24V High Lift Electric Coolant Pump 6 Bar for DC Fast Charging Gun Cooling
Product Features

The OWP-BL60H is a brushless motor driven electric water pump with PWM signal speed regulation, designed to drive coolant flow in cooling circuits. It operates continuously or intermittently and features self-diagnosis and fault feedback functions.

Scope of Use
  • Primarily used in server cooling, fixed base station cooling, and charging terminal cooling
  • Compatible with antifreeze (maximum 60% glycol)
Basic Parameters
No. Item Parameter
1 Rated voltage DC24V
2 Operating voltage DC16~32V
3 Ingress protection IP67
4 Weight 650g
5 Rated power 60W
6 Life span ≥20000h
7 Noise ≤45dB
8 Rated parameters When flow Q=2L/min, H≥30m
9 Pump withstands system pressure -99kPa~600kPa
10 Medium temperature range -40℃~85℃
11 Operating ambient temperature -40℃~70℃
12 Operating humidity range Relative humidity 5%~95%
13 Storage temperature and humidity -40℃~70℃, Relative humidity 5%~95%
Function Description
  • Reverse connection protection: Pump won't start with reversed polarity and resumes normal operation when corrected.
  • Dry-running protection: Automatically stops when water runs dry and resumes normal operation when water is restored.
  • Stall protection: Automatically stops when waterway is blocked and resumes when circulation is restored.
  • Over current protection: Reduces speed until stopping when protection current is exceeded.
  • Under-voltage/over-voltage protection: Reduces speed until stopping when operating voltage is exceeded.
Note: Mechanical switches should not be used to directly control the motor. Never operate the pump without water.
Pump Performance Curve
Performance curve graph of the 24V High Lift Electric Coolant Pump
Product Connector & Speed Regulation

Harness terminal description: Water pump connector model: Hirschmann805-121-522

Terminal number Description
1 +24VDC
2 Communication interface
3 GND

Pump Operation Control:

Input PWM signal (high level active) requirements:

  • Effective High Level: 14~32V
  • Effective low level: 0~6V
  • Duty cycle adjustment range: 0~100%
  • Frequency: 50Hz~1000Hz (100Hz recommended)

PWM Control Schematic Diagram:

PWM control schematic diagram for the 24V High Lift Electric Coolant Pump
No. Duty-cycle Description Remark
1 0-5% Max speed Not recommend use
2 6-8% Max speed Open-circuit signal
3 8-13% 0 rpm(stop) Recommended 10% as stop signal
4 13%-17% Min speed Running at Min speed
5 17%-85% Linear speed control Min-Max speed
6 85%-95% Max speed Recommended 90% as full speed
7 95%-100% Max speed Not recommend use
Recommended Installation Methods

Installation Position:

  • Mount on fixed bracket of the device
  • Consider vibration and noise requirements in installation location and fastener design
  • Avoid water accumulation on or inside the connector
  • Secure connector properly to prevent damage from wiring harness vibration

Bracket Requirements:

  • Design must consider vibration and noise requirements
  • Secure wiring harness to prevent movement relative to pump connector
  • No other parts allowed to be fixed on the pump
Overall Size
Overall size diagram of the 24V High Lift Electric Coolant Pump Additional size diagram of the 24V High Lift Electric Coolant Pump

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Changzhou Bextreme Shell Motor Technology Co.,Ltd
Location No.91 Hanjiang Rd, Changzhou, Jiangsu,China
Contact Person Eric Peng

Request A Quote

Please check your email address.
Your message must be at least 20 characters.