High Dynamic Performance MEMS IMU with 1000Hz Output Data Rate and Full Temperature Compensation for Harsh Environments
The LKF-HH3001 High Dynamic Performance MEMS IMU features triaxial MEMS gyroscopes for angular motion detection and triaxial MEMS accelerometers for linear acceleration measurement. The system includes comprehensive temperature compensation for zero bias, scale factor, and inter-axis non-orthogonal errors, with software-adjustable internal low-pass cutoff frequency. These advanced features ensure sustained high measurement accuracy across the full operating temperature range of -40℃ to 85℃, even during rapid temperature changes (≤1℃/min).
With an output data rate (ODR) of 1000Hz and a measurement delay of only 7ms, the LKF-HH3001 delivers real-time motion data capture, making it ideal for high-dynamic application scenarios. The system supports flexible software configurations to meet diverse user requirements.
- 100% domestically sourced components
- High performance with compact size, lightweight design, and low power consumption
- Full temperature calibration compensation (-40°C to +85°C)
- High-speed sampling capabilities
- Resistance to harsh mechanical environments
- Supports firmware online updates
- Radar/infrared antenna stabilization platforms
- UAV attitude reference and flight path control
- Missile flight control systems
- Vehicle and ship attitude measurement
- Port measurement systems
- Satellite communication on-the-move
- Drilling and extraction systems
- Mobile mapping systems
- Automated driving test systems
| Gyroscope Specifications | |
| Range (°/s) | ±500 |
| Bias (°/h, full temperature) | 0.06 (1σ) |
| Bias Stability (°/h, 10s smoothing) | ≤5 |
| Bias Instability (°/h, allan) | 1.5 (@25℃, 1σ, IEEE standard) |
| Bias Repeatability (°/h) | ≤15 |
| Non-orthogonality | ≤0.02 deg |
| Angular Random Walk (°/√h) | 0.15 (@25℃, 1σ) |
| Scale Factor Nonlinearity (ppm) | ≤50 |
| Bandwidth (Hz) | 49 (internal low-pass cutoff, software adjustable) |
| Accelerometer Specifications | |
| Range (g) | ±60~±200 |
| Bias (mg, full temperature) | 0.7 (1σ) |
| Bias Stability (mg, 10s smoothing) | ≤0.06 |
| Bias Repeatability (mg) | ≤0.2 |
| Non-orthogonality | ≤0.02 deg |
| Scale Factor Nonlinearity (ppm, 1g) | ≤50 |
| Static Noise (mg) | 0.244 (Resolution) |
| Bandwidth (Hz) | 49 (internal low-pass cutoff, software adjustable) |
| Electrical/Mechanical Interface | |
| Power Supply (V) | 4.5~5.5 (Operating); -0.3~6.5 (Absolute Maximum) |
| Power Consumption (W) | 0.11 |
| Update Rate (Hz) | 1000Hz (customizable) |
| Operating Environment | |
| Operating Temperature (°C) | -40~85 |
| Storage Temperature (°C) | -40~85 |
| Vibration (g, RMS) | 10 (10~2KHz, 3-axis) |
| Shock (g) | 200g/6~8ms (Half-sine waveform, 2 tests) |