ACS530 Compact & Reliable Inverter for Global Industrial Drives (0.75-250kW)
Price:
USD650-20000
MOQ:
1
Delivery Time:
3-5Workday
Product Description
ACS530 Compact & Reliable Inverter for Global Industrial Drives (0.75-250kW)
The ACS530 is a general-purpose inverter covering a power range of 0.75-250kW, featuring compact design and high reliability for stable operation in harsh industrial environments. Optimized for fan and pump loads with built-in application macros, it simplifies commissioning while adapting to diverse industrial requirements worldwide.
Core Product Features
Compact Design for High Space Utilization
Features optimized heat dissipation and modular layout, 15-20% smaller than traditional inverters. Standardized frame sizes (R1-R8) compatible with 19-inch racks for efficient cabinet installation in space-constrained applications.
High Reliability for Harsh Working Conditions
IP21 protection (IP54 optional) with coated circuit boards resists dust, moisture, and corrosive gases. Wide input voltage range (380-480V AC±10%) handles grid fluctuations. Comprehensive protection functions with international fault codes.
Specialized Optimization for Fans & Pumps
Built-in control macros for fan/pump applications including constant pressure water supply and ventilation. Optimized V/F curve matches load characteristics, achieving 15-35% energy savings with PID closed-loop control.
Flexible Expansion for System Integration
Standard Modbus RTU with expandable PROFIBUS DP, DeviceNet, EtherNet/IP, and PROFINET interfaces. Supports 16-step speed control, timing functions, and multi-motor switching for diverse industrial applications.
Easy Maintenance for Low Lifecycle Costs
Modular design enables quick component replacement. Global spare parts availability with 2-10 day delivery. Remote diagnosis capabilities and 10-year design life with MTBF exceeding 100,000 hours.
Core Specifications
| Parameter Category | Specific Parameters | Details |
|---|---|---|
| Power Range | Rated Power | 0.75 - 250kW (1 - 335hp) |
| Voltage Specifications | Input Voltage | Three-phase 380-480V AC±10%; Single-phase 230V AC±10% (0.75-2.2kW models) |
| Control Functions | Control Modes | V/F Control (fan/pump optimized), Sensorless Vector Control |
| Control Functions | Speed Regulation Range | 0.5 - 60Hz |
| Control Functions | PID Regulation Accuracy | ±0.5% |
| Communication Interfaces | Standard Interface | Modbus RTU (RS-485) |
| Communication Interfaces | Optional Interfaces | PROFIBUS DP, DeviceNet, EtherNet/IP, PROFINET |
| Structure & Protection | Protection Class | Standard: IP21; Optional IP54 enclosure |
| Structure & Protection | Installation Method | Cabinet-mounted, Wall-mounted (IP54 models) |
| Environmental Adaptability | Operating Temperature | -10℃ - 50℃ (derated to 60℃) |
| Environmental Adaptability | Anti-Interference Design | Class C3 EMC filter, compliant with EN 61800-3 |
| Energy-Saving Features | Core Energy-Saving Functions | Fan/pump optimized V/F curve, PID closed-loop control, Sleep/Wake-up function |
| Protection Functions | Core Protection Functions | Overcurrent, Overvoltage, Overheating, Phase loss, Motor overload, PID feedback loss, Ground fault protection |
Model Specifications
| Model | Output Current (A) | Motor Power (kW) | Motor Power (hp) | Input Voltage | Frame Size | EMC Class | Core Features | Application Scenarios |
|---|---|---|---|---|---|---|---|---|
| ACS530-01-01A3-4 | 1.3 | 0.75 | 1 | 380-480V AC±10% | R1 | C3 | Standard V/F control, Modbus RTU | Small cooling pumps, laboratory ventilation fans |
| ACS530-01-02A1-4 | 2.1 | 1.1 | 1.5 | 380-480V AC±10% | R1 | C3 | Fan/pump optimized macro | Small conveyors, printing machines |
| ACS530-01-02A6-4 | 2.6 | 1.5 | 2 | 380-480V AC±10% | R1 | C3 | PID closed-loop control | Small constant pressure water supply pumps |
| ACS530-01-03A6-4 | 3.6 | 2.2 | 3 | 380-480V AC±10% | R1 | C3 | Sensorless vector control | Medium ventilation fans, machine tool cooling pumps |
| ACS530-01-04A5-4 | 4.5 | 3 | 4 | 380-480V AC±10% | R2 | C3 | 16-step speed control | Industrial cooling pumps, packaging machinery |
| ACS530-01-06A2-4 | 6.2 | 4 | 5.5 | 380-480V AC±10% | R2 | C3 | Multi-motor switching | Medium constant pressure water supply pumps |
| ACS530-01-08A0-4 | 8.0 | 5.5 | 7.5 | 380-480V AC±10% | R2 | C3 | Sleep/wake-up function | Industrial ventilation fans, sewage treatment pumps |
| ACS530-01-09A7-4 | 9.7 | 7.5 | 10 | 380-480V AC±10% | R2 | C3 | High overload capacity | Large cooling pumps, mine ventilation fans |
| ACS530-01-13A8-4 | 13.8 | 11 | 15 | 380-480V AC±10% | R3 | C3 | PROFINET expandable | Production line conveyors, large ventilation fans |
| ACS530-01-17A2-4 | 17.2 | 15 | 20 | 380-480V AC±10% | R3 | C3 | EtherNet/IP expandable | Industrial circulation pumps, booster pumps |
| ACS530-01-25A4-4 | 25.4 | 18.5 | 25 | 380-480V AC±10% | R3 | C3 | Multi-pump linkage | Large constant pressure water supply systems |
| ACS530-01-31A0-4 | 31.0 | 22 | 30 | 380-480V AC±10% | R4 | C3 | IP54 optional | Mine ventilation fans, large industrial fans |
| ACS530-01-43A0-4 | 43.0 | 30 | 40 | 380-480V AC±10% | R4 | C3 | Ground fault protection | Sewage treatment aerators, circulation pumps |
| ACS530-01-59A0-4 | 59.0 | 45 | 60 | 380-480V AC±10% | R5 | C3 | High-voltage drop mode | Large industrial cooling systems, water supply stations |
| ACS530-01-72A0-4 | 72.0 | 55 | 75 | 380-480V AC±10% | R5 | C3 | Remote diagnosis support | Mine main ventilation fans, central AC fans |
| ACS530-01-92A0-4 | 92.0 | 75 | 100 | 380-480V AC±10% | R6 | C3 | EMC C2 optional | Ultra-large industrial fans, high-pressure pumps |
| ACS530-01-125A0-4 | 125.0 | 90 | 125 | 380-480V AC±10% | R6 | C3 | Enhanced heat dissipation | Large industrial circulation systems |
| ACS530-01-155A0-4 | 155.0 | 110 | 150 | 380-480V AC±10% | R7 | C3 | PID auto-tuning | Ultra-large ventilation fans, sewage treatment |
| ACS530-01-180A0-4 | 180.0 | 132 | 175 | 380-480V AC±10% | R7 | C3 | Multi-bus support | Industrial giant cooling fans, urban water supply |
| ACS530-01-220A0-4 | 220.0 | 160 | 215 | 380-480V AC±10% | R8 | C3 | IP54 standard | Ultra-large industrial fluid systems |
| ACS530-01-260A0-4 | 260.0 | 200 | 268 | 380-480V AC±10% | R8 | C3 | Heavy-duty design | Ultra-large mine ventilation fans, circulation pumps |
| ACS530-01-310A0-4 | 310.0 | 250 | 335 | 380-480V AC±10% | R8 | C3 | Extended warranty optional | Ultra-large industrial cooling systems |
| ACS530-01-01A3-4+C2 | 1.3 | 0.75 | 1 | 380-480V AC±10% | R1 | C2 | Low electromagnetic interference | Precision laboratory equipment |
| ACS530-01-03A6-4+C2 | 3.6 | 2.2 | 3 | 380-480V AC±10% | R1 | C2 | Low-noise operation | Food processing, clean room ventilation |
| ACS530-01-17A2-4+IP54 | 17.2 | 15 | 20 | 380-480V AC±10% | R3 | C3 | Dustproof and waterproof | Outdoor irrigation pumps, coastal ventilation |
Applicable Industries & Scenarios
| Industry | Application Scenarios | Adaptation Advantages |
|---|---|---|
| Industrial Manufacturing | Production line conveyors, machine tool cooling pumps, packaging machinery | Compact design, multi-step speed control, high reliability for 24/7 operation |
| Municipal Water Supply/Wastewater Treatment | Constant pressure water supply, sewage treatment aeration, booster pump stations | Pump-specific macros, precise PID regulation, significant energy savings |
| HVAC | Central air conditioning, hotel circulation pumps, industrial ventilation | Building automation integration, low-noise operation, indoor compliance |
| Mining/Building Materials | Mine ventilation, cement production cooling, stone processing conveyors | High protection class, dust/moisture resistance, wide voltage adaptation |
| Agriculture/Fisheries | Farm irrigation, fish pond aerators, grain drying fans | Energy-saving features, wide temperature tolerance, outdoor suitability |
| Food & Beverage | Food processing conveyors, beverage filling, cold storage cooling | Hygienic design, low-noise operation, low electromagnetic interference |
Frequently Asked Questions
Q1: Speed drift occurs when connecting to PLC via PROFINET in automotive parts factory
Reduce PROFINET update cycle to 20-50ms, switch to sensorless vector control with motor auto-tuning, check mechanical components for wear, and enable speed command filtering in PLC.
Q2: Overcurrent fault with normal measured current in sewage treatment aeration fans
Verify motor rated current parameter matches nameplate, check for loose/oxidized wiring, adjust overcurrent protection threshold to 180%, extend acceleration time, and clean fan impeller.
Q3: Overheating and undervoltage faults in high-dust mine environment with voltage fluctuations
Upgrade to IP54 model with dust filter, clean heat sinks, install voltage stabilizer, adjust undervoltage protection threshold, and enable derated operation for high temperatures.
Q4: Communication disconnections with building automation system via EtherNet/IP
Separate communication/power cables, use shielded cables with terminal resistors, increase communication timeout to 10s, upgrade firmware, and set communication fault tolerance.
Q5: Electromagnetic interference causing color deviation in precision printing machines
Install EMC filter and output reactor, increase switching frequency to 8kHz, optimize cable separation, ensure proper grounding, and install signal isolators if needed.
Q6: Temperature fluctuations in reactor cooling pump PID control
Adjust PID parameters (reduce proportional gain, increase integral time), enable PID filter function, optimize sensor placement, and extend pump acceleration/deceleration times.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shanghai Fradwell Industrial Automation Co., Ltd.
Location
No. 168, Chengnan Road, Pudong New Area, 201399 Shanghai, China
Contact Person
Angelo Wu