QUINT-PS/1AC/24DC/5/CO Phoenix Contact Power supply, with protective coating 2320908
Primary-switched power supply unit QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input: 1-phase, output: 24 V DC / 5 A
QUINT POWER power supplies with maximum functionality
QUINT POWER circuit breakers magnetically and therefore quickly trip at six times the nominal current, for selective and therefore cost-effective system protection. In addition, the high system availability is ensured by preventive function monitoring which reports critical operating states before errors can occur.
Reliable starting of heavy loads takes place via the static power reserve POWER BOOST. Thanks to the adjustable voltage, all ranges between 18 V DC ... 29.5 V DC are covered.
| AC operation | |
| Nominal input voltage range | 100 V AC ... 240 V AC |
| Input voltage range | 85 V AC ... 264 V AC |
| Electric strength, max. | 300 V AC |
| Voltage type of supply voltage | AC |
| Inrush current | < 15 A |
| Inrush current integral (I2t) | < 1 A2s |
| Inrush current limitation | 15 A |
| AC frequency range | 45 Hz ... 65 Hz |
| Frequency range DC | 0 Hz |
| Mains buffering time | typ. 55 ms (120 V AC) |
| typ. 55 ms (230 V AC) | |
| Current consumption | 1.5 A (100 V AC) |
| 0.6 A (240 V AC) | |
| Nominal power consumption | 141 VA |
| Protective circuit | Transient surge protection; Varistor |
| Typical response time | < 0.15 s |
| Input fuse | 5 A (slow-blow, internal) |
| Permissible backup fuse | B6 B10 B16 AC: |
| Recommended breaker for input protection | 6 A ... 16 A (AC: Characteristics B, C, D, K) |
| Discharge current to PE | < 3.5 mA |
| DC operation | |
| Nominal input voltage range | 110 V DC ... 250 V DC |
| Input voltage range | 110 V DC ... 250 V DC -18 % ... +64 % (UL 508: ≤ 250 V DC) |
| Voltage type of supply voltage | DC |
| Current consumption | 1.3 A (110 V DC) |
| 0.55 A (250 V DC) | |
| Efficiency | typ. 88.3 % (120 V AC) |
| typ. 90 % (230 V AC) | |
| Nominal output voltage | 24 V DC ±1 % |
| Setting range of the output voltage (USet) | 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity) |
| Nominal output current (IN) | 5 A (-25 °C ... 60 °C, UOUT = 24 V DC) |
| POWER BOOST (IBoost) | 7.5 A (-25 °C ... 40 °C permanent, UOUT = 24 V DC ) |
| Selective Fuse Breaking (ISFB) | 30 A (12 ms) |
| Magnetic circuit breaker tripping | B2 / B4 / C2 |
| Derating | 60 °C ... 70 °C (2.5 %/K) |
| Feedback voltage resistance | ≤ 35 V DC |
| Protection against overvoltage at the output (OVP) | ≤ 32 V DC |
| Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
| < 2 % (change in load, dynamic 10 % ... 90 %) | |
| < 0.1 % (change in input voltage ±10 %) | |
| Residual ripple | < 40 mVPP (with nominal values) |
| Output power | 120 W |
| 180 W | |
| Maximum no-load power dissipation | 3 W |
| Power loss nominal load max. | 15 W |
| Rise time | < 0.1 s (UOUT (10 % ... 90 %)) |
| Connection in parallel | yes, for redundancy and increased capacity |
| Connection in series | yes |
| Fuse protection (secondary side) | electronic |
| thermal-magnetic | |
| thermal | |
| Signal: DC OK active | |
| Output description | UOUT > 0.9 x UN: High signal |
| Switching voltage range | 18 V DC ... 24 V DC |
| Maximum inrush current | 20 mA (short-circuit-proof) |
| Continuous load current | ≤ 20 mA |
| Signal: DC OK floating | |
| Output description | Relay contact, UOUT > 0.9 x UN: Contact closed |
| Maximum switching voltage | 30 V AC |
| 24 V DC | |
| Maximum inrush current | 0.5 A (ATEX/IECEx: Ohmic loads only) |
| 1 A (ATEX/IECEx: Ohmic loads only) | |
| Continuous load current | 1 A |
| Signal: POWER BOOST, active | |
| Output description | IOUT < IN: High signal |
| Switching voltage range | 18 V DC ... 24 V DC |
| Output voltage | + 24 V DC |
| Maximum inrush current | 20 mA (short-circuit-proof) |
| Continuous load current | ≤ 20 mA |