Wind Energy Cable High And Low Temperature Torsion Resistance Testing Machine Is Applicable To The Torsion Resistance Test Of Twisted Flexible Cables Used In Wind Power Generation Systems
I. Scope of Application
It is applicable to the torsion resistance test of twisted flexible cables used in wind power generation systems or similar systems with a rated voltage of 1.8/3kV and below in low-temperature environments.
Ii. Compliance with Standards
TICW1-2009 Test Method for Torsion of Wind Power Generation Torsion-Resistant Flexible Cables
GB/T2423.1-2001 Test A: Low Temperature Test Method, GB/T2423.2-2001 Test B: High Temperature Test Method.
Iii. Technical Parameters
Studio dimensions: 400×300×2300mm;
Test channel: 300 × 300 × 12600 mm;
External dimensions: 1550×2500mm
Left height: 1720mm;
Right height: 9620mm;
The external dimensions of the left and right channels: 640×54mm;
Total mass: approximately 2,500 kg;
Cable testing range: Testing of wind energy cables below 35KV;
Temperature range: -60 to 8 ℃
Temperature fluctuation: ≤ ± 0.5 ℃
Temperature uniformity: ≤ ± 0.3 ℃
Heating time: Adjustable;
Cooling time: Average 0.7 to 1.0 ℃ /min;
Observation window: Multi-layer hollow, high-temperature resistant (500 ℃);
Glass window: (200 × 300) Twisted control cabinet, frame: 700 × 1300 × 1400;
Door opening: Single-hinged door;
Control panel: Power supply, controller display screen, control buttons;
Distribution control cabinet: distribution board, exhaust fan;
Heater: Stainless steel finned heater;
Fixture: One set of cable torsion fixture;
Power cord hole and drainage hole: Located on the back of the box.
Get in Touch