Manufacturer / Series Rexroth A4VSO Series - Swashplate Axial Piston Variable Displacement Pump, Open Circuit
Model Code A4VSO355 DRG / 30L-PPB25N00
Size (Nominal Displacement) 355 cm³/rev (Vg max)
Circuit Type Open Circuit
Control Type DRG - Pressure Compensator with Remote Pressure Setting (same as DR constant-pressure control, plus pilot port X for remote cut-off pressure adjustment via external relief valve or solenoid reducing valve)
Series 30 Series
Rotation L - Counter-Clockwise (viewed from shaft end)
Shaft P - Metric parallel keyed shaft (DIN 6885 plain shaft with key)
Mounting Flange B - ISO 4-bolt flange
Working Ports 25 - SAE Flange Ports (Pressure B = SAE 6000 psi 4-bolt flange, Suction S = SAE 3000 psi 4-bolt flange, side-mounted 90° apart)
Through-Drive / Aux Pump N00 - No through-drive, no auxiliary pump
Seal Material P - NBR (Nitrile, for mineral oil HLP); V = FKM(Viton) for HFC-compatible versions
Nominal Pressure 350 bar (35 MPa)
Peak / Max Pressure 400 bar (40 MPa)
Max. Speed (at Vg max) 1500 rpm (A4VSO355 size)
Nominal Flow ≈ 533 L/min @ 1500 rpm (Vg max)
Min. Inlet Pressure 0.8 ~ 2 bar absolute (self-priming, avoid cavitation)
Hydraulic Fluid Mineral oil (HL/HLP per DIN 51524); HFC only with V-seal version
Viscosity Range 10 - 1000 mm²/s (opt. 16-100 mm²/s)
Weight (approx.) ~207 kg
Origin Germany
Rexroth A4VSO355DRG hydraulic piston pump
Code Breakdown PPB25N00: P=Keyed shaft | P=NBR seal | B=ISO 4-hole flange | 25=SAE flange side ports (vs. "13" = metric threaded) | N00=No thru-drive aux pump.

DRG = DR pressure compensator with remote pilot port (X) -- the pressure cut-off setpoint can be shifted remotely by applying pilot pressure from an external valve, while the handwheel still acts as a mechanical maximum limit stop.
Frequently Asked Questions
Q1: What is the difference between DR, DRG, and DFR1 on A4VSO pumps?
  • DR (this model minus G): Direct-operated pressure compensator -- cut-off pressure set mechanically only via handwheel on pump.
  • DRG (this model): Same pressure compensator plus remote pilot port X -- an external relief or reducing valve can set/change the cut-off pressure remotely (e.g., dual-pressure staging via solenoid), while the handwheel sets the max safety limit.
  • DFR1: Pressure + Flow (Load Sense) controller -- maintains constant Δp for energy-saving flow control, more complex than DR/DRG.
Choose DRG when you need remotely switchable pressure setpoints in a constant-pressure system.
Q2: This model has "L" (counter-clockwise). Can I substitute an "R" (clockwise) version?
Only if your drive motor can be reversed. "L" = CCW viewed from shaft end, "R" = CW. Pump housings and port orientations are identical, but rotation direction is not interchangeable unless you change motor rotation. Always verify motor rotation before ordering.
Q3: Does A4VSO355 require a case drain line? How to plumb it?
Yes, a case drain (housing leakage / L-port) line is mandatory. Return it directly to tank above the oil level or via a standpipe ≤ 0.5 bar backpressure. Never block it or tee into the suction line -- excessive case pressure will blow the shaft seal. Fill the case with clean hydraulic oil before first start-up.
Q4: Port code "25" vs "13" -- what's the difference and what fittings do I need?
"13" = side ports with metric BSPP (G) threads; "25" = side ports with SAE 4-bolt flanges (Pressure port typically SAE Code 61 / 6000 psi, Suction SAE Code 62 / 3000 psi). This model uses "25" -- you need SAE split-flange halves and O-rings, not threaded adaptors.
Q5: How is the remote pressure setpoint (DRG) applied?
Connect a remote pilot relief/reducing valve to the X port on the DRG controller. Pilot pressure at X maps to pump cut-off pressure per the spring ratio (typically 0-10 bar pilot = 0-350 bar pump cut-off). The mechanical handwheel on the pump sets the upper limit -- the actual cut-off is the lower of the two (handwheel limit vs. pilot-derived setpoint).
Q6: Critical installation & filtration requirements?
  • Filtration: Maintain system cleanliness ≤ NAS 9 (≈ ISO 4406 17/15/12), 10 µm or finer return/full-flow filter.
  • Suction: Keep inlet line short and generously sized; min. inlet pressure 0.8 bar abs; 100-150 mesh suction strainer recommended.
  • Alignment: Flexible coupling only -- no radial/axial shaft loads from the motor.
  • Bleeding: Vent pump housing and system high-points before initial run to prevent air-lock/cavitation damage.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Location Nan'an, Fujian Province, China
Contact Person liyun

Request A Quote

Please check your email address.
Your message must be at least 20 characters.