Single Loop Vehicle Detector 20KHz - 200KHz For High Speed Doors / Electric Gates

Price Negotiable
Price: Negotiable
MOQ: 10 units
Delivery Time: 10 Work days
Brand: JWSY
Product Description
▋Single-Loop Vehicle Detector

This product is an inductive loop vehicle detector. Its working principle is that the metal components of a vehicle will change the inductance value of the detection loop, and a microcontroller analyzes this change to determine the presence of a vehicle. It is mainly used to control electric gates, high-speed doors, barrier gates, and in any scenarios that require vehicle presence detection.

▋Technical Specifications

Product Model J-CJ101
Device Name Single-Loop Vehicle Detector
Voltage 12V AC/DC±10%;24V AC/DC±10%;115V AC±10%;230V AC±10%
Power <2VA
Relay Output 10A/250VAC
Frequency Range 20KHz to 200KHz
Response Time 50ns (Single Channel)
Signal Hold Time Unlimited (Factory Setting) or Customizable
Sensitivity 0.01% to 0.1%,3-level Adjustable
Detection Loop Inductance Limit: 40uH to 1000uH; ldeal: 80uH to 300uH
Detection Loop Lead Wire Optimal within 10m, Total Resistance <100,20 Twists per Meter
Operating Temperature -25°C to 70°C
Storage Temperature -40°C to 85°C
Relative Humidity <90%, No Condensation
Temperature Compensation Automatic Compensation, Max. 50°C/h
Connection Type 11-Pin DlN Rail Socket
Dimensions 41x78x85 mm (WxHxL)
Weight 250g
Protection Class IP30
Electromagnetic Compatibility (EMC) Complies with EN50081-1 & EN50082-2

 

 

▋Product precautions

  1. Select the shortest possible loop connecting wires at all times. Do not route them in the same conduit with power transmission wires. The parallel distance from power transmission wires must exceed 10 cm, and loop connecting wires between different detectors must also be kept separated. Connecting wires on both sides must be twisted more than 20 times per meter from the control box to the detector. Wires shall not extend beyond the trenches of adjacent loops and must be protected against mechanical damage.
 
CAUTION!
 
Disconnect the power supply before removing the housing.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen Jieweishi Technology Co., Ltd.
Location No. 49, DaKeng Road, Tongle Community, Baolong Street,Longgang District, Shenzhen, China
Contact Person Tina Ma

Request A Quote

Please check your email address.
Your message must be at least 20 characters.