DX8315A UV Aging Test Chamber
This machine complies with EN ISO 12543‑4:2011 standard.
Application
This equipment is mainly used for UV aging test of laminated glass.
Detailed Technical Parameters
Work chamber dimension: 1100mm × 1100mm × 1000mm
Specimen test size: 300mm × 300mm
Test specimen quantity: 9 pcs
Sample surface temperature control range: 45 ℃ ± 5 ℃
Light source: OSRAM Ultra Vitalux 300W (domestic alternative available)
Quantity of UV lamps: 16 pcs
Total radiation intensity on specimen surface: 900 W/m² ±100 W/m²
Distance from sample to light source: more than 500 mm
Specified testing duration: 2000 h
Noise level: ≤75 dB
Fan power: ≤25 W × 4
Compressor power: 2.5 HP
Installed total power: 9 KW
Power supply: AC 380V / 50Hz, three‑phase five‑wire system