GE Fanuc IS215UCVDH5A Mark VI SPEEDTRONIC PLC Controller with 256 MB DDR ECC RAM and -40°C to +70°C Operating Range
Price:
$10-3000
MOQ:
1 piece
Delivery Time:
3-5 work days
Brand:
General Electric
Product Description
GE Fanuc IS215UCVDH5A Controller - A factory-tested VME-based controller from GE's Mark VI SPEEDTRONIC™ family, engineered for precise gas- and steam-turbine control, protection, and sequencing. Drop-in replacement for legacy IS215UCV* cards—guaranteed 100% authentic, firmware unaltered, ready for immediate field deployment.
Key Features & Benefits
OEM Genuine GE Fanuc part - serialized & sealed ESD bag
VME64x-compliant 6U single-slot card
64-bit RISC processor with 256 MB DDR ECC RAM
Dual 10/100 Ethernet ports for HMI & ToolboxST™ connectivity
512 MB on-board flash for application & historical data logging
Redundant power feeds (5V / 3.3V) with hot-swap support
Wide operating temperature range: -40°C to +70°C (conformal coated)
SIL 2 capable per IEC 61508 for safety-critical loops
Compatible with Mark VI Simplex & TMR (Triple Modular Redundant) racks
Technical Specifications
| Parameter | Value |
|---|---|
| Part Number | IS215UCVDH5A |
| Series | Mark VI SPEEDTRONIC |
| Form Factor | 6U VME64x, single-slot |
| Processor | 64-bit PowerPC @ 333 MHz |
| Memory | 256 MB DDR ECC, 512 MB Flash |
| Communication | 2× 10/100 Base-TX (RJ-45), 1× RS-232 (DIAG), VME P1/P2 |
| I/O Scan Rate | < 5 ms (typical) |
| Power | +5V @ 6A, +3.3V @ 3A |
| Operating Temperature | -40°C to +70°C |
| Humidity | 5% to 95% RH non-condensing |
| Shock/Vibration | 15g / 2g per IEC 60068-2-27/-64 |
| Approvals | CE, UL, CSA, ATEX Zone 2, SIL 2 |
Typical Applications
Gas & steam turbine control (Frame 5/6/7/9)
Generator excitation & synchronization
Compressor anti-surge & load-sharing control
Emergency trip & protection systems (ETS)
Retrofit upgrades for Mark V / Mark IV panels
Package Contents
1× IS215UCVDH5A controller module
1× Factory calibration & traceability certificate
1× ESD wrist strap
Quick-install guide & slot keying chart
Installation & Setup Guide
1. Power down the Mark VI rack; follow ESD procedures.
2. Insert the card into the designated VME slot (refer to R, S, T rack map).
3. Apply torque to front-panel screws (12 in-lb / 1.4 N*m).
4. Power up and verify green STATUS LED (< 30 s).
5. Connect ToolboxST™ via Ethernet; upload latest application file (*.m6b).
6. Perform loop test and trip-check per OEM start-up sequence.