XL5N CAN Communication Controller: Compact Size, Large Capacity, Dual Independent CAN Channels
Price:
$300-- $380
MOQ:
1
Delivery Time:
3-5workdays
Product Description
XL5N CAN Communication Controller: Compact Size, Large Capacity, Dual Independent CAN Channels
The XL5N CAN Communication Controller is a compact, high-performance industrial control device designed for space-constrained installations requiring reliable multi-device communication. With its small footprint, it integrates seamlessly into tight control cabinets while offering large-capacity program and data storage for complex logic control and long-term data logging. The dual independent CAN communication channels enable simultaneous connection to separate CAN networks or redundant setups, ensuring stable data transmission between sensors, actuators, and control systems.
Key Features & Advantages
- Ultra-compact form factor: Space-saving design for narrow control cabinets and distributed control nodes
- Large-capacity storage: High-capacity FlashROM and RAM for complex programs and historical data logging
- Dual independent CAN channels: Two isolated CAN ports for separate networks or redundant communication
- Strong compatibility: Supports CAN 2.0A/B protocols and multiple industrial device connections
- Industrial-grade reliability: Anti-electromagnetic interference, wide temperature resistance (0-55℃), and IP20 protection
- Easy configuration: Online program download, parameter modification, and user-friendly interface
Technical Specifications
| Parameter Category | Specifications | Remarks |
|---|---|---|
| Basic Configuration | ||
| Model | XL5N-32T | |
| I/O Points | 32 (16 inputs, 16 outputs) | Transistor output (NPN/PNP optional) |
| Form Factor | Ultra-compact | Saves installation space in cabinets |
| Power Supply | DC24V | Voltage tolerance: 20.4V-26.4V |
| Memory Capacity | ||
| User Program Memory | 1MB FlashROM | Supports complex logic & long-term storage |
| Data Memory | 128KB RAM | With 3V lithium battery backup |
| CAN Communication | ||
| CAN Channels | 2 independent, isolated | CAN1: CANopen master/slave or CANbus; CAN2: CANbus only |
| Supported Protocols | CAN 2.0A/B, CANopen | Standard/extended data frames |
| Max Communication Rate | 1Mbps | Compliant with ISO 11898-2 |
| Additional Interfaces | ||
| Serial | RS232 ×1, RS485 ×1 | Supports Modbus ASCII/RTU |
| Ethernet | 1 port | Supports Modbus TCP, TCP/IP |
| Performance | ||
| Basic Instruction Speed | 0.03μs | Fast program execution |
| High-Speed Counting | 3 channels (AB phase) | For precise position tracking |
| High-Speed Pulse Output | 2 axes | For motion control applications |
| Environmental Adaptability | ||
| Operating Temperature | 0°C-55°C | Industrial-grade reliability |
| Storage Temperature | -20°C-70°C | |
| EMC Protection | Compliant with CE/UL | Anti-electrostatic, anti-surge |
| Protection Level | IP20 | For panel mounting |
| Expansion Capability | ||
| Expansion Modules | Up to 16 XL series modules | Left ED, right I/O expansion |
Application Scenarios
- Overseas Small and Medium-sized Automated Production Lines: Ideal for space-constrained electronics and hardware processing industries in Europe, America, and Southeast Asia. Dual CAN channels separate detection and execution networks to prevent signal interference.
- European Intelligent Logistics and Warehousing Equipment: Perfect for AGV/AMR robots and sorting lines where compact size and mobility are crucial. Supports simultaneous vehicle control and dispatching system communication.
- North American Agricultural Machinery: Suitable for intelligent irrigation equipment and small harvesters operating in outdoor environments with wide temperature variations and harsh conditions.
- Japanese and Korean Small Medical Devices: Embedded control for rehabilitation equipment and laboratory testing instruments requiring high precision and data traceability.
- Central and Eastern European Construction Machinery: Robust performance for small excavators and loaders operating in harsh mining and construction environments.
Common Installation & Operation Issues
Q1: Controller can't connect to CAN network after wiring
Enable built-in termination resistors via configuration software and verify CAN_H/CAN_L wiring is correct.
Q2: Unexpected restarts during rainy season
Improve cabinet sealing with waterproofing and install DC24V voltage stabilizer with surge protection.
Q3: Dual CAN channels interfering with each other
Separate CAN cables by at least 10cm, use shielded twisted-pair cables, and implement proper star-shaped grounding.
Q4: High-temperature operation requirements in Middle East
Relocate control cabinet to shaded area, add ventilation fans, and regularly check wiring terminals.
Q5: Data transmission delays with Japanese touch screens
Verify protocol compatibility and ensure baud rate, data bits, stop bits, and parity bits match exactly.
Q6: Data loss after power outages
Install UPS for temporary power backup and configure automatic data saving to FlashROM at regular intervals.
Q7: Expansion modules not recognized
Verify module count doesn't exceed 16, check expansion bus wiring and connections, and ensure module compatibility.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shanghai Fradwell Industrial Automation Co., Ltd.
Location
No. 168, Chengnan Road, Pudong New Area, 201399 Shanghai, China
Contact Person
Angelo Wu