Upgrade Your Windows and Facades with Double Glazed Insulated Glass for Superior Thermal and Acoustic Performance

Price Negotiable
Price: Negotiable
MOQ: 1M2
Delivery Time: 14days
Brand: YIWO GLASS
Product Description

​Double Glazed Insulated Glass (DGU) – Technical Specifications & Performance Guide​

Double glazed insulated glass units (IGUs) are engineered assemblies consisting of two or more glass panes separated by a hermetically sealed spacer system, creating an insulating air or gas-filled cavity. This construction provides superior thermal and acoustic performance compared to monolithic glass.


​Structural Composition & Configuration Options​

  1. ​Standard Construction​

    • ​Glass:​​ 2 panes (3-12mm each)

    • ​Spacer:​​ Aluminum/Stainless Steel (6-20mm width)

    • ​Sealants:​​ Primary (PIB) + Secondary (Silicone/Polysulfide)

    • ​Gas Fill:​​ Argon (90%), Krypton (high-performance), or Air

  2. ​Advanced Configurations​

    • ​Triple Glazing:​​ 3 panes + 2 cavities (U-value down to 0.4 W/m²K)

    • ​Asymmetrical:​​ Different thicknesses (e.g., 6mm outer + 8mm inner)

    • ​Hybrid Units:​​ Combined with Low-E coatings or laminated layers


​Thermal Performance Metrics​

​Parameter​

​Standard DGU​

​Low-E DGU​

​Premium DGU​

​U-value (W/m²K)​ 2.6-2.8 1.1-1.6 0.5-1.0
​SHGC​ 0.70-0.80 0.25-0.50 0.15-0.30
​Light Transmission​ 75-85% 40-70% 30-60%
​Condensation Risk​ -20°C -40°C -60°C

Center-of-glass values for 4-12-4 configuration


​Acoustic Performance Data​

  1. ​Sound Transmission Class (STC)​

    • ​4mm/12mm Air/4mm:​​ STC 32

    • ​6mm/16mm Argon/6mm:​​ STC 36

    • ​Laminated Variant:​​ STC 42+

  2. ​Frequency-Specific Attenuation​

    • ​500Hz:​​ 25-35dB reduction

    • ​1000Hz:​​ 30-40dB reduction

    • ​2000Hz:​​ 35-45dB reduction


​Spacer Technology Comparison​

​Type​

​Thermal Break​

​Dew Point​

​Linear Transmittance​

​Aluminum​ None -20°C 0.35 W/mK
​Warm Edge (TPS)​ Excellent -60°C 0.07 W/mK
​Stainless Steel​ Moderate -40°C 0.12 W/mK
​Hybrid (Foam/Metal)​ Good -50°C 0.09 W/mK

​Gas Fill Performance​

​Gas​

​Thermal Conductivity (W/mK)​

​Cost Factor​

​Optimal Cavity Width​

Air 0.024 1.0x 12-16mm
Argon 0.016 1.2x 12-18mm
Krypton 0.009 6.0x 6-12mm
Xenon 0.005 20.0x 4-8mm

​Manufacturing Standards​

  1. ​Quality Control​

    • Moisture vapor transmission <0.05g/m²/day

    • Gas retention >90% after 15 years

    • Sealant adhesion >0.5N/mm²

  2. ​Certifications​

    • EN 1279 (European IGU standard)

    • ASTM E2190 (North America)

    • GB/T 11944 (China)

    • ISO 20492 (Global performance)


​Installation Requirements​

  1. ​Glazing Systems​

    • Minimum 15mm edge cover

    • Thermal break framing recommended

    • Structural silicone bonding options

  2. ​Environmental Limits​

    • Maximum altitude: 3000m

    • Temperature range: -40°C to +80°C

    • Pressure differential: ±3000Pa


​Durability Testing Protocols​

  1. ​Climate Resistance​

    • 1000 cycles (-20°C to +60°C)

    • 5000hr humidity exposure (85°C/85%RH)

    • UV aging per ISO 4892-3

  2. ​Structural Testing​

    • Wind load resistance (EN 12179)

    • Water penetration (ASTM E331)

    • Air infiltration (ASTM E283)


​Leading Manufacturers​

  1. ​Guardian Glass (ClimaGuard®)​

    • U-value as low as 0.5

    • 25-year performance warranty

  2. ​Saint-Gobain (SGG ClimaPlus®)​

    • Warm edge spacer systems

    • PHI-certified options

  3. ​AGC (EnergyNXT™)​

    • Triple silver Low-E variants

    • Self-cleaning IGU options

  4. ​NSG (Pilkington Insulight™)​

    • Krypton-filled units

    • Acoustic-specific designs


​Sustainability Features​

  • 30% recycled glass content

  • Argon from air separation byproducts

  • Warm edge spacers reduce edge losses

  • Contributes to LEED v4.1 credits:

    • Thermal Performance (EQ)

    • Daylight Optimization (EQ)


​Failure Modes & Prevention​

  1. ​Gas Loss​

    • Cause: Seal failure

    • Prevention: Dual-seal systems

  2. ​Condensation​

    • Cause: Desiccant saturation

    • Prevention: Molecular sieve quality control

  3. ​Glass Breakage​

    • Cause: Thermal stress

    • Prevention: Edge deletion for coated glass


​Technical Support Services​

  1. ​Performance Modeling​

    • THERM/WINDOW simulations

    • Condensation risk analysis

  2. ​Custom Engineering​

    • Curved IGUs (R>1000mm)

    • Structural glazing solutions

  3. ​Quality Verification​

    • Gas concentration testing

    • Sealant adhesion checks


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company QINHUANGDAO YIWO GLASS CO.,LTD
Location NO.6 TIANTAISHAN ROAD,ECONOMIC&TECHNICAL DEVELOPMENT ZONE,QINHUANGDAO,HEBEI
Contact Person Mrs.

Request A Quote

Please check your email address.
Your message must be at least 20 characters.