Power distribution block Eaton PDB220-1 with UL listed status and 200 kA short circuit current rating

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

Product Overview

Eatons Bussmann series high Short-Circuit Current Rating (SCCR) power distribution blocks are designed to enhance compliance with National Electrical Code (NEC) and OSHA requirements by addressing common SCCR limitations in industrial control panels. These blocks offer up to 200 kA SCCR and are available in 1-, 2-, and 3-pole panel mount versions. They meet stringent UL 1953 spacing requirements for feeder circuit applications and field installations, ensuring safety by providing adequate separation between uninsulated opposite polarities or ground. The dual-wire rated ports accommodate copper or aluminum conductors, maintaining UL Listed status and increasing application flexibility. Optional covers are available for added electrical safety.

Product Attributes

  • Brand: Eatons Bussmann series
  • Certifications: UL Listed (UL 1953, Guide QPQS, File E256146), CSA Certified (Class 6228-01, File 47235)
  • Flammability Rating: UL 94 V0

Technical Specifications

Catalog SymbolNo. of PolesCurrent Rating (A)Lineside Wire Size (Str/ferrule unless noted)*Lineside Ports/poleLineside Torque Nm (Lb-in)Loadside Wire Size (Str/ferrule unless noted)*Loadside Ports/poleLoadside Torque Nm (Lb-in)Max SCCR (kA)**
PDB204-_1, 31752/0 - #1 Cu/Al (Str)112.4 (110)2/0 - #1 Cu/Al (Str)112.4 (110)200
PDB204-_1, 3175#2 - #3 Cu/Al1#2 - #3 Cu/Al1#4 - #8 Cu/Al1#4 - #8 Cu/Al1#10 - #12 Al (Str)14.0 (35)#10 - #12 Al (Str)14.0 (35)200
PDB204-_1, 3175#10 - #14 Cu1#10 - #14 Cu1#4 - #8 Cu/Al213.6 (120)#4 - #8 Cu/Al213.6 (120)200
PDB204-_1, 3175#10 - #14 Cu2#10 - #14 Cu2200
PDB220-_1, 31752/0 - #1 Cu/Al (Str)113.6 (120)#4 - #6 Cu/Al (Str)44.0 (35)200
PDB220-_1, 3175#2 - #3 Cu/Al1#8 Cu12.8 (25)#4 - #8 Cu/Al1-2#8 Al (Str)1-2#10 - #14 Cu1-22.3 (20)#10 - #14 Cu1-22.3 (20)200
PDB280-_1, 31752/0 - #1 Cu/Al (Str)113.6 (120)1/4-20 x 3/4 Stud1200
PDB280-_1, 3175#2 - #3 Cu/Al1#4 - #8 Cu/Al1-2#10 - #14 Cu1-2200
PDB321-_1, 2, 31752/0 - #1 Cu/Al (Str)113.6 (120)#4 - #6 Cu/Al (Str)64.0 (35)200
PDB321-_1, 2, 3175#2 - #3 Cu/Al1#8 Al (Str)1-2#4 - #8 Cu/Al1-2#8 Cu12.8 (25)#10 - #12 Al (Str)14.0 (35)#10 - #12 Al (Str)14.0 (35)200
PDB321-_1, 2, 3175#10 - #14 Cu1-2#10 - #14 Cu1-22.3 (20)200
PDB323-_1, 3310350kcmil - 2/0 Cu/Al (Str)131.1 (275)#4 - #6 Cu/Al (Str)64.0 (35)200
PDB323-_1, 3310#8 Al (Str)1-21/0 Cu/Al (Str)1-2#8 Cu12.8 (25)#1 - #6 Cu/Al1-2#10 - #12 Al (Str)14.0 (35)#10 - #12 Cu12.3 (20)200
PDB323-_1, 3310#10 - #14 Cu2200
PDB370-_1, 3310350kcmil - 2/0 Cu/Al (Str)131.1 (275)#4 - #6 Cu/Al (Str)124.0 (35)200
PDB370-_1, 33101/0 Cu/Al (Str)1-2#8 Al (Str)1-2#8 Cu12.8 (25)#1 - #6 Cu/Al1-2#10 - #12 Al (Str)14.0 (35)#10 - #14 Cu1-22.3 (20)200
PDB371-_1, 3310350kcmil - 2/0 Cu/Al (Str)131.1 (275)#2 - #3 Cu/Al (Str)65.6 (50)200
PDB371-_1, 3310#4 - #8 Al (Str)1#6 - #8 Al (Str)2#4 Cu15.1 (45)#6 Cu1-21/0 Cu/Al (Str)1-2#8 Cu/Al14.5 (40)200
PDB371-_1, 3310#10 - #12 Cu14.0 (35)#14 Cu2200
PDB371-_1, 33101/0 - #3 Cu/Al (Str)15.6 (50)#4 - #6 Cu/Al35.1 (45)#1 - #6 Cu/Al1-2#8 Cu/Al14.5 (40)#10 - #12 Cu14.0 (35)200
PDB371-_1, 3310#6 - #14 Cu213.6 (120)#4 - #6 Al (Str)2*200

* 75C wire (higher temperature rated wire acceptable with appropriate derating). Using a ferrule on a stranded conductor requires a correctly sized UL Listed ferrule (customer supplied) applied according to the manufacturers specifications. Ferrule ratings apply to copper wire only.
** See pages 4 and 5 for the tested upstream overcurrent protective devices necessary for achieving these SCCRs.
Torque rating for dual wire and ferrule application is 30.5 Nm (270 Lb-in).
Torque rating for ferrule application is 13.6 Nm (120 Lb-in).


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Hefei Purple Horn E-Commerce Co., Ltd.
Location Room 1306B, Building A, Xindi Center, Qimen Road, Hefei City, Anhui Province
Contact Person Sellina

Request A Quote

Please check your email address.
Your message must be at least 20 characters.