Upgrade Your Windows and Facades with Double Glazed Insulated Glass for Superior Thermal and Acoustic Performance
Double Glazed Insulated Glass (DGU) – Technical Specifications & Performance Guide
Double glazed insulated glass units (IGUs) are engineered assemblies consisting of two or more glass panes separated by a hermetically sealed spacer system, creating an insulating air or gas-filled cavity. This construction provides superior thermal and acoustic performance compared to monolithic glass.
Structural Composition & Configuration Options
-
Standard Construction
-
Glass: 2 panes (3-12mm each)
-
Spacer: Aluminum/Stainless Steel (6-20mm width)
-
Sealants: Primary (PIB) + Secondary (Silicone/Polysulfide)
-
Gas Fill: Argon (90%), Krypton (high-performance), or Air
-
-
Advanced Configurations
-
Triple Glazing: 3 panes + 2 cavities (U-value down to 0.4 W/m²K)
-
Asymmetrical: Different thicknesses (e.g., 6mm outer + 8mm inner)
-
Hybrid Units: Combined with Low-E coatings or laminated layers
-
Thermal Performance Metrics
Center-of-glass values for 4-12-4 configuration
Acoustic Performance Data
-
Sound Transmission Class (STC)
-
4mm/12mm Air/4mm: STC 32
-
6mm/16mm Argon/6mm: STC 36
-
Laminated Variant: STC 42+
-
-
Frequency-Specific Attenuation
-
500Hz: 25-35dB reduction
-
1000Hz: 30-40dB reduction
-
2000Hz: 35-45dB reduction
-
Spacer Technology Comparison
Gas Fill Performance
Manufacturing Standards
-
Quality Control
-
Moisture vapor transmission <0.05g/m²/day
-
Gas retention >90% after 15 years
-
Sealant adhesion >0.5N/mm²
-
-
Certifications
-
EN 1279 (European IGU standard)
-
ASTM E2190 (North America)
-
GB/T 11944 (China)
-
ISO 20492 (Global performance)
-
Installation Requirements
-
Glazing Systems
-
Minimum 15mm edge cover
-
Thermal break framing recommended
-
Structural silicone bonding options
-
-
Environmental Limits
-
Maximum altitude: 3000m
-
Temperature range: -40°C to +80°C
-
Pressure differential: ±3000Pa
-
Durability Testing Protocols
-
Climate Resistance
-
1000 cycles (-20°C to +60°C)
-
5000hr humidity exposure (85°C/85%RH)
-
UV aging per ISO 4892-3
-
-
Structural Testing
-
Wind load resistance (EN 12179)
-
Water penetration (ASTM E331)
-
Air infiltration (ASTM E283)
-
Leading Manufacturers
-
Guardian Glass (ClimaGuard®)
-
U-value as low as 0.5
-
25-year performance warranty
-
-
Saint-Gobain (SGG ClimaPlus®)
-
Warm edge spacer systems
-
PHI-certified options
-
-
AGC (EnergyNXT™)
-
Triple silver Low-E variants
-
Self-cleaning IGU options
-
-
NSG (Pilkington Insulight™)
-
Krypton-filled units
-
Acoustic-specific designs
-
Sustainability Features
-
30% recycled glass content
-
Argon from air separation byproducts
-
Warm edge spacers reduce edge losses
-
Contributes to LEED v4.1 credits:
-
Thermal Performance (EQ)
-
Daylight Optimization (EQ)
-
Failure Modes & Prevention
-
Gas Loss
-
Cause: Seal failure
-
Prevention: Dual-seal systems
-
-
Condensation
-
Cause: Desiccant saturation
-
Prevention: Molecular sieve quality control
-
-
Glass Breakage
-
Cause: Thermal stress
-
Prevention: Edge deletion for coated glass
-
Technical Support Services
-
Performance Modeling
-
THERM/WINDOW simulations
-
Condensation risk analysis
-
-
Custom Engineering
-
Curved IGUs (R>1000mm)
-
Structural glazing solutions
-
-
Quality Verification
-
Gas concentration testing
-
Sealant adhesion checks
-
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.