Schneider Electric LSS100300 SpaceLogic KNX BMS IP Gateway Original New
Price:
Negotiable
MOQ:
Negotiable
Delivery Time:
Negotiable
Product Description
Product Overview
The Schneider Electric LSS100300 is a dedicated BACnet/IP Gateway designed specifically for integrating KNX building automation systems with Building Management Systems (BMS). Unlike the LSS100100 and LSS100200 logic controllers, the LSS100300 serves as a protocol converter, enabling bidirectional communication between KNX installations and BACnet-based BMS platforms like EcoStruxure Building Operation.
Technical Specifications
General Information
| Parameter | Specification |
|---|---|
| Product Name | SpaceLogic KNX BMS IP Gateway |
| Product Code | LSS100300 |
| Product Type | Protocol Gateway / Router |
| Function | KNX to BACnet/IP protocol conversion |
| Protection Rating | IP20 |
| Mounting | DIN rail |
| Origin | Latvia (LV) |
| RoHS Compliant | Yes |
Electrical Parameters
| Parameter | Specification |
|---|---|
| Supply Voltage | 24 V DC |
| Power Consumption | 2 W (standby) / 12 W (max) |
| Status Indicators | CPU load (green LED), KNX power/reset (green/red LED) |
Communication Interfaces
| Interface | Specification |
|---|---|
| KNX | KNX TP (Twisted Pair) - bus terminal |
| Ethernet | 1* RJ45 (BACnet/IP) |
| Protocols | KNX TP, BACnet/IP |
Physical Specifications
| Parameter | Specification |
|---|---|
| Mounting | DIN rail mount |
| Installation | Standard electrical panel |
Environmental Conditions
| Parameter | Specification |
|---|---|
| Operating Temperature | Standard industrial range |
| Humidity | Non-condensing |
Key Features
Bidirectional Protocol Gateway
- KNX to BACnet/IP conversion: Seamlessly integrates KNX devices into BACnet-based BMS
- Bidirectional communication: Read and write operations between both protocols
- Multi-device support: Connects entire KNX installations to BMS platforms
BMS Integration
- EcoStruxure Building Operation: Native compatibility with Schneider Electric BMS
- Third-party BMS support: Works with any BACnet/IP-compliant building management system
- Simplified commissioning: Reduces integration complexity for mixed-protocol environments
Core Functions
- Protocol translation: Automatic conversion of KNX data points to BACnet objects
- Data mapping: Flexible configuration of KNX group addresses to BACnet properties
- Real-time monitoring: Live status updates between KNX field devices and BMS
- Control operations: BMS can send commands to KNX actuators through the gateway
Network Services
- KNX IP routing: Functions as KNXnet/IP router
- BACnet B-BC profile: BACnet Building Controller certification
- Ethernet connectivity: Standard RJ45 connection to IP networks
LSS100300 vs LSS100100/LSS100200 Comparison
| Feature | LSS100100 (Wiser for KNX) | LSS100200 (spaceLYnk) | LSS100300 (BMS Gateway) |
|---|---|---|---|
| Primary Function | Logic Controller | Logic Controller | Protocol Gateway |
| Target Use | Residential / Small commercial | Commercial buildings | BMS Integration |
| BACnet Role | Server (150 points) | Server (2,000 points) | Gateway/Translator |
| Web SCADA | Yes | Yes | No (BMS handles visualization) |
| Logic Programming | Yes | Yes | No (pass-through device) |
| Modbus Support | Yes | Yes (31 devices) | Via BMS |
| KNX Interface | TP-UART2 | TP1 | TP (dedicated) |
| Best For | Standalone control | Large building control | KNX-BMS integration |
Typical Applications
Commercial Building Integration
- Office building KNX lighting integration with central BMS
- HVAC system coordination between KNX sensors and BACnet controllers
- Energy management system (EMS) integration
Hospitality BMS Projects
- Hotel room KNX controls connected to property management systems
- Centralized monitoring of guest room status
- Integration with building-wide energy optimization
Healthcare Facilities
- KNX lighting and blinds integration with hospital BMS
- Nurse call system integration
- Compliance monitoring and reporting
Educational Campuses
- Multi-building KNX integration into campus-wide BMS
- Centralized scheduling and control
- Energy dashboard integration
Retrofit Projects
- Adding KNX zones to existing BACnet-based buildings
- Phased upgrades without replacing entire BMS
- Mixed protocol environments
Why Choose LSS100300?
| Advantage | Benefit |
|---|---|
| Dedicated Gateway | Optimized for protocol conversion, not general control |
| BMS Native | Designed specifically for EcoStruxure and BACnet BMS |
| Simplified Architecture | No programming required, configuration only |
| Reliable Bridging | Purpose-built for 24/7 KNX-BMS communication |
| Cost Effective | Lower cost than full logic controller for gateway-only needs |
| Scalable | One gateway handles entire KNX installation |
System Architecture Example
┌─────────────────┐ ┌─────────────┐ ┌─────────────────┐
│ KNX Devices │◄───────►│ LSS100300 │◄───────►│ BMS Platform │
│ (Sensors, │ KNX TP │ Gateway │Ethernet │ (EcoStruxure/ │
│ Actuators) │ │ │ BACnet/IP Third-party) │
└─────────────────┘ └─────────────┘ └─────────────────┘
Ordering Information
| Item | Details |
|---|---|
| Product Code | LSS100300 |
| EAN/GTIN | 3606482215856 |
| Minimum Order | 1 piece |
| Package Contents | Gateway device with installation manual |
Note: Check regional availability with your Schneider Electric distributor.
Related Products
- LSS100100 (Wiser for KNX) - Logic controller for residential
- LSS100200 (spaceLYnk) - Logic controller for commercial
- EcoStruxure Building Operation - BMS platform
- KNX Power Supplies - For KNX bus powering
- KNX Sensors & Actuators - Field devices
When to Use LSS100300 vs Logic Controllers
Choose LSS100300 when:
- You have an existing or planned BACnet BMS
- You need to integrate KNX devices into a central management platform
- You don't need local logic programming
- The BMS will handle visualization and control logic
Choose LSS100100/LSS100200 when:
- You need standalone control without a BMS
- You want built-in Web SCADA visualization
- You need local logic programming and scheduling
- You're building a smaller system without central BMS
Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Guangzhou Hengmeida Automation Technology Co., Ltd
Location
Building B, Letian Zhigu (Smart Valley), Guanzhou Street, Haizhu District, Guangzhou, China
Contact Person
Lueng