EVF9324-EVV004 Lenze 9300 Vector Drive 7.5kW 400V Original
Price:
$878
MOQ:
1
Delivery Time:
3-5 days
Brand:
Lenze
Product Description
Product pictures

Product Overview: Lenze EVF9324-EVV004 (9300 Vector)
| Parameter | Specification |
|---|---|
| Manufacturer | Lenze |
| Order Code | EVF9324-EVV004 |
| Product Series | 9300 Vector |
| Device Type | High-Performance Vector / Servo AC Drive |
Application & Fault Scenarios
Typical Uses: Packaging machine axis control, printing press registration, textile winder tension regulation.
Common Field Issues:
Note: Firmware version must match application library; mismatched FW causes parameter set incompatibility during commissioning.
Related products
| EVF9322-EVV004 | EVF9325-EVV004 |
| EVF9326-EVV004 | EVF9327-EVV004 |
| EVF9324-EVAV04 | EVF9324-EVPV04 |
| EVF9324-EVI004 | EVF9324-EVE004 |
| ECS9322-EVV004 | ECS9324-EVV004 |
| EVD9324-EVV004 | EVF8224-EVV004 |
| EMZ9371BC Keypad | AIF-CANOPEN Module |
| ERBD016R0 Brake Resistor | EL9410 Power Supply |
| EVF9324-EVV010 | EVF9324-EVV020 |
FAQ
Q1: What does “EVV004” suffix mean in Lenze EVF9324-EVV004?
A: “EVV” denotes standard 9300 Vector hardware platform; “004” specifies integrated CANopen + basic I/O configuration; other suffixes like “EVPV04” indicate PROFIBUS or “EVE004” EtherCAT variants.
A: “EVV” denotes standard 9300 Vector hardware platform; “004” specifies integrated CANopen + basic I/O configuration; other suffixes like “EVPV04” indicate PROFIBUS or “EVE004” EtherCAT variants.
Q2: Can EVF9324-EVV004 run synchronous servo motors?
A: Yes — supports permanent magnet synchronous motors in servo mode with resolver or TTL/HTL encoder feedback; configure motor type via Lenze Engineer parameter set.
A: Yes — supports permanent magnet synchronous motors in servo mode with resolver or TTL/HTL encoder feedback; configure motor type via Lenze Engineer parameter set.
Q3: Is this drive compatible with legacy Lenze 8200 series parameters?
A: Partially — use migration table in GDC software to convert key parameters, but advanced functions require reprogramming due to architecture differences between 8200 and 9300 platforms.
A: Partially — use migration table in GDC software to convert key parameters, but advanced functions require reprogramming due to architecture differences between 8200 and 9300 platforms.