SINAMICS G120C Compact & Versatile Frequency Inverter for Global Industrial Applications
Price:
$280 - $6500
MOQ:
1
Delivery Time:
3-5Workday
Product Description
SINAMICS G120C Compact & Versatile Frequency Inverter
The SINAMICS G120C is an extremely compact frequency converter with integrated safety functions and comprehensive features suitable for diverse global industrial applications. Available in 7 frame sizes covering 0.55 kW to 132 kW power range.
Compact Design for Space-Constrained Installations
Maintains compact structure even at 132 kW power rating with 7 frame sizes accommodating various installation requirements. Integrated input reactor and EMC filter with all frame sizes supporting side-by-side mounting without power reduction or current derating.
- Low-power models (0.55-2.2 kW): 73×173×155 mm for small control cabinets
- High-power models (110-132 kW): 305×708×368 mm, more compact than comparable units
- Pluggable power and motor terminals for easy maintenance
- Replaceable heatsink fan for convenient servicing
Integrated Safety Functions
Standard Safe Torque Off (STO) function immediately blocks pulses and reduces output torque to zero, eliminating need for external safety components. Expandable safety features with CU250s-2 control units include Safe Brake Control (SBC), Safe Stop 1 (SS1), and Safe Limited Speed (SLS).
- Controlled via fail-safe inputs or PROFIsafe communication
- Compliant with IEC 61800-5-2 safety standard
- Suitable for pumps, cranes, conveyors and other safety-critical equipment
Versatile Multi-Domain Functions
Control & Energy Saving
Energy-efficient sensorless vector control delivers high torque at low frequencies for low-speed, heavy-load scenarios. V/f ECO mode automatically reduces magnetic flux to cut energy consumption with integrated energy-saving calculator for real-time monitoring.
Communication Compatibility
Supports mainstream bus systems including PROFINET, EtherNet/IP, and PROFIBUS for seamless integration into industrial control systems. Achieves high-efficiency communication with SIMATIC S7 series PLCs in automated production lines.
Easy Operation
Parameter setting and data cloning via BOP-2 basic operator panel, IOP-2 intelligent operator panel, or SD card. Wireless commissioning through smart access modules using mobile phones or computers simplifies the commissioning process.
Core Specifications
| Parameter Category | Key Indicators | Notes |
|---|---|---|
| Power & Frame Size | 0.55-132 kW, 7 frame sizes | Side-by-side mounting without derating; integrated input reactor and EMC filter |
| Typical Dimensions | 0.55-2.2 kW: 73×173×155 mm 110-132 kW: 305×708×368 mm |
W×H×D (Width×Height×Depth); refer to specific model nameplate |
| Control Modes | Sensorless Vector Control, V/f, V/f ECO | High torque at low frequencies; V/f ECO automatically reduces flux for energy savings |
| Safety Functions | Standard: STO; Expandable: SBC, SS1, SLS | Supports fail-safe inputs/PROFIsafe; compliant with IEC 61800-5-2 |
| Communication Support | PROFINET, EtherNet/IP, PROFIBUS | Integrates with TIA Portal; high-efficiency communication with SIMATIC S7 |
| I/O Interfaces | 6 DI, 2 DO, 1 AI, 1 AO | Supports 0-10 V/4-20 mA; compatible with standard control links |
| Overload Capacity | Typical HO: 200% for 3 s; LO: 150% for 3 s | Dependent on model and ambient temperature; derating required at 60 °C |
| Protection Class | IP20 (Open Type) | Cabinet-mounted installation; environmental cleanliness must be compatible |
| Ambient Temperature | 0-40 °C: No derating; 40-60 °C: Derated operation | Heat dissipation and ventilation directly affect continuous output |
| Operation & Commissioning | BOP‑2/IOP‑2 panels, SD card cloning, wireless commissioning | Supports parameter backup and batch replication; shortens commissioning time |
Overseas Market Models (3AC 380-480 V)
| Rated Power (kW) | Order Number | Rated Current (A) | Dimensions (W×H×D, mm) | Notes |
|---|---|---|---|---|
| 0.55 | 6SL3210-1KE11-8UF1 | 1.8 | 73×173×155 | Side-by-side mounting without derating |
| 0.75 | 6SL3210-1KE12-3UF1 | 2.3 | 73×173×155 | Standard BOP-2/SD card included |
| 1.1 | 6SL3210-1KE13-2UF1 | 3.2 | 73×173×155 | Suitable for light-load general applications |
| 2.2 | 6SL3210-1KE15-8UF1 | 5.8 | 73×173×155 | Compact design for small control cabinets |
| 4.0 | 6SL3210-1KE21-1UF1 | 11.0 | 140×295×205 | Popular choice for 4-7.5 kW applications |
| 7.5 | 6SL3210-1KE21-7UF1 | 17.0 | 140×295×205 | Optimized for quadratic torque loads |
| 11.0 | 6SL3210-1KE22-6UF1 | 26.0 | 140×295×205 | Sensorless vector control for low-speed heavy loads |
| 15.0 | 6SL3210-1KE23-2UF1 | 32.0 | 140×295×205 | Commonly used in production lines |
| 18.5 | 6SL3210-1KE23-8UF1 | 38.0 | 140×295×205 | Expandable to SBC/SS1 |
| 22.0 | 6SL3210-1KE31-4UF1 | 44.0 | 210×440×285 | Preferred for pumps/fans |
| 30.0 | 6SL3210-1KE32-1UF1 | 61.0 | 210×440×285 | No derating for side-by-side installation |
| 45.0 | 6SL3210-1KE33-1UF1 | 91.0 | 210×440×285 | High power density |
| 55.0 | 6SL3210-1KE34-4UF1 | 110.0 | 210×440×285 | Single frame for 55 kW |
| 75.0 | 6SL3210-1KE35-5UF1 | 155.0 | 305×708×368 | Suitable for machine-mount installation |
| 90.0 | 6SL3210-1KE36-0UF1 | 180.0 | 305×708×368 | Easy-to-replace cooling fan |
| 110.0 | 6SL3210-1KE36-6UF1 | 210.0 | 305×708×368 | High overload option available |
| 132.0 | 6SL3210-1KE37-7UF1 | 264.0 | 305×708×368 | More compact than peers in same power class |
Industry Application Scenarios
| Industry Sector | Application Scenarios | Key Adaptability Points |
|---|---|---|
| General Machinery | Spindle speed control for machine tools; Packaging machine speed control; Fan speed regulation for plastic processing | Compact design; Sensorless vector control; V/f ECO energy savings |
| HVAC & Water Treatment | HVAC fan/pump control; Desalination plant pumps; Wastewater treatment aeration | Multi-pump cascade control; Integrated EMC filter; Wide voltage tolerance |
| Food & Beverage | Wine filling lines; Coffee roasters; Beverage production mixers | Quick start/stop; STO safety function; Easy-to-clean design |
| Logistics & Warehousing | Warehouse stacker cranes; Sorting center conveyors; Port conveyor belts | Expandable safe stop; PROFINET communication; Compact installation |
| Chemical & Pharmaceutical | Chemical reactor agitators; Pharmaceutical transfer pumps; Coating dispersers | EMI-resistant design; Wide temperature range; Strong overload capacity |
| Agriculture & Irrigation | Farm irrigation pumps; Orchard spray systems; Paddy field drainage | Low-voltage ride-through; Energy-saving mode; Suitable for outdoor cabinets |
| Mining & Building Materials | Mine ventilation fans; Cement mixing conveyors; Tile production grinders | High torque startup; Durable design; Multi-machine cascade support |
Frequently Asked Questions
Purchase & Ordering
Q: Can I use the same order number for EU and US markets? Do certifications differ?
A: Order numbers vary by region—US models require UL/cUL certification while EU models need CE marking. Specify your target market when ordering. Core parameters remain the same with certification-related component adjustments.
Q: Do I need to buy additional accessories separately?
A: Base unit includes integrated EMC Class A filter and basic wiring terminals. Optional accessories include local language operator panels, brake resistors for frequent braking, and wireless commissioning modules.
Installation & Wiring
Q: The inverter gets overheated during side-by-side installation—what's wrong?
A: Ensure minimum gap specifications (FSA/FSD: 50mm; FSF: 100mm) between units. Overheating causes include insufficient gaps, poor cabinet ventilation, or ambient temperatures exceeding 40°C requiring derating.
Q: Why does the inverter display an "EMC fault" after wiring? (North American users)
A: Typically caused by incorrect grounding or unshielded cables. Ensure dedicated ground connection (resistance ≤4Ω), use shielded twisted-pair motor cables (length ≤50m), and maintain 300mm separation from power cables.
Q: Can the inverter be installed outdoors?
A: IP20 rating requires indoor cabinet installation. For outdoor use, employ weatherproof cabinet (IP54+) with sunshade and heater for temperatures below 0°C. Never mount directly outdoors.
Commissioning & Operation
Q: The motor doesn't start—how to troubleshoot quickly?
A: Check run command reception via BOP-2 manual start, verify motor wiring, confirm parameter P0731 setting, or reset to factory defaults if settings were modified incorrectly.
Q: How to copy parameters from one inverter to multiple units?
A: Use SD card method: Save parameters from master inverter (P0010=10), then load to slave units (P0010=11). Ensure same frame size and power rating for all units.
Q: The inverter saves energy, but the motor makes noise at low speeds—why?
A: Normal for sensorless vector control. Reduce noise by switching to V/f ECO mode for fans/pumps, increasing low-speed damping parameter for heavy loads, or checking motor bearing condition.
Key Selection Guidelines: Mainstream specification: 3AC 380-480 V (±10%/-20%), 47-63 Hz. EMC Class A filter compliant with EN 61800-3. Standard PROFINET/ENIP with expandable bus options. STO safety standard with expandable functions. 7 frame sizes support side-by-side mounting without derating.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shanghai Fradwell Industrial Automation Co., Ltd.
Location
No. 168, Chengnan Road, Pudong New Area, 201399 Shanghai, China
Contact Person
Angelo Wu