Hot Sale For Holtop Vortex Module-Type Air-Cooled Chilled Water (Heat Pump) Unit HFW-840HA1
Price:
Negotiate
MOQ:
1pc
Delivery Time:
Negotiate
Brand:
Holtop
Product Description
Holtop Vortex Module-Type Air-Cooled Chilled Water (Heat Pump) Unit HFW-840HA1
The vortex module-type air-cooled chilled water (heat pump) unit utilizes advanced modular technology with air as the cooling and heating medium. This integrated central air conditioning equipment serves as both a cooling/heating source and combined unit. It can be paired with fan coil units, cabinet-type air handlers, ceiling-mounted air handling units, and fresh air units to create efficient semi-centralized air conditioning systems.
Key Product Features
- Modular Combination & Hierarchical Startup: Modular design allows flexible combinations without distinguishing between main and secondary machines. Supports up to 16 units per group with hierarchical startup to reduce current impact on power grids.
- Intelligent Defrosting: Multi-variable detection for precise frost determination and optimal defrost timing. Dual-system design enables interval defrosting with manual override capability in harsh conditions.
- Flexible Application: Easy unit expansion suitable for phased investment. Compact design allows independent transportation and installation without large equipment. End water inlet/outlet design reduces installation space requirements.
- Safe Operation Control: Comprehensive safety protection functions with intelligent multi-variable monitoring for efficient and stable operation.
- Fault Backup Operation: Dual-compressor design ensures continued operation if one compressor fails, maintaining system functionality.
Technical Specifications
| Rated Voltage | Three-phase 380V/3N~ |
| Rated Frequency | 50Hz |
| Power Supply Voltage | ±10% of rated voltage |
| Operating Conditions | See operating range tables |
| Storage Conditions | Environmental temperature: -28 to 85℃ |
| Control Method | Remote controller |
| Fan Type | Axial flow low-noise fan |
Operating Range
| Operating Condition | Outdoor Ambient Temperature | Outlet Water Temperature |
|---|---|---|
| Cooling | 15℃ ≤ Temperature ≤ 48℃ | 5℃ ≤ Temperature ≤ 15℃ |
| Heating | -15℃ ≤ Temperature ≤ 21℃ | 40℃ ≤ Temperature ≤ 50℃ |
Refrigeration System Performance Parameters
| Outlet Temperature (℃) | Environment Temperature (℃) | ||||
|---|---|---|---|---|---|
| 25 | 30 | 35 | 40 | 45 | |
| 5 | 1.07 | 1.00 | 0.94 | 0.84 | 0.81 |
| 6 | 1.10 | 1.03 | 0.97 | 0.87 | 0.83 |
| 7 | 1.14 | 1.07 | 1.00 | 0.91 | 0.86 |
| 8 | 1.17 | 1.10 | 1.03 | 0.94 | 0.88 |
| 9 | 1.20 | 1.13 | 1.06 | 0.98 | 0.91 |
| 10 | 1.23 | 1.16 | 1.09 | 1.01 | 0.93 |
| 11 | 1.27 | 1.19 | 1.12 | 1.04 | 0.96 |
| 12 | 1.31 | 1.23 | 1.15 | 1.07 | 0.99 |
| 13 | 1.34 | 1.26 | 1.17 | 1.09 | 1.01 |
| 14 | 1.37 | 1.29 | 1.20 | 1.12 | 1.03 |
| 15 | 1.41 | 1.32 | 1.23 | 1.14 | 1.06 |
Heating Mode Performance Parameters
| Outlet Temperature (℃) | Environment Temperature (℃) | |||||
|---|---|---|---|---|---|---|
| 15 | 10 | 7 | 0 | -5 | -10 | |
| 30 | 1.23 | 1.10 | 1.03 | 0.94 | 0.88 | 0.75 |
| 35 | 1.21 | 1.09 | 1.02 | 0.93 | 0.87 | 0.75 |
| 40 | 1.20 | 1.08 | 1.01 | 0.91 | 0.85 | 0.74 |
| 45 | 1.19 | 1.07 | 1.00 | 0.90 | 0.84 | 0.74 |
| 50 | 1.17 | 1.05 | 0.98 | 0.85 | 0.80 | 0.74 |
Large Vortex Modular Air-Cooled Chiller (Heat Pump) Unit Models
| Model | HFW-420HA1 | HFW-560HA1 | HFW-840HA1 | HFW-980HA1 | HFW-1120HA1 |
|---|---|---|---|---|---|
| Nominal Cooling Capacity (kW) | 420.0 | 560.0 | 840.0 | 980.0 | 1120.0 |
| Nominal Heating Capacity (kW) | 454.0 | 605.0 | 908.0 | 1059.0 | 1210.0 |
| Refrigeration Input Power (kW) | 129.2 | 172.3 | 258.4 | 301.5 | 344.6 |
| Heating Input Power (kW) | 132.4 | 176.4 | 264.8 | 308.8 | 352.8 |
| Compressor Quantity | 3 | 4 | 6 | 7 | 8 |
| Fan Power (kW) | 1.8x6 | 1.8x8 | 1.8x12 | 1.8x14 | 1.8x16 |
| Nominal Water Flow Rate (m³/h) | 72.2 | 96.3 | 144.4 | 168.5 | 192.6 |
| Dimensions LxWxH (mm) | 3540x2280x2540 | 4700x2280x2540 | 7080x2280x2540 | 8240x2280x2540 | 9400x2280x2540 |
| Weight (kg) | 4020/4160 | 5350/5540 | 8040/8320 | 9370/9700 | 10700/11080 |
Important Notes:
1. Nominal cooling capacity test conditions: water flow rate 0.172 m³/(h*kW), outlet water temperature 7°C, outdoor ambient temperature 35°C.
2. Nominal heating capacity test conditions: water flow rate 0.172 m³/(h*kW), outlet water temperature 45°C, outdoor dry/wet bulb temperature 7/6°C.
3. Total water pipe for modular combinations requires on-site fabrication and installation.
4. Modular units can be combined from 1 to 16 units using same or different models as needed.
5. Control accessories including remote controller, user manual, and connection cables must be ordered separately.
1. Nominal cooling capacity test conditions: water flow rate 0.172 m³/(h*kW), outlet water temperature 7°C, outdoor ambient temperature 35°C.
2. Nominal heating capacity test conditions: water flow rate 0.172 m³/(h*kW), outlet water temperature 45°C, outdoor dry/wet bulb temperature 7/6°C.
3. Total water pipe for modular combinations requires on-site fabrication and installation.
4. Modular units can be combined from 1 to 16 units using same or different models as needed.
5. Control accessories including remote controller, user manual, and connection cables must be ordered separately.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Beijing Holtop Artificial Environment Technology Co., Ltd
Location
No. 158, Hanjiachuan Village, Haidian District, Beijing, China
Contact Person
Nancy Yin