MTL7761PAC | Eaton MTL Dual Channel 4-20mA Zener Intrinsic Safety Barrier Ex ia DIN Rail
The MTL7761PAC is a high-performance 2-channel shunt-diode safety barrier (Zener barrier) from Eaton's Crouse-Hinds series MTL7700 range, specifically engineered for strain-gauge bridge circuits, load cells, and Wheatstone bridge applications requiring intrinsic safety protection in hazardous areas.
Model Number Decoding: MTL7761PAC
| Code Segment |
Meaning |
| MTL |
MTL Instruments Group (now Eaton) |
| 77 |
MTL7700 series — Shunt-diode safety barriers |
| 61 |
Specific barrier configuration for strain-gauge bridges |
| PAC |
Power bus version with AC compatibility — for bussed power applications |
The "PAC" suffix indicates the power bus version, distinguishing it from the standard MTL7761AC model. This variant is designed for use with bussed power feed systems, reducing cabling requirements.
Key Features & Benefits
- 2-Channel Efficiency: Two independent intrinsically safe channels in a single compact housing — protects two field devices while using minimal panel space
- Strain-Gauge Bridge Optimization: Specifically designed for strain-gauge bridge circuits and load cell applications — provides the precise voltage and current limiting required for Wheatstone bridge measurements in hazardous areas
- 9 V Working Voltage: Provides safe voltage limiting for strain-gauge bridge circuits, preventing ignition under fault conditions
- 350 Ω End-to-End Resistance: Matches the impedance requirements of typical strain-gauge bridge circuits and load cells
- 26 mA Maximum Current: Adequate current handling for strain-gauge bridge excitation and signal measurement
- Power Bus (PAC) Capability: The PAC version integrates with MTL7798 power feed module for bussed power distribution — reduces cabling requirements and installation costs
- Removable Terminals: Unique removable terminal blocks for easy cabling and maintenance — simplifies installation and replacement without rewiring
- Ultra-Slim DIN Rail Mounting: Compact 12.6 mm width for standard 35 mm DIN rail installation, saving valuable panel space
- Angled Wire Entry: Wire entry is angled to assist wiring within limited space enclosures
- Dual-Stage Protection: Two stages of pulse-tested Zener diodes and an 'infallible' terminating resistor ensure continued safety if either stage should fail. No active output current limiting circuits are employed — pure passive design for maximum reliability
- Wide Operating Temperature: Functions reliably from -20 °C to +60°C
Technical Specifications
General Specifications
| Parameter |
Value |
| Manufacturer |
Eaton (Crouse-Hinds series MTL) |
| Series |
MTL7700 Range |
| Product Model |
MTL7761PAC |
| Product Type |
Shunt-Diode Safety Barrier (Zener Barrier) |
| Number of Channels |
2 (dual-channel) |
| Polarity |
AC (non-polarized) |
Electrical Ratings
| Parameter |
Value |
| Working Voltage (Vwkg) |
9 V |
| Safety Description |
9 V, 350 Ω, 26 mA |
| End-to-End Resistance |
350 Ω |
| Maximum Current |
26 mA |
| Fuse Rating |
50 mA |
| Maximum End-to-End Resistance |
378 Ω |
Intrinsic Safety Output Parameters (Single Channel)
| Parameter |
Value |
| Maximum Voltage (Uo) |
9 V |
| Maximum Current (Io) |
100 mA |
| Maximum Power (Po) |
225 mW |
Hazardous Area Specifications
| Parameter |
Value |
| Maximum Voltage (Vmax) |
6.8 V |
| Gas Groups |
IIC, IIB, IIA |
| Zones |
Zone 0, 1, 2 |
| Equipment Protection Level (EPL) |
Ga, Gb, Gc |
| Certificate |
ATEX II (1) GD [Ex ia] IIC |
Mechanical Specifications
| Parameter |
Value |
| Width |
12 mm / 12.6 mm |
| Height |
86 mm / 90 mm |
| Depth |
105 mm |
| Weight |
103 g / 0.121 kg |
| Enclosure Material |
Polycarbonate |
| Mounting |
DIN rail (35 mm T-section) |
| Terminals |
Removable screw terminals |
Environmental Specifications
| Parameter |
Value |
| Minimum Operating Temperature |
-20°C |
| Maximum Operating Temperature |
+60°C |
| Degree of Protection |
IP20 |
Certifications & Approvals
| Certification |
Status |
Details |
| ATEX |
✅ Certified |
II (1) GD [Ex ia] IIC |
| IECEx |
✅ Certified |
International certification for explosive atmospheres |
| CCC Ex (China) |
✅ Certified |
Available upon request |
| RoHS |
✅ Compliant |
Lead-free |
Function Description
The MTL7761PAC is a passive shunt-diode safety barrier that operates on the Zener barrier principle. It limits both voltage and current that can be delivered to a hazardous area circuit under fault conditions.
How it works:
- Voltage limiting: Zener diodes clamp the output voltage to a safe level (9 V) if the safe-area voltage rises above normal operating levels
- Current limiting: A series resistor (350 Ω) limits fault current to a safe value (26 mA)
- Fusing: Internal 50 mA fuses provide backup protection under severe fault conditions — two stages of voltage limitation ensure continued safety if either stage should fail
- Grounding: The barrier requires a connection to a high-integrity earth ground to function properly
- No active output current limiting circuits are employed — pure passive design for maximum reliability
Bussed Power Feature (PAC version):
- When used in conjunction with the MTL7798 power feed module, the MTL7761PAC provides a fully protected, electronically fused supply to many barriers with no additional wiring required
- Bussed power reduces cabling requirements and installation costs
Signal flow:
Safe Area (Control Side) Hazardous Area (Field Side)
Indicator/Excitation ──► MTL7761PAC ──► Intrinsically safe circuit
9 V DC supply ──► (Voltage/Current limiting) ──► Strain-Gauge Bridge/Load Cell
(Zener diodes + 350Ω resistor + 50mA fuse)
[High-integrity earth ground required]
Applications
The MTL7761PAC is specifically designed for strain-gauge and load cell applications in hazardous area installations:
| Industry |
Application |
| Oil & Gas |
Tank level measurement using load cells on storage tanks in Zone 0/1 areas; pipeline strain monitoring |
| Chemical Processing |
Vessel weighing systems, hopper scales, and silo level monitoring in explosive atmospheres |
| Pharmaceutical |
Batch weighing systems for solvent handling equipment requiring Ex ia protection |
| Mining |
Conveyor belt weighing systems, bin level monitoring |
| Food & Beverage |
Tank weighing for flammable liquid storage (spirits, cooking oils, ethanol) |
| Marine & Offshore |
Cargo tank monitoring, mooring line tension measurement |
| Tension Control |
Web tension monitoring in printing and converting equipment |
Typical field devices connected:
- Strain-gauge bridge sensors (full Wheatstone bridge configuration)
- Load cells (compatible with 350 Ω bridges)
- Torque sensors
- Pressure sensors based on strain-gauge technology
- Weighing systems in hazardous areas
- Tension detectors
MTL7761PAC vs. Related MTL7700 Series Models
| Model |
Working Voltage |
Resistance |
Current |
Polarity |
Power Bus |
Primary Application |
| MTL7761PAC |
9 V |
350 Ω |
26 mA |
AC |
Yes |
Strain-gauge bridges with power bus |
| MTL7761AC |
9 V |
350 Ω |
26 mA |
AC |
No |
Strain-gauge bridges (standard) |
| MTL7764+ |
12 V |
1,000 Ω |
12 mA |
Positive (+) |
No |
Strain-gauge bridges (positive polarity) |
| MTL7764- |
12 V |
1,000 Ω |
12 mA |
Negative (-) |
No |
Strain-gauge bridges (negative polarity) |
| MTL7766PAC |
14 V |
300 Ω |
93 mA |
AC |
Yes |
Power supply for 350 Ω bridges |
| MTL7706+ |
28 V |
300 Ω |
93 mA |
Positive (+) |
No |
General purpose positive polarity |
Why Choose the MTL7761PAC?
- Optimized for Strain-Gauge Bridges — Unlike general-purpose safety barriers, the MTL7761PAC is specifically designed for strain-gauge bridge circuits and load cells, providing the precise 9 V, 350 Ω, 26 mA characteristics required for accurate measurement in hazardous areas.
- Power Bus Capability — The PAC version integrates with MTL7798 power feed module for bussed power distribution, significantly reducing cabling requirements and installation costs compared to standard barriers.
- 2-Channel Efficiency — With two independent channels in a single compact 12.6 mm housing, the MTL7761PAC protects two field devices while using minimal panel space.
- Unique Removable Terminals — Unlike competitors, the MTL7761PAC features removable terminal blocks that simplify cabling, maintenance, and barrier replacement without rewiring — a unique feature of the MTL7700 series.
- Angled Wire Entry — Wire entry is angled to assist wiring within limited space enclosures, making installation easier in crowded control cabinets.
- Dual-Stage Protection — Each channel contains two stages of pulse-tested Zener diodes and an 'infallible' terminating resistor. In the event of an electrical fault, the diodes limit voltage and the resistor limits current. The two stages of voltage limitation ensure continued safety if either stage should fail.
- Proven MTL7700 Series Reliability — The MTL7700 series has been the industry standard for shunt-diode safety barriers for decades, trusted globally for intrinsic safety applications. No active output current limiting circuits are employed — pure passive design for maximum reliability.
- Global Approvals — Certified for use in major industrial markets including ATEX (Europe) and IECEx (international), the MTL7761PAC simplifies global equipment standardization.
- Simple Installation — DIN rail mounting, clearly labeled terminals, removable terminal blocks, and compact 12.6 mm width make installation quick and intuitive.
Installation Information
| Parameter |
Detail |
| Mounting |
Standard 35 mm T-section DIN rail (EN 60715) |
| Terminals |
Removable screw terminals |
| Grounding |
Requires high-integrity earth ground connection (simultaneously made when clipping onto DIN rail) |
| Clearance |
Minimal — 12.6 mm width enables high-density installation |
| Operating Position |
Any orientation |
Important Installation Notes:
- A high-integrity earth ground connection is mandatory for proper Zener barrier operation
- Do not install in areas where condensation may occur
- The barrier must be installed in a safe area (non-hazardous location)
- Maximum cable parameters for IIC gas group apply to field wiring
- For bussed power applications, use with MTL7798 power feed module
Ordering Information
| Item |
Details |
| Part Number |
MTL7761PAC |
| Brand |
Eaton (Crouse-Hinds series MTL) |
| Product Family |
MTL7700 Range — Shunt-Diode Safety Barriers |
| Tariff Code |
85369095 |
| Weight |
0.121 kg (103 g) |
| Country of Origin |
India |
| Condition |
New, Original, Factory Sealed |
| Minimum Order Quantity |
1 piece |
| Warranty |
Manufacturer's standard warranty |
| Shipping |
Immediate dispatch via DHL, FedEx, UPS, TNT |
Contact our sales team for volume pricing, datasheet downloads, or technical application support.
Related Products from MTL7700 Series for Strain-Gauge Applications
| Model |
Function |
Description |
| MTL7761PAC |
Bridge Signal Barrier |
9 V, 350 Ω, 26 mA — power bus version for signal |
| MTL7761AC |
Bridge Signal Barrier |
9 V, 350 Ω, 26 mA — standard version |
| MTL7766PAC |
Bridge Power Supply |
14 V, 300 Ω — power bus version for 350 Ω bridge excitation |
| MTL7798 |
Power Feed Module |
Provides bussed power distribution for PAC series barriers |
| MTL7764+ |
Bridge Sense (Positive) |
12 V, 1,000 Ω, 12 mA — positive polarity sensing |
| MTL7706+ |
Single-Channel Barrier |
28 V, 93 mA, 300 Ω — general purpose positive polarity |
The MTL7700 series offers a complete range of shunt-diode safety barriers for all intrinsic safety applications.