HDT VICAT Tester ISO 75 ASTM D 648 Apparatus for Testing Thermal Deformation and Softening Point of Plastics Rubber and Nylon
Overview

Primarily intended for non-metallic materials such as plastics, rubber and nylon, the ISO 75 ASTM D 648 Thermal Deformation HDT Vicat Apparatus Softening Point Test Machine also applies to electrical insulating materials. It is equipped with a function to adjust the test frame up or down at the start or conclusion of each test, and is specialized in conducting the determination of both thermal deformation temperature and Vicat softening point temperature for the aforementioned materials.

Product Introduction

The ISO 75 ASTM D 648 Thermal Deformation Vicat Softening Point Tester is engineered to keep pace with the rapid development of the plastics industry and elevate the standard of material research and testing. It complies with the latest international and national standards, including ISO 75-1:1993 (Plastics), GB/T 1633-2000 (Determination of Vicat Softening Temperature (VST) for Thermoplastic Materials) and GB/T 1634-2001 (Determination of Flexural Temperature Under Load for Plastics). Featuring computerized control, the tester delivers stable performance, user-friendly operation and a high degree of automation, making it the most advanced testing instrument for measuring the deflection temperature and Vicat softening temperature of non-metallic materials.

Test Standards

GB/T1633, GB/T1634, ISO75, ISO306, ASTM D648, ASTM D1525, ISO 2507

Technical Parameters
Model XRW-300F
Technical Data
  • Equipped with 6 stations (Ability to test 6 samples simultaneously)
  • Automatic performance: A left for moving the samples
  • Air above 150°C, 150°C the following water or natural cooling
  • Deformation measurement: High precision digital display dial gauge
  • Heating Rate: 50°C/h, 120°C/h
  • Max. Temperature Deviation: ±0.5°C
  • Deformation deviation: 0.001mm
  • Vicat load: 10N ± 0.2 N, 50N ± 1N
  • Fiber stress: 0.455 Mpa and 1.82 Mpa
  • Temperature-control Range: room temperature ~ 300°C
  • Deformation Measuring Range: 0 ~ 2mm
  • Sample Frame Number: 3~6
  • Test Span: 60~120mm
  • Heating Power: 6KW
  • Power Supply: 220V 50Hz
  • Display: Color touch screen
Type and Display Vertical type Using PC control system
Usage Used to measure heat deformation and Vicat softening temperature of thermoplastics material of plastic and rubber in the manufacturer, scientific research and colleges.
Configuration
  • Main frame: 1 set
  • Electric cabinet: 1 set
  • Specimen holder: 3 sets (or 6 sets)
  • Vicat indenter: 3 sets (or 6 sets)
  • Heat deflection indenter: 3 sets (or 6 sets)
  • Displacement sensor: 3 sets (or 6 sets)
  • Power line: 2 sets
  • Connecting line: 2 sets
  • Operation manual: 1 set
  • Certificate: 1 set
  • Packing list: 1 set
Frequently Asked Questions
Q1: What is the temperature resolution of the ISO 75 ASTM D 648 Thermal Deformation Vicat Softening Point Tester?
A1: The temperature resolution of this tester reaches 0.1°C, which ensures high-precision temperature monitoring during the entire testing process and effectively guarantees the accuracy of test results.
Q2: How many sample holders can the tester be equipped with at most?
A2: This Vicat thermal deformation tester can be configured with up to 3 independent sample holders, allowing simultaneous testing of multiple samples, which greatly improves testing efficiency.
Q3: What is the load accuracy of the tester for Vicat softening point and thermal deformation tests?
A3: The tester features a load accuracy of ±1%, which meets the strict requirement of relevant international and national standards and ensures the stability of load application during testing.
Q4: What kind of heating medium is applicable to this tester?
A4: It is compatible with two common heating media: silicone oil and glycerin, which can be selected according to different test materials and standard requirements to achieve uniform temperature distribution.
Q5: What is the displacement measurement range of the tester for thermal deformation testing?
A5: The displacement measurement range of the tester is 0-10 mm, with a displacement accuracy of 0.01 mm, which can accurately record the deformation of materials under high temperature conditions.
Product Images

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Beijing Tonghe Testing Machine Co., ltd
Location No. 1, Fengguan Road, Fengtai District, Beijing
Contact Person Zoe Bao

Request A Quote

Please check your email address.
Your message must be at least 20 characters.