TF-30D201 Zirconia Oxygen Analyzer for Industrial Semiconductor Atmosphere N2 Furnace Air Separation Unit 741934634 971351824

Price Negotiable
Price: Inquire
MOQ: NO MOQ
Delivery Time: Inquire
Brand: EVOzuRun
Product Description
Specification Details
Model TF-21D201 (TF-21 Sensor + DTF-201 Receiver)
Measuring Principle Zirconia type concentration cell method
Measuring Range Minimum: 0–10 ppm; Maximum: 0–25%. Any four ranges selectable with a fixed zero point. Output range configurable from 0–10 ppm to 0–100%.
Calibration Air-point calibration plus up to four additional points. Calibration available for each measurement range.
Analog Output DC 4–20 mA, non-isolated output, load resistance ≤600 Ω. Selectable DC 0–1 V / DC 0–5 V / DC 0–10 V, non-isolated output.
Sample & Calibration Gas Flow Rate 0.5 L/min
Accuracy — Repeatability ±1% FS for ranges below 0–1%; ±0.5% FS for 0–1% range and above.
Accuracy — Linearity ±3% FS for ranges below 0–100 ppm; ±2% FS for ranges below 0–1%; ±1% FS for 0–1% range and above.
Response Time ≤30 seconds for ranges below 0–1%; ≤10 seconds for 0–1% range and above. Based on 90% response when switching calibration gas.
Drift ≤±2% FS per week
Power Supply AC version: AC 100–240 V ±10%, 50/60 Hz, 50 VA. DC version: DC 24 V ±10%, 50 W.
Contact Input Range switching via voltage-free contact
Contact Output Open collector output, DC 25 V max., 50 mA. Four outputs. Selectable functions: Analyzer fault / Range echo-back 1 / Range echo-back 2 / Range echo-back 3 / Ready / High concentration alarm / Low concentration alarm.
Range Switching Local / Remote / Automatic range switching
Output Hold Function Selectable: No hold / User-defined value / Value recorded 5 seconds before fault occurrence. Output held during warm-up and analyzer fault when hold is enabled.
High/Low Concentration Alarm High and low alarms independently configurable from 0.0–9,990.0 ppm or 0.0–100.0%.
RS-232C Communication Function Transmits measurement status, error code, measurement range, and measured value. Communication cable: D-sub 9-pin, straight cable.


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangzhou Zhuyou Auto Parts Co., Ltd.
Location Room 418, Haoquan Building, Jingtai Street ,Guangzhou,Guangdong,China
Contact Person Suxi

Request A Quote

Please check your email address.
Your message must be at least 20 characters.