Oxygen Analyser Ntron Microx-231 Gas Analysis Lambda-Probe for Industrial Process Boiler Heat Treatment Unit Environmental Engineering

Price Negotiable
Price: Inquire
MOQ: NO MOQ
Delivery Time: Inquire
Brand: EVOzuRun
Product Description

Product Details

The ceramic part of the lambda probe (solid electrolyte) has the shape of a tube closed on one side. The surface of the probe ceramic is provided on the inside and outside with a microporous platinum layer (the electrodes), which on the one hand has a decisive influence on the probe characteristics through a catalytic effect and on the other hand serves for contacting. On the part of the probe ceramic on the measuring gas side, there is a firmly adhering, highly porous ceramic layer above the platinum layer. This protective layer prevents the residues in the measuring gas from having an erosive effect on the catalytically active platinum layer. This gives the probe a high long-term stability.

The active probe ceramic (ZrO2) is heated from the inside by a ceramic heating element, so that the temperature of the probe ceramic is kept constant regardless of the measuring gas temperature. The ceramic heating element has a PTC characteristic, which leads to rapid heating and limits the power requirement. The connections of the heating element are completely decoupled from the probe signal voltage (R> = 30M-Ohm).

Application: Marine Inert Gas Systems / Waste Incineration / Boiler Online Oxygen Monitoring / Flue Gas Analysis/Industrial process/Heat treatment unit/Environmental engineering

Technical Data

Parameter Specification
Manufacturer Ntron, Ireland
Model Microx-231
Sensor Type LP Zirconia
Measurement Range 1 ppm–25% O₂, Auto-Ranging
Measurement Accuracy ±2% of Reading at 20°C
Power Supply Requirement 24 VDC
Response Time (T90) <10 Seconds
Warm-Up Time 3 Minutes
Sensor Life 3–5 Years
Relative Humidity 0–95% RH, Non-Condensing
Gas Temperature 600°C
Sample Gas Pressure Vented to Atmosphere During Operation or Calibration
Supply Voltage 24 VDC (Optional 220 VAC)
Signal Output 4–20 mA
Relay Outputs 3 Relays
Communication Interface RS-232
Process Connection M18 Thread (Optional KF40 Flange)
Ingress Protection IP54


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangzhou Zhuyou Auto Parts Co., Ltd.
Location Room 418, Haoquan Building, Jingtai Street ,Guangzhou,Guangdong,China
Contact Person Suxi

Request A Quote

Please check your email address.
Your message must be at least 20 characters.