Shanghai Fradwell Industrial Automation Co., Ltd.
                                                                                                           
Verified Supplier
Years
Since
Menu

GA500 Textile-Specific Inverter Small High-performance Frequency Converter Inverter

Price Negotiable
Price: $300 - $3000
MOQ: 1
Delivery Time: 3-5Workday
Product Description
GA500 Textile-Specific Inverter
A compact vector control inverter with textile machinery-specific functions, providing comprehensive professional solutions. Offers abundant features to reduce time and costs for users in various scenarios, from inverter selection to fault troubleshooting.
Key Features
  • Standard Frequency Sweep Function - Eliminates yarn bobbin bulges and ensures uniform smoothness
    • Fine-tuning of frequency sweep waveform superimposed on sweep speed
    • Frequency sweep waveform ON/OFF switching via external contacts
    • Waveform status (rising/falling) output to peripheral controllers
  • Easy T1000V Replacement - No additional accessories required
    • Compatible dimensions with previous T1000V model
    • Easy wiring on both main circuit and control circuit terminals
DriveWizard Support Tool
Simply connect the inverter to a computer via USB for centralized parameter management. The oscilloscope function enables real-time monitoring, facilitating maintenance workflows.
Technical Specifications
Power Input
Item Specification Remarks
Voltage/Phase 200–240 V (1φ/3φ); 380–480 V (3φ) ±15%/+10% voltage fluctuation; 50/60 Hz ±5%
Capacity Range 240 V 1φ: 0.1–3.7 kW; 240 V 3φ: 0.1–22 kW; 480 V 3φ: 0.2–30 kW HD/ND rating varies by model
Output & Control
Item Specification Remarks
Overload Rating HD: 150% rated current/60 s; ND: 110% rated current/60 s Cycle-based, derate as per manual
Control Modes V/f, Open-loop Vector (IM/PM), Advanced Open-loop (PM), EZ Vector Supports IM/PM/SynRM
Output Frequency 0–590 Hz; up to 1000 Hz (special software) Dependent on motor & control mode
Speed Control Range Typ. 1:200 (open-loop vector) Optimize via motor parameters
I/O & Communication
Item Specification Remarks
Digital I/O 7 DI (sink/source selectable); 1 relay, 2 opto, 1 pulse DO (HTL) Includes pulse input (max 32 kHz)
Analog I/O 2 AI (0–10 V/4–20 mA); 1 AO (voltage/current selectable) For setpoint & feedback
Standard Comm Modbus RTU (RS-485) Optional Ethernet/industrial Ethernet modules
Mechanical & Environmental
Item Specification Remarks
Enclosure Rating IP20 (standard); IP20/UL Type 1 kit (optional) Side-by-side, DIN rail, external heatsink
Ambient Conditions -10–60 °C (derate); ≤95% RH (non-condensing); ≤1000 m (no derate); ≤4000 m (derate) Dust & heat dissipation critical
Safety & Certification
Item Specification Remarks
Safety Rating SIL3 (IEC 62061); PLe (ISO 13849-1) Optional safety options & correct wiring required
Global Certifications CE, UL, cUL, TUV, RCM, CSA RoHS2 compliant; SCCR: 100 kA rms symmetrical
Sample Models (3-Phase 400V Class)
Model Rated Current (HD/ND) Motor Power (HD) Overload Enclosure
GA50C4012EBA 9.2 A/11.9 A 4 kW (5.5 HP) HD 150%/60 s; ND 110%/60 s IP20
Industry Applications
Industry Typical Scenarios Adaptation Points
Food & Beverage Filling line conveyors, labeling machines, sealing/cutting machines Frequent start/stop, smooth speed regulation, PID closed-loop control
Plastics & Rubber Small injection molding machines, extruders, film blowing machines Stable torque control, strong overload capacity, high-frequency output
Machine Tools & Metalworking Auxiliary axes of small machining centers, drilling/tapping machines High-precision speed/torque control, pulse input, optional high-frequency version
Material Handling Belt conveyors, roller lines, hoists, AGV/AMR driving axes High torque at low speeds, low start/stop impact, Modbus RTU/Bluetooth debugging
Frequently Asked Questions
Q1: The inverter shows "Undervoltage Fault (UV)" after power-on, but the local grid voltage is within 380-480V. How to fix it?
Troubleshoot 3 key points: ① Confirm voltage rating matching—replace with model matching grid voltage if incorrect. ② Check if input terminals are loose—retighten main circuit terminals. ③ Verify if grid fluctuations exceed ±15%—install input reactor or enable "Undervoltage Tolerance" function (Parameter P1-07).
Q2: After replacing the old T1000V model, the motor runs with increased noise and unstable speed. What's the issue?
Most likely cause is mismatched parameters: ① Incomplete parameter replication—use DriveWizard to import original T1000V motor parameters. ② Wrong control mode—switch to "Open-Loop Vector Mode (P1-01=2)" for induction motors. ③ Accidental activation of frequency sweep function—set to OFF in Parameter P2-00 if not needed.
Q3: The workshop temperature overseas exceeds 45℃, and the inverter frequently reports "Overheat Fault (OH)". How to resolve it?
Improve heat dissipation: ① Check installation spacing—increase to ≥15cm if side-by-side mounted. ② Clean dust from heatsink. ③ Enable automatic derating—set Parameter P8-20 to "Auto". ④ For long-term high temperatures (>50℃), switch to model with external heatsink.
Q4: When connecting to PLC via Profinet, communication is unstable. How to fix it quickly?
Troubleshoot communication settings: ① Confirm module compatibility—use "GA50-CCN-PN" Profinet module. ② Check IP address and subnet mask—ensure same network segment. ③ Verify wiring quality—use shielded cables, ground shield, limit cable length to ≤100 meters. ④ Reset communication parameters in Parameter P5-00.
Q5: The braking resistor gets extremely hot (even smokes). What's wrong, and how to prevent burnout?
Issue lies in improper resistor selection or parameters: ① Insufficient resistor power—select resistor matching motor power. ② Excessively high braking duty cycle—set Parameter P3-09 to ≤30%. ③ Faulty built-in braking transistor—test with multimeter and replace if damaged.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shanghai Fradwell Industrial Automation Co., Ltd.
Location No. 168, Chengnan Road, Pudong New Area, 201399 Shanghai, China
Contact Person Angelo Wu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.