MELSEC iQ-F PLC – Your Trusted Partner for Global Industrial Automation
Price:
USD88-2100
MOQ:
1
Delivery Time:
3-5workdays
Product Description
As a reliable core control solution for industrial automation projects worldwide, MELSEC iQ-F PLC series covers full-range models including FX5U, FX5UC, FX5UJ and FX5S, integrating advantages like high-speed control, integrated communication, flexible expansion and global protocol compatibility. It is tailored to diverse application scenarios from small standalone equipment to large-scale smart factories, providing stable and efficient control support for overseas factories and production lines.
Key Features & Benefits
- Full Model Range: Covers four major series (FX5U/FX5UC/FX5UJ/FX5S) from entry-level to high-end flagship models, meeting diverse industrial automation needs.
- Integrated Performance: Built-in Ethernet and RS-485 communication ports, supports 4-axis 200kHz high-speed positioning and multi-channel high-speed counting for complex control tasks.
- Global Protocol Compatibility: Seamlessly supports mainstream industrial protocols including Modbus and Ethernet/IP, adapting to international communication standards.
- Compact & Flexible Design: Ultra-compact FX5UC series saves installation space while supporting flexible I/O expansion and global power supply compatibility.
- Cost-Effective Solutions: Tiered product selection from economical FX5UJ/FX5S to high-performance FX5U models, balancing cost and functionality.
- Global Reliability: High anti-interference capability and stable operation performance for harsh industrial environments worldwide.
Product Model Specifications
| Series | Specific Model | I/O Points | Power Supply | Output Type | Core Features |
|---|---|---|---|---|---|
| FX5U | FX5U-32MR/ES | 32 points | AC | Relay | Built-in Ethernet & RS-485, 6-channel 200kHz counter |
| FX5U | FX5U-32MT/ES | 32 points | AC | Transistor (Sink) | 4-axis 200kHz positioning, 6-channel counter |
| FX5U | FX5U-32MT/ESS | 32 points | AC | Transistor (Source) | Diverse wiring compatibility, 6-channel counter |
| FX5U | FX5U-64MR/ES | 64 points | AC | Relay | 8-channel 200kHz high-speed counter |
| FX5U | FX5U-64MT/ES | 64 points | AC | Transistor (Sink) | 4-axis positioning, 8-channel counter |
| FX5U | FX5U-64MT/ESS | 64 points | AC | Transistor (Source) | High expandability, 8-channel counter |
| FX5U | FX5U-80MR/ES | 80 points | AC | Relay | Medium-scale projects, 8-channel counter |
| FX5U | FX5U-80MT/ESS | 80 points | AC | Transistor (Source) | High expandability, 8-channel counter |
| FX5U | FX5U-32MR/DS | 32 points | DC | Relay | DC power scenarios, 6-channel counter |
| FX5UC | FX5UC-32MT/D | 32 points | DC | Transistor (Sink) | Compact design for small equipment |
| FX5UC | FX5UC-32MT/DSS | 32 points | DC | Transistor (Source) | Spring terminal wiring support |
| FX5UC | FX5UC-32MT/DS-TS | 32 points | DC | Transistor (Sink) | Spring clamp terminal block |
| FX5UC | FX5UC-64MT/D | 64 points | DC | Transistor (Sink) | Medium-scale compact systems |
| FX5UC | FX5UC-96MT/DSS | 96 points | DC | Transistor (Source) | Highest I/O in FX5UC series |
| FX5UJ | FX5UJ-24MR/ES | 24 points | AC | Relay | Cost-effective small-scale control |
| FX5UJ | FX5UJ-24MT/ESS | 24 points | AC | Transistor (Source) | Basic high-speed counting |
| FX5UJ | FX5UJ-24MR/DS | 24 points | DC | Relay | Low-power consumption applications |
| FX5S | FX5S-30MR/ES | 30 points | AC | Relay | Entry-level, low cost, easy operation |
| FX5S | FX5S-30MT/ES | 30 points | AC | Transistor | Entry-level, low cost, easy operation |
Technical Specifications Comparison
| Parameter | FX5U (Flagship) | FX5UC (Compact) | FX5UJ (Cost-Effective) | FX5S (Entry-Level) |
|---|---|---|---|---|
| CPU Performance | 34ns LD instruction speed | Same as FX5U | ~2x faster than FX3U | Basic high-speed processing |
| Program Memory | 128k steps | 128k steps | 64k steps | 32k steps |
| Controllable I/O | Up to 512 points | Up to 512 points | Up to 256 points | Up to 256 points |
| Built-in Communication | Ethernet + RS-485 | Same as FX5U | Ethernet + RS-485 Lite | Basic Ethernet + RS-485 |
| Analog I/O | Built-in 2×12-bit input + 1×12-bit output | Expansion required | Expansion required | Expansion required |
| High-Speed Counter | 8 channels @ 200kHz | Same as FX5U | 4 channels @ 100kHz | 4 channels @ 100kHz |
| Positioning Function | 4-axis @ 200kHz | Same as FX5U | 2-axis @ 100kHz | 2-axis @ 100kHz |
| Special Functions | SD card, web server, security | Same as FX5U | USB Mini-B programming | Basic SD card logging |
| Power Supply | AC/DC global compatible | DC power mainly | AC/DC optional | DC power |
Global Application Scenarios
Automotive Component Manufacturing: Used in Southeast Asia and Europe for automotive component processing and assembly lines with high-precision positioning and real-time response capabilities.
Electronic Appliance Production: Applied in Japan, South Korea, Europe and America for production line control of small electronic devices with analog I/O and Modbus communication.
Food Processing & Packaging: Implemented in Europe and North America for food processing equipment control with compact design and RS-485 connectivity for temperature and weight regulation.
Warehousing & Logistics Automation: Used worldwide in automated warehouses and sorting centers for conveyor and stacker control with high-speed counting and Ethernet connectivity.
Chemical & Pharmaceutical Equipment: Applied in Southeast Asia and Europe for laboratory-scale batching and reactor systems with analog expansion and security features.
Frequently Asked Questions
Wiring & Installation
No response from input terminals after wiring with normal 24V voltage?
Check for incompatible input devices with built-in diodes or parallel resistors. Test by short-circuiting COM and input terminals, and verify extension cable connections.
Output terminals stay energized without normally-on commands?
Inspect for external wiring short circuits, use peripheral tools to force outputs off, and check for duplicate coils or RST commands in the program.
Poor contact with European-style terminal blocks?
Avoid tinning wire ends, use specified wire sizes, tighten with proper torque values, and prevent screwdriver contact with terminal partitions.
Communication & Compatibility
IP address conflicts with CC-Link IE TSN networks?
Check for duplicate IP addresses, wait for ARP cache refresh, reboot network components together, and enable IP filtering settings.
Ethernet communication data transmission errors?
Verify ARP cache synchronization, set standard subnet masks, check firewall settings blocking communication ports.
Environmental Adaptation
Frequent PLC crashes in corrosive environments?
Check dust-proof film removal, ensure flat mounting surface, secure modules properly with DIN rails, and fasten expansion boards with correct torque.
Output terminal failures after power outage recovery?
Power all modules on/off simultaneously, wait 5 minutes before restarting, check DC24V power supply for overload conditions.
Maintenance & Operation
Safe program modification during operation?
Add interlock circuits, modify programs step by step using GX Works3, compile offline before downloading, avoid multiple peripheral modifications.
SD card recognition issues?
Ensure proper insertion, ground yourself to discharge static, limit insertion/removal cycles to prevent contact point wear.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shanghai Fradwell Industrial Automation Co., Ltd.
Location
No. 168, Chengnan Road, Pudong New Area, 201399 Shanghai, China
Contact Person
Angelo Wu