LYD1-C40/385 Surge Protector Relay Surge Protection 40kA 385VAC For PV
Price:
$5-$30
MOQ:
1
Delivery Time:
3-5Workday
Product Description
Surge Protector LYD1-C40/385, 40kA 385VAC, for PV & Industrial Use, CE Certified, Fast Installation
Surge Protector LYD1-C40/385
High-performance 40kA 385VAC surge protection device designed for photovoltaic systems and industrial applications. CE certified with fast installation capabilities for reliable electrical safety protection.
Key Features: 40kA surge capacity, 385VAC rating, CE certified, DIN rail mounting, fast installation
Product Specifications
| Product Type | Model Series | Key Parameters | Typical Applications |
|---|---|---|---|
| AC Surge Protective Device (SPD) | LYD1-C40/385 | Class C (II), Uc=385VAC, Imax=40kA, Up≤1.8kV | Secondary surge protection for three-phase power distribution, industrial workshops, equipment rooms, building distribution boxes |
| Single-phase Terminal SPD | HS-40D | Class D (III), Uc=275VAC, Imax=40kA, Up≤1.5kV | Single-phase 220V household & commercial terminals, socket boxes, front ends of weak current equipment |
| Composite Surge Protective Device | WR-T1T2-AC | T1+T2 Composite, 275VAC, Imax=20kA | Main power distribution of buildings, outdoor equipment, simplified primary + secondary protection |
| PV DC Surge Protective Device | LYD1-PV1000 | DC 1000V, Imax=20kA | High-voltage DC side surge protection for PV power stations, strings and inverters |
| PV DC Surge Protective Device | HS-PV600 | DC 600V, Imax=20kA | Distributed PV, household PV, small PV systems |
Application Industries
- Construction Industry
- New Energy (Photovoltaic) Industry
- Industrial Manufacturing Industry
- Commercial Retail Industry
- Data Center and Communication Industry
- Outdoor Engineering Industry
- Residential Electricity Field
- Medical and Food Processing Industry
Frequently Asked Questions
Can Heschen protectors be used directly in European countries?
Yes. Most models (e.g., LYD1-C40/385, HS-40D) have CE and VDE certifications, meet EU electrical standards, and can be used directly.
What does it mean when the SPD indicator turns red?
A red light means the SPD is faulty or has been damaged by surges. Replace it immediately to avoid losing protection.
Is the 385V SPD suitable for North America's 120/240V power grid?
No. The 385V model is for 380V three-phase systems. For North America, choose 275V single-phase models (e.g., HS-40D).
Do I need to install a fuse before the SPD?
Yes. It's recommended to install a 63A fuse or circuit breaker to prevent short circuits and protect the SPD.
Can PV DC SPDs (e.g., LYD1-PV1000) be used for AC circuits?
No. DC SPDs are designed specifically for DC circuits. Using them for AC will damage the device and fail to provide protection.