Product Overview
The Pulse Electronics PA200xNL series offers high isolation power transformers designed for basic and operational insulation applications. These transformers provide 1500Vrms isolation (380Vrms continuous) and are suitable for operating frequencies of 50kHz and up. They are available with basic insulation featuring 1.4mm creepage and clearance, or operational insulation. The series is RoHS-compliant, indicated by the "NL" suffix.
Product Attributes
- Brand: Pulse Electronics
- RoHS Compliance: Yes (indicated by "NL" suffix)
- Packaging Options: Tape & Reel (add "T" suffix), Tube
Technical Specifications
| Part Number | Turns Ratio | Isolation (VRMS) | MAX 1 V*sec | Primary Inductance (H MIN) | Leakage 2 Inductance (H MAX) | DCR Primary ( MAX) | DCR Secondary ( MAX) | Package Size (L x W x H) (mm MAX) | Weight (grams) | Tape & Reel (units/reel) | Tube (units/tube) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| OPERATIONAL INSULATION | |||||||||||
| PA2001NL | 1:1 | 1500 | 12 | 403 | 0.46 | 0.60 | 0.60 | 8.6 x 6.7 x 2.5 | 0.28 | 1500 | 60 |
| PA2002NL | 1:1:1 | 1500 | 60 | 1800 | 0.60 | 1.60 | 1.60 | 9.0 x 8.6 x 7.6 | 0.60 | 400 | 50 |
| PA2004NL | 1:1:1 | 1500 | 20 | 437 | 0.85 | 0.85 | 0.85 | 8.6 x 6.7 x 3.6 | 0.23 | 800 | 75 |
| BASIC INSULATION (1.4MM CREEPAGE AND CLEARANCE BETWEEN PRIMARY AND SECONDARY) | |||||||||||
| PA2005NL | 1:1:1 | 1500 | 26 | 840 | 0.75 | 1.05 | 1.05 | 11.8 x 8.8 x 4.0 | 0.48 | 900 | 60 |
| PA2006NL | 1:1 | 1500 | 26 | 864 | 0.75 | 0.82 | 0.82 | 11.8 x 8.8 x 4.0 | 0.48 | 900 | 60 |
| PA2007NL | 1:1 | 1500 | 53 | 1490 | 0.80 | 1.15 | 1.15 | 9.0 x 8.6 x 7.6 | 0.60 | 400 | 50 |
| PA2008NL | 2:1:1 | 1500 | 52 | 1425 | 0.80 | 1.15 | 0.575 | 9.0 x 8.6 x 7.6 | 0.60 | 400 | 50 |
| PA2009NL | 2.5:1:1 | 1500 | 47 | 1175 | 1.20 | 1.0 | 0.475 | 9.0 x 8.6 x 7.6 | 0.60 | 400 | 50 |
Notes:
- 1. The maximum volt-sec limits the peak flux density to 2800 Gauss when used in a unipolar drive application. For bi-polar drive applications, a maximum volt-sec of two times this rating is acceptable.
- 2. Leakage inductance is measured at primary terminals with all secondaries shorted.
- 5. The temperature of the component (ambient plus temperature rise) must be within the stated operating temperature range (-40C to 130C).
- 6. Continuous isolation voltage confirmed by 125C/1000hrs accelerated aging with the bias voltage applied between primary and secondary windings.