The LEM ART Series Split Core Rogowski Coil is an accurate, reliable, and easy-to-install energy sensor designed for future Smart Cities. It offers a flexible, non-intrusive solution for AC current measurement with galvanic separation. Featuring patented Perfect Loop Technology, it minimizes positioning and external conductor influence, making it ideal for a wide range of applications including MV/LV substations, power metering, building sub-metering, power quality monitoring, and fault detection.

Product Attributes

  • Brand: LEM
  • Product Series: ART Series
  • Technology: Perfect Loop Technology
  • Certifications: IEC 61010-1, IEC 61010-2-32, IEC 61869-1, IEC 61869-2, IEC 61869-6, IEC 61869-10, UL 61010-1
  • Output Signal: 22.5 mV/kA
  • Case Material: V0 (According to UL 94)
  • IP Rating: IP57
  • Insulation: 1000 V Cat III PD2
  • Termination: 2 stripped wires
  • Intended Use: For use in electric/electronic equipment; not intended for outdoor use.

Technical Specifications

Parameter Symbol Unit ART-B22-D70 ART-B22-D125 ART-B22-D175 ART-B22-D300 Comment
Sensing Aperture Diameter mm 70 125 175 300
Output Cable Length m 1.5 (Other lengths available) 1.5 (Other lengths available) 1.5 (Other lengths available) 1.5 (Other lengths available) See page 8 for other lengths
Coil Diameter mm 6.1 6.1 6.1 6.1 Very flexible and thin coil
Ambient Operating Temperature TA C -40 to 80 -40 to 80 -40 to 80 -40 to 80
Accuracy Class 0.5 (IEC 61869-2) 0.5 (IEC 61869-2) 0.5 (IEC 61869-2) 0.5 (IEC 61869-2)
Rated Insulation Voltage V 1000 1000 1000 1000 Cat III PD2
Mass m g 124 130 138 155 (Cable length: 1.5 m)
Rated short-time thermal current Ith kA 300 @ 50 Hz 300 @ 50 Hz 300 @ 50 Hz 300 @ 50 Hz (2)
Rated transformation ratio kra kA/V 44.44 @ 50 Hz 44.44 @ 50 Hz 44.44 @ 50 Hz 44.44 @ 50 Hz
Frequency Bandwidth (3 dB) BW kHz 420 373 350 300 (3)
Phase displacement @ 50/60 Hz 0.004 0.004 0.004 0.004 (3, 4)
Ratio error (centered) % -0.5 to 0.5 -0.5 to 0.5 -0.5 to 0.5 -0.5 to 0.5 Class 0.5 accuracy according to IEC 61869-2
Ratio error (all positions) % -0.75 to 0.75 -0.75 to 0.75 -0.75 to 0.75 -0.75 to 0.75 (5) Including positioning error
Influence of external current I ext % 0.2 to 0.4 0.2 to 0.4 0.2 to 0.4 0.2 to 0.4 (6)

Notes:

  • 1) The Rogowski coil can measure any primary current as there is no saturation effect.
  • 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts).
  • 3) Frequency bandwidth and phase shift modeling schematic can be provided on request.
  • 4) Referring to the main phase offset of 90 (a Rogowski coil is a derivative current transducer).
  • 5) Considering a primary conductor of at least 15 mm, perpendicular and in contact with the Rogowski coil.
  • 6) Considering an external conductor of at least 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Changsha Purple Horn E-Commerce Co., Ltd.
Location 2332 Kaibin Commercial Plaza, No. 419 Shaoshan Middle Road, Shazitang Street, Yuhua District, Changsha City, Hunan Province
Contact Person Sellina

Request A Quote

Please check your email address.
Your message must be at least 20 characters.