SF6 Free High Voltage Switchgear 12kv Solid Insulated Switchgear For Indoor
Price:
$2000
MOQ:
1
Delivery Time:
20 days
Brand:
MKS-12
Product Description
High Voltage Switchgear 12kv Solid Insulated Ring Main Unit RMU For Indoor with SF6 free
Since the 1990s, with accelerating urbanization and continual improvement of power supply reliability, overhead lines have been replaced by buried cables and indoor switching stations by outdoor switching stations. The small, touchable, all-insulated, flood-control, and maintenance-free ring main units have rapidly developed and are widely used in various locations requiring reliable power distribution systems, including urban commercial centers, industrial districts, airports, electrified railways, and expressways. These units can be used singly indoors or outdoors, as well as integrated into prefabricated substations.
The MKS series solid-insulated ring main units incorporate advanced production facilities and manufacturing technology, enabling localized production that significantly reduces manufacturing costs and shortens delivery periods. This product line has received favorable responses since its launch.
Key Specifications
- Product Model: MKS-12
- Rated Specification: 12 kV - 630 A
- Core Unit Configuration: Upper-isolation / Lower-isolation
- Altitude Classifications: ≤ 1500 m / > 1500 m
- Operation Mode: Manual / Electric
- Rated Short-circuit Breaking Current: 20 kA / 25 kA
- Integral Earthing Switch: With / Without
- Control Voltage: 24 V / 48 V / 220 V (110 V on request)
- Standard Configuration: Vacuum circuit-breaker / load-break switch, three-position disconnector
Technical Specifications
| Item | Unit | load switch cell | circuit breaker cell | Fuse Combining cell |
|---|---|---|---|---|
| Rated voltage | kV | 12 | 12 | 12 |
| Rated current | A | 630 | 630 | depend on the fuse |
| Rated frequency | Hz | 50 | 50 | 50 |
| 1 min power frequency withstand voltage (phase to phase & phase to ground) | kV | 42 | 42 | 42 |
| 1min Power Frequency Withstand Voltage (Isolation Gap) | kV | 48 | 48 | 48 |
| RatedPower Frequency Withstand Voltage(Control &Auxiliary Circuits) | kV | 2 | 2 | 2 |
| Lightning Impulse Withstand Voltage(Phase-to-Phase &Phase-to-Ground) | kV | 75 | 75 | 75 |
| Lightning Impulse Withstand Voltage (Isolation Gap) | kV | 85 | 85 | 85 |
| Short-Circuit Breaking Current | kA | 20 | 20 | depend on the fuse |
| Rated Short-Circuit Making Current | kA | 50 | 50 | depend on the fuse |
| Rated Short-Time Withstand Current | kA | 20 | 20 | / |
| Rated Short-Time Duration | s | 4 | 4 | / |
| Rated Peak Withstand Current | kA | 50 | 50 | / |
| Rated transfer current | A | / | / | 3150 |
| Rated Operating sequence | / | O-0.3s-CO-180s-CO | / | / |
| Mechanical life | times | 10000 | 10000 | 10000 |
| Disconnector/grounding switch | times | 3000 | 3000 | 3000 |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Ningbo Macwey Industrial Technology Co.,Ltd
Location
No.218, Weier Road, Chongshou Industrial Park, Cixi City (Ningbo), China
Contact Person
Alec Sung