Inverter ACS880 low-voltage AC industrial frequency converter 0.55-250kW
ACS880 Low-Voltage AC Industrial Frequency Converter
The ACS880 is a comprehensive low-voltage AC industrial frequency converter covering a power range of 0.55-6000kW and voltage range of 230-690V. Featuring enhanced Direct Torque Control (DTC) technology, built-in safety functions, and multi-communication adaptability, this drive is engineered for harsh industrial environments across various sectors and offers flexible compatibility with multiple motor types.
Product Highlights
- Power range: 0.55 to 250kW
- Built on ABB's standard drive architecture
- Protection classes: IP20, IP21, and IP55
- Direct Torque Control (DTC) as standard
- Comprehensive safety functions including Safe Torque Off (STO)
- Intuitive control panel with USB interface
- Built-in EMC filter, reactor, and brake chopper
- Supports wide range of fieldbus protocols, I/O, and encoder options
- Flexible I/O and encoder options
- Certified marine design
Core Specifications
| Parameter Category | Specifications |
|---|---|
| Power Range | 0.55-250 kW |
| Input Voltage | 3-phase 380-480 V AC (Standard), 3-phase 500-690 V AC (Optional) |
| Input Frequency | 50/60 Hz ±5% |
| Output Voltage | 0-Input Voltage (Continuously Adjustable) |
| Output Frequency | 0-500 Hz |
| Control Method | Direct Torque Control (DTC), V/F Control (Optional) |
| Protection Class | IP20, IP21, IP55 |
| Safety Functions | Safe Torque Off (STO), Safe Stop 1 (SS1, Optional), Safe Limited Speed (SLS, Optional) |
| Built-in Components | EMC Filter (Class C2), Input Reactor, Brake Chopper |
| Communication Protocols | Supports Profinet, Modbus RTU, EtherNet/IP, DeviceNet, CANopen, etc. |
| I/O Interfaces | Digital Inputs: 6 channels (Configurable); Digital Outputs: 2 channels (Configurable); Analog Inputs: 2 channels; Analog Outputs: 2 channels |
| Encoder Support | Incremental Encoder, Absolute Encoder (Optional) |
| Ambient Temperature | -10°C to +40°C (No Derating), +40°C to +50°C (Derated Operation) |
| Cooling Method | Self-cooling (Standard), Forced Air Cooling (Optional for High-power Models) |
| Certifications | CE, UL, cUL, DNV GL (Marine), ATEX (Explosion-proof, Optional) |
Model Series Overview
| Model Series | Power Range | Input Voltage | Protection Class | Mounting Type | Key Configuration | Applicable Regions/Scenarios |
|---|---|---|---|---|---|---|
| ACS880-01-0010-3 | 0.55 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter | Global (except North America), for small pumps/fans |
| ACS880-01-0016-3 | 1.1 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter | Global (except North America), small machining equipment |
| ACS880-01-0025-3 | 1.5 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter | Global (except North America), conveyors, rolling doors |
| ACS880-01-0040-3 | 2.2 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter | Global (except North America), small compressors |
| ACS880-01-0060-3 | 4 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Brake Chopper | Global (except North America), printing machinery |
| ACS880-01-0085-3 | 5.5 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Brake Chopper | Global (except North America), packaging equipment |
| ACS880-01-0120-3 | 7.5 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Brake Chopper | Global (except North America), fans, water pumps |
| ACS880-01-0160-3 | 11 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Input Reactor | Global (except North America), injection molding machine auxiliary equipment |
| ACS880-01-0200-3 | 15 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Input Reactor | Global (except North America), textile machinery |
| ACS880-01-0250-3 | 18.5 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Input Reactor | Global (except North America), crane hoisting mechanisms |
| ACS880-01-0320-3 | 22 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Brake Chopper | Global (except North America), air compressors |
| ACS880-01-0400-3 | 30 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Input Reactor | Global (except North America), machine tool spindles |
| ACS880-01-0500-3 | 37 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Brake Chopper | Global (except North America), central air conditioning chillers |
| ACS880-01-0630-3 | 45 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Input Reactor | Global (except North America), material handling equipment |
| ACS880-01-0800-3 | 55 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Brake Chopper | Global (except North America), mine ventilators |
| ACS880-01-1000-3 | 75 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Input Reactor | Global (except North America), port cranes |
| ACS880-01-1250-3 | 90 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Brake Chopper | Global (except North America), cement rotary kilns |
| ACS880-01-1600-3 | 110 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Input Reactor | Global (except North America), paper machines |
| ACS880-01-2000-3 | 132 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Brake Chopper | Global (except North America), steel mill roller tables |
| ACS880-01-2500-3 | 160 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Input Reactor | Global (except North America), chemical mixers |
| ACS880-01-3150-3 | 200 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Brake Chopper | Global (except North America), wind turbine yaw systems |
| ACS880-01-4000-3 | 250 kW | 3-phase 380-480 V AC | IP20 | Wall-mounted | DTC Control, STO Safety Function, Built-in EMC Filter + Input Reactor | Global (except North America), large pumps/fans |
Industry Application Scenarios
| Industry Sector | Practical Application Scenarios | Core Needs & Drive Adaptability |
|---|---|---|
| General Machinery Manufacturing (Europe/Middle East) | Small processing machines (lathes, milling machines), packaging equipment (labeling machines, film sealers), conveyor production lines | Voltage compatibility with European standards (380-480V/500-690V) and IP20/IP21 protection for workshop dust environments; DTC control for precise speed regulation, adapting to frequent start/stop of machinery; Built-in EMC filter compliant with CE electromagnetic compatibility standards |
| HVAC (North America) | Central air conditioning chillers in commercial buildings, ventilation fans in malls/factories, hot water circulation pumps in hotels | North American voltage standard (208-240V) + UL certification for compliant market access; Wide frequency range (0-500Hz) for variable flow regulation of fans/pumps; Intuitive control panel for on-site debugging with USB interface for parameter backup |
| Marine & Shipping (Global) | Ship deck windlasses/winches, cabin ventilation fans, seawater desalination pumps, marine auxiliary machinery drives | DNV GL marine certification, withstanding high salt spray and vibration; STO safety function to prevent accidental equipment startup; Compact design suitable for limited installation space with IP55 protection against seawater splashing |
| Water Treatment & Supply (Southeast Asia/Africa) | Municipal sewage treatment aeration fans, waterworks booster pumps, agricultural irrigation pumps | Wide input voltage range (380-480V) adapting to unstable local power grids; IP55 dustproof and waterproof design for outdoor open-air installation; Built-in brake chopper to handle pump start/stop impacts and extend equipment lifespan |
| Food & Beverage Processing (Europe) | Production line conveyors, mixers, homogenizers, cleaning equipment (bottle washers, sterilizers) | IP21 splash-proof design for humid workshop environments with frequent cleaning; Sensorless DTC control eliminating the need for encoders, reducing hygiene dead corners; Quick start/stop function adapting to production line batch change requirements |
Market Considerations
- Regional Compliance Priority: North American markets require UL certification + 208-240V voltage; European markets emphasize CE/ATEX certification + 500-690V high voltage; marine scenarios mandate DNV GL certification
- Environment Adaptation: Desert regions require high-temperature resistant + IP55 dustproof models; outdoor applications need moisture-proof models; food industry requires splash-proof + easy-to-clean designs
- Function-Oriented Needs: Process industries value precise control and communication integration; discrete manufacturing focuses on quick start/stop and torque reserve; energy-saving applications emphasize variable flow regulation
- Easy Operation & Maintenance: Intuitive control panel + USB interface and remote monitoring capabilities reduce maintenance pressure on local technical personnel
Frequently Asked Questions
Q1: The voltage standard in my country is 230V single-phase. Can the ACS880 be used directly?
No, the ACS880 is designed for 3-phase input (208-690V) as standard. For 230V single-phase power supplies, you need to use a single-phase-to-3-phase inverter (ensure the inverter's power is 1.5x the drive's power) and choose low-power ACS880 models (≤7.5kW) that are compatible with phase conversion.
Q2: During installation, the drive shows an "EMC fault" alarm. What's wrong?
This is typically related to non-compliance with local EMC standards or incorrect wiring. Check if the built-in EMC filter matches your region, ensure input/output cables are separated by at least 10cm, and verify proper grounding with a 4mm² copper wire and grounding resistance ≤4Ω.
Q3: The drive works fine in the workshop, but when installed on a ship, it often shuts down unexpectedly. Why?
Marine environments require specific certification and protection. Confirm if the model has DNV GL/ABS certification, check that IP55 protection is used for deck equipment, install anti-vibration brackets, and set the drive's "marine mode" in parameters to adapt to voltage fluctuations from the ship's generator.
Q4: I bought a North American version (UL-certified) but need to use it in Southeast Asia. Will there be compatibility issues?
The main risk is voltage mismatch. North American models use 208-240V 60Hz, while Southeast Asia uses 380-480V 50Hz. Don't connect directly - either replace with an international version (-3 suffix) or use a step-up transformer (240V->380V) with transformer power 2x the drive's power.
Q5: The drive's control panel is in English, and our technicians can't operate it. Is there a multilingual option?
Yes, the ACS880's standard control panel supports 10+ languages. Press the "Menu" button, select "Language," and choose your local language. For additional languages, download the ABB Drive composer software which supports 20+ languages for parameter setting via PC.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shanghai Fradwell Industrial Automation Co., Ltd.
Location
No. 168, Chengnan Road, Pudong New Area, 201399 Shanghai, China
Contact Person
Angelo Wu