TE Schaffner IT253 pulse transformers featuring vacuum potting and PCB mounting for industrial applications
Pulse Transformers IT Series with Double Secondary Winding
The Pulse Transformers IT series with double secondary winding offers galvanic separation between drive and power circuits, providing voltage resistance up to 4 kV and ignition currents up to 1 A. These transformers are designed for various switching applications, power supplies, and data transmission, featuring vacuum potting for very low partial discharge effects and PCB through-hole mounting. Custom-specific versions are available upon request.
Product Attributes
- Brand: Schaffner
- Materials: UL 94 V-0 listed
- Certifications: UL 94 V-0
Technical Specifications
| Model | Turns Ratio | Ignition Current (Iign) [A] | Nominal Operating Voltage (Unom) [V] | Voltage Resistance (Up) [kV] | V0t [kVs] | Rise Time (tr) [s] | Primary Inductance (Lp) [mH] | Stray Inductance (Lstr) [H] | Resistance (Rp) [] | Resistance (Rs) [] | Capacitance (Ck) [pF] | Weight [g] |
| IT 143 | 1:1:1 | 0.025 | 500 | 4 | 800 | 0.6 | 15 | 200 | 3 | 3 | 10 | 2 |
| IT 242 | 1:1:1 | 0.1 | 500 | 3.2 | 250 | 0.9 | 2.5 | 75 | 0.75 | 0.75 | 7 | 6 |
| IT 243 | 1:1:1 | 0.1 | 500 | 3.2 | 250 | 1 | 2.5 | 85 | 0.8 | 0.8 | 7 | 6 |
| IT 213 | 1:1:1 | 0.25 | 380 | 2.5 | 450 | 0.4 | 6.5 | 20 | 1.4 | 1.4 | 40 | 9 |
| IT 233 | 1:1:1 | 0.25 | 500 | 4 | 300 | 1.3 | 3 | 45 | 0.8 | 0.8 | 7 | 13 |
| IT 253 | 1:1:1 | 0.25 | 500 | 3.2 | 160 | 1.3 | 1.1 | 45 | 0.55 | 0.55 | 6 | 6 |
| IT 312 | 1:1:1 | 0.25 | 380 | 2.5 | 1200 | 1 | 21 | 35 | 2.4 | 2.7 | 30 | 24 |
| IT 313 | 1:1:1 | 1 | 380 | 2.5 | 450 | 0.6 | 3 | 6 | 0.33 | 0.4 | 27 | 24 |
| IT 249 | 2:1:1 | 0.25 | 500 | 3.2 | 330 | 4 | 17 | 140 | 3.1 | 1.5 | 9 | 6 |
| IT 244 | 3:1:1 | 0.1 | 500 | 3.2 | 200 | 0.7 | 15 | 70 | 2.8 | 0.9 | 9 | 6 |
| IT 234 | 3:1:1 | 0.25 | 500 | 4 | 280 | 1 | 17 | 40 | 2 | 0.7 | 9 | 13 |
| IT 314 | 3:1:1 | 1 | 380 | 2.5 | 500 | 1 | 35 | 20 | 1.6 | 0.7 | 30 | 25 |
Note: Lp primary inductance measured at 1 kHz (secondary coil open). Lstr stray inductance measured at the secondary side, short circuit at the primary side. If there are several secondary coils, only one at a time is connected (measuring frequency 10 kHz). Tolerance for Lp: +50%; -30%.