A4VSO250EO2/30L-PPB13N00 Mining oilfield loader motor piston pump German Rexroth
| Model | A4VSO250EO2/30L-PPB13N00 |
|---|---|
| Brand / Origin | Rexroth / Germany |
| Type | Swashplate-type axial piston variable pump (Open circuit) |
| Displacement (Vg max) | 250 cm³/rev |
| Control Type | EO2 — Electro-proportional displacement control with higher pilot pressure requirement (min. pilot pressure typically 50 bar; pump flow ∝ electric command signal via external amplifier) |
| Nominal Pressure | 350 bar (35 MPa) Continuous |
| Peak Pressure | 400 bar (40 MPa) Intermittent |
| Max. Speed (nₘₐₓ) | 1500 rpm @ Vg max |
| Theoretical Flow @ 1500 rpm | ≈ 375 L/min (n × Vg ÷ 1000) |
| Rotation Direction | L — Counter-clockwise (viewed from shaft end) |
| Mounting Flange | ISO 3019-2 / Series 30, 4-bolt |
| Through-drive | Yes (PPB = through-drive capable; N00 = no auxiliary pump fitted) |
| Port Configuration | PPB13 — SAE flange side ports (P & T 90° apart), no extra B1 port |
| Seal Material | FKM (Viton, standard for mineral oil HLP / flame-retardant HFC with approval) |
| Case Drain | Two case drain ports — must be routed to tank < 2 bar backpressure |
| Recommended Viscosity | 16 - 100 mm²/s (ISO VG 46 @ operating temp) |
| Cleanliness Requirement | ISO 4406 18/16/13 (NAS 1638 Class 8-9) |
| Net Weight (Approx.) | ≈ 148 kg (dry, excl. coupling) |
| Package / Condition | Original factory wooden crate, new unused, German import |
| Salable / Supply Region | Global — Available via Rexroth authorized industrial hydraulics distributors |
Industrial / Stationary Use: Mining machinery hydraulic power units (HPU for roof supports test stands, crusher clamping systems), oilfield skid-mounted power packs, large loader/shovel auxiliary hydraulic stations, steel mill auxiliaries, plastic injection molding machines, die-casting presses, heavy test benches.

- A4VSO — Axial piston variable pump, open circuit
- 250 — Displacement 250 cm³/rev
- EO2 — Electro-proportional displacement control, high pilot pressure type (min. ~50 bar, often 100 bar for Size 250/355)
- 30 — Design Series 30
- L — Counter-clockwise rotation (viewed from shaft end)
- PPB13N00 — ISO flange w/ through-drive (PP), SAE side ports (B13), no auxiliary pump (N00)
- Mining: Used in mine hoist hydraulic clamps, crusher wedge adjusters, roof support test benches, or centralized mine-site hydraulic power stations where precise electrically controlled flow is needed. NOT typically the walking drive pump of continuous miners.
- Oilfield: Found on skid-mounted well-service HPUs, drawworks brake/clutch control packs, and BOP test rigs — anywhere an open-circuit variable flow pump with remote electric control is required.
- Loader / Wheel Loader: A4VSO is not the main travel pump of a wheel loader (that would be A4VG or A11VO). It can be used in:
- Loader manufacturer's factory test stands for validating steering/implement valves.
- Large loaders' auxiliary fixed HPUs (e.g., for specialized attachments powered from a separate pump pack).
- Retrofit situations where an industrial-style open-circuit variable pump is needed for attachment control.
Both are electro-proportional displacement controls (flow ∝ command signal, LVDT feedback onboard). Difference is pilot pressure requirement:
- EO1: Min. pilot ~20 bar (Sizes 40-250).
- EO2: Min. pilot ~50-100 bar (Sizes 250/355/500+, offers higher control stiffness).
For A4VSO250 with EO2, ensure your system can supply clean pilot oil at ≥ 50 bar (check nameplate — often 100 bar for Size 250 EO2).
Yes. The PPB code = through-drive capable. An A4VSO (same/smaller) or gear pump can be flange-mounted to the rear. N00 = no auxiliary pump pre-fitted, through-drive shaft present.
- Case Drain: Plumb directly to tank, backpressure ≤ 1.5-2 bar. Never tee into main return.
- Suction Line: Short & large-diameter; absolute inlet pressure ≥ 0.8 bar. Use 100 µm suction strainer.
- Pilot Pressure (EO2): Supply pilot port with clean oil at required min. pressure (typically 50-100 bar). Insufficient pilot pressure → swash plate won't stroke.
- Rotation Check: "L" = counter-clockwise from shaft end — verify prime mover direction.
- Bleed: Fill case and suction with oil, vent before first start-up.
Yes. Pump has solenoid + LVDT but requires an external proportional amplifier (e.g. Rexroth VT 5035-1X or PLC analog output with current driver) for the command signal and 24 V DC. Amplifier ordered separately.
Yes, absolutely. EO2 controls displacement/flow only — no pressure limiting. Install a properly sized system safety relief valve (e.g. DB type) set above max working pressure + ~10-15% margin.
Maintain ISO 4406 18/16/13 (NAS 1638 Class 8-9) minimum using return-line filter β₁₀ ≥ 200 (10 µm nominal). Contamination is the primary cause of A4VSO premature failure.
Mechanically yes (same flange, displacement, rotation). Electrically/hydraulically you must ensure your system can supply the higher pilot pressure required by EO2. If your original system was designed for EO1 (20 bar pilot), verify pilot source before substituting with EO2.
Get in Touch