sandwich-face O-ring causing internal leak, Y-line restricted or pinched
  • Excessive heating at T: Normal for 3-way ZDR - some bypass to T occurs to hold set pressure; excessive heat may indicate stuck spool from contamination - flush system & verify filtration (ISO 4406 18/16/13 or better)
Can one ZDR reduce both A- and B-side pressure?

Standard ZDR6 sandwich reduces pressure in one working line (usually marked A on sandwich face). For independent A+B reduction use two ZDR6 valves or a custom manifold.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location Nan'an, Fujian Province, China
Contact Person liyun

Request A Quote

Please check your email address.
Your message must be at least 20 characters.