Product Description

Eaton Bussmann Stud Blocks

Eatons Bussmann series port-to-stud and stud-to-stud power terminal blocks offer a convenient solution for lug/ring wire terminals with current ratings up to 760 A. These blocks are designed for easy field wiring and are UL Recognized to UL 1059 and rated for use in UL 508A industrial control panels. They are factory configured from 1- to 3-poles, with optional covers available separately.

Product Attributes

  • Brand: Eaton Bussmann
  • Certifications: UL Recognized to UL 1059 (Guide XCFR2, File E62622), CSA Certified (Class 6228-01, File 15364)
  • Flammability Rating: UL 94 V0

Technical Specifications

Catalog SymbolNo. of PolesCurrent Rating (A)Lineside Conductor / Wire SizeLoadside Connection / Stud SizeSCCR (kA)Catalog Number ExampleTorque Nm (Lb-in)Ports/PoleStuds/Pole
162__1, 2, 31752/0 - #1 Cu/Al (Str)1/4-20 x 3/4 stud20016280-_**13.6 (120)11
162__-M2, 31752/0 - #1 Cu/Al (Str)M6 x 1 stud20016280-_-M13.6 (120)11
16281-_1, 2, 31752/0 - #1 Cu/Al (Str)1/4-20 tapped hole1016281-_**13.6 (120)11
16378-_1, 2, 3380500 kcmil - 4/0 Cu/Al (Str)1/4-20 x 1 stud1016378-_56.5 (500)21
16383-_1, 2, 3380500 kcmil - 4/0 Cu/Al (Str)3/8-16 x 1 stud1016383-_56.5 (500)11
16582-_1, 2, 3760500 kcmil - 4/0 Cu/Al (Str)3/8-16 x 1-5/8 stud1016582-_56.5 (500)22
16290-_1, 2, 3175Stud - to - stud1/4-20 x 3/4 stud1016290-_**N/A11
16390-_1, 2, 3250Stud - to - stud3/8-16 x 1-1/8 stud1016390-_N/A11
16395-_1, 2, 3310Stud - to - stud1/4-20 x 9/16 stud1016395-_N/A21
16392-_-H1, 2, 3400Stud - to - stud1/2-13 x 1-1/16 stud1016392-_-HN/A11
16394-_1, 2, 3400Stud - to - stud3/8-16 x 1-7/16 stud1016394-_N/A21
16591-_**1, 2, 3400Stud - to - stud3/8-16 x 1-7/16 stud1016591-_**N/A22
16593-_1, 2, 3600Stud - to - stud1/2-13 x 1 stud1016593-_N/A11

* 75C wire (higher temperature rated wire acceptable with appropriate derating). Using a ferrule on a stranded conductor requires a correctly sized UL Listed ferrule (customer supplied) applied according to the manufacturers specifications. Ferrule ratings apply to copper wire only.
** Not covered by CSA certification.
See table on next page for the tested upstream overcurrent protective devices necessary for achieving this SCCR.
Configuration includes washers and hex nuts for each stud.


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Hefei Purple Horn E-Commerce Co., Ltd.
Location Room 1306B, Building A, Xindi Center, Qimen Road, Hefei City, Anhui Province
Contact Person Sellina

Request A Quote

Please check your email address.
Your message must be at least 20 characters.