Holtop HFW-980HA1 Vortex Module-Type Air-Cooled Chilled Water (Heat Pump) Unit
The Holtop vortex module-type air-cooled chilled water (heat pump) unit utilizes advanced modular technology with air as the cooling/heating medium. This integrated central air conditioning equipment serves as both a cooling/heating source and combined unit, compatible with fan coil units, cabinet-type air handlers, ceiling-mounted units, and fresh air systems to form semi-centralized air conditioning solutions.
Key Features & Benefits
- Modular Design & Hierarchical Startup: Flexible module combination without main/secondary distinction. Supports up to 16 units per group with hierarchical startup to reduce current impact on power grids.
- Intelligent Defrosting: Multi-variable detection for precise frost timing. Dual-system design enables interval defrosting with manual override for harsh conditions.
- Flexible Application: Easy expansion for phased investment. Compact size enables independent transport and installation without special机房 or cooling water systems.
- Safe Operation Control: Comprehensive safety protection functions with intelligent multi-variable monitoring for efficient, stable performance.
- Fault Backup Operation: Dual-compressor design ensures continued operation if one compressor fails, maintaining system functionality.
Technical Specifications
Rated Voltage:Three-phase 380V/3N~
Rated Frequency:50Hz
Power Supply Voltage:±10% of rated voltage
Control Method:Remote controller
Fan Type:Axial flow low-noise fan
Storage Conditions:-28 to 85℃
Operating Range
| Operating Condition | Outdoor Ambient Temperature | Unit Outlet Water Temperature |
|---|---|---|
| Cooling | 15℃ ≤ Temperature ≤ 48℃ | 5℃ ≤ Temperature ≤ 15℃ |
| Heating | -15℃ ≤ Temperature ≤ 21℃ | 40℃ ≤ Temperature ≤ 50℃ |
Variable Operating Conditions - Refrigeration Systems
| Outlet Temperature (℃) | 25℃ Environment | 30℃ Environment | 35℃ Environment | 40℃ Environment | 45℃ Environment |
|---|---|---|---|---|---|
| 5 | 1.07 | 1.00 | 0.94 | 0.84 | 0.81 |
| 6 | 1.10 | 1.03 | 0.97 | 0.87 | 0.83 |
| 7 | 1.14 | 1.07 | 1.00 | 0.91 | 0.86 |
| 8 | 1.17 | 1.10 | 1.03 | 0.94 | 0.88 |
| 9 | 1.20 | 1.13 | 1.06 | 0.98 | 0.91 |
| 10 | 1.23 | 1.16 | 1.09 | 1.01 | 0.93 |
| 11 | 1.27 | 1.19 | 1.12 | 1.04 | 0.96 |
| 12 | 1.31 | 1.23 | 1.15 | 1.07 | 0.99 |
| 13 | 1.34 | 1.26 | 1.17 | 1.09 | 1.01 |
| 14 | 1.37 | 1.29 | 1.20 | 1.12 | 1.03 |
| 15 | 1.41 | 1.32 | 1.23 | 1.14 | 1.06 |
Variable Operating Conditions - Heating Mode
| Outlet Temperature (℃) | 15℃ Environment | 10℃ Environment | 7℃ Environment | 0℃ Environment | -5℃ Environment | -10℃ Environment |
|---|---|---|---|---|---|---|
| 30 | 1.23 | 1.10 | 1.03 | 0.94 | 0.88 | 0.75 |
| 35 | 1.21 | 1.09 | 1.02 | 0.93 | 0.87 | 0.75 |
| 40 | 1.20 | 1.08 | 1.01 | 0.91 | 0.85 | 0.74 |
| 45 | 1.19 | 1.07 | 1.00 | 0.90 | 0.84 | 0.74 |
| 50 | 1.17 | 1.05 | 0.98 | 0.85 | 0.80 | 0.74 |
Model Comparison - Large Vortex Modular Units
| Parameter | HFW-420HA1 | HFW-560HA1 | HFW-840HA1 | HFW-980HA1 | HFW-1120HA1 |
|---|---|---|---|---|---|
| Nominal Cooling Capacity (kW) | 420.0 | 560.0 | 840.0 | 980.0 | 1120.0 |
| Nominal Heating Capacity (kW) | 454.0 | 605.0 | 908.0 | 1059.0 | 1210.0 |
| Refrigeration Input Power (kW) | 129.2 | 172.3 | 258.4 | 301.5 | 344.6 |
| Heating Input Power (kW) | 132.4 | 176.4 | 264.8 | 308.8 | 352.8 |
| Compressor Quantity | 3 | 4 | 6 | 7 | 8 |
| Fan Power (kW) | 1.8x6 | 1.8x8 | 1.8x12 | 1.8x14 | 1.8x16 |
| Airflow (m³/h) | 23500x6 | 23500x8 | 23500x12 | 23500x14 | 23500x16 |
| Nominal Water Flow Rate (m³/h) | 72.2 | 96.3 | 144.4 | 168.5 | 192.6 |
| Water Resistance (kPa) | 65 | 65 | 65 | 65 | 65 |
| Pipe Connections | DN125 | DN125 | DN125*2 | DN125*2 | DN125*2 |
| Refrigerant Charge (kg) | 24.0x3 | 24.0x4 | 24.0x6 | 24.0x7 | 24.0x8 |
| Dimensions LxWxH (mm) | 3540x2280x2540 | 4700x2280x2540 | 7080x2280x2540 | 8240x2280x2540 | 9400x2280x2540 |
| Weight (kg) | 4020/4160 | 5350/5540 | 8040/8320 | 9370/9700 | 10700/11080 |
Important Notes:
1. Nominal cooling capacity test conditions: water flow rate 0.172 m³/(h*kW), outlet water temperature 7°C, outdoor ambient temperature 35°C.
2. Nominal heating capacity test conditions: water flow rate 0.172 m³/(h*kW), outlet water temperature 45°C, outdoor dry/wet bulb temperature 7/6°C.
3. Modular unit combination total water pipe requires on-site fabrication and installation.
4. Modular units can be combined from 1 to 16 units as needed. Above table shows single unit parameters.
5. Control accessories (remote controller, user manual, connection cables) must be ordered separately.
1. Nominal cooling capacity test conditions: water flow rate 0.172 m³/(h*kW), outlet water temperature 7°C, outdoor ambient temperature 35°C.
2. Nominal heating capacity test conditions: water flow rate 0.172 m³/(h*kW), outlet water temperature 45°C, outdoor dry/wet bulb temperature 7/6°C.
3. Modular unit combination total water pipe requires on-site fabrication and installation.
4. Modular units can be combined from 1 to 16 units as needed. Above table shows single unit parameters.
5. Control accessories (remote controller, user manual, connection cables) must be ordered separately.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Beijing Holtop Artificial Environment Technology Co., Ltd
Location
No. 158, Hanjiachuan Village, Haidian District, Beijing, China
Contact Person
Nancy Yin