1SDA073725R1 ABB Spring Charging Motor (M) for Emax 2 Air Circuit Breakers E2.2…E6.2, 220-250V AC/DC
Price:
$220
MOQ:
1
Delivery Time:
3-5 days
Brand:
ABB
Product Description
Product pictures

Product Overview: ABB 1SDA073725R1
| Parameter | Specification |
|---|---|
| Manufacturer | ABB |
| Order Number | 1SDA073725R1 |
| Product Type | Spring Charging Motor (M) for air circuit breaker mechanism |
| Application | Charges the closing springs of ABB Emax 2 low-voltage ACB after each closing operation, enabling automatic re-close readiness |
Application & Fault Scenarios
Related products
| 1SDA073711R1 | 1SDA073724R1 |
| 1SDA073726R1 | 1SDA038324R1 |
| 1SDA073712R1 | 1SDA073730R1 |
| 1SDA073713R1 | 1SDA073731R1 |
| 1SDA073714R1 | 1SDA073732R1 |
| 1SDA073740R1 | 1SDA073741R1 |
| 1SDA073742R1 | 1SDA073743R1 |
| 1SDA073750R1 | 1SDA073751R1 |
| 1SDA073752R1 | 1SDA073753R1 |
| 1SDA062162R1 | 1SDA073917R1 |
FAQ
Q1: What is ABB 1SDA073725R1?
A: It is the spring charging motor (M) for ABB Emax 2 low-voltage air circuit breakers, frames E2.2 to E6.2, rated 220-250V AC/DC. It automatically re-charges the closing springs after each operation.
A: It is the spring charging motor (M) for ABB Emax 2 low-voltage air circuit breakers, frames E2.2 to E6.2, rated 220-250V AC/DC. It automatically re-charges the closing springs after each operation.
Q2: Which breakers is 1SDA073725R1 compatible with?
A: Emax 2 frames E2.2, E4.2 and E6.2. It does not fit E1.2 (use 1SDA073711R1) and is not compatible with Tmax XT MCCBs or VD4 medium-voltage breakers. Verify the nameplate voltage before fitting.
A: Emax 2 frames E2.2, E4.2 and E6.2. It does not fit E1.2 (use 1SDA073711R1) and is not compatible with Tmax XT MCCBs or VD4 medium-voltage breakers. Verify the nameplate voltage before fitting.
Q3: Symptoms of a failed charging motor?
A: "Springs not charged" indication, breaker refuses to close, no sound when control power is applied, burning smell, or motor running continuously without stopping. In the last case, isolate power immediately and check the mechanism linkage.
A: "Springs not charged" indication, breaker refuses to close, no sound when control power is applied, burning smell, or motor running continuously without stopping. In the last case, isolate power immediately and check the mechanism linkage.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Xiamen Changxuyuan Trading Co., Ltd
Location
Room 202-5, Building 21, Wanghai Road, Software Park 2, Huli District, Xiamen, Fujian China 361008
Contact Person
Robin